Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil

Product Details
Customization: Available
Type: Fan Coil Unit
Air Tube Material: Galvanized Sheet Casing, ABS Air Grille
Still deciding? Get samples of US$ 150/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
  • Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil
  • Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil
  • Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil
  • Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil
  • Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil
  • Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil
Find Similar Products

Basic Info.

Model NO.
EST-HE/VE series
Operating Voltage
110V/220~240V-50Hz/60Hz-1pH
Noise Level
Low
Application Fields
Restaurant/Hotel Room/Meeting Room/Office
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
CE
Condition
New
Thermostat
0~10V Stepless (3 Speed Control Is Optional)
Motor
DC,Ec
Installation
Ceiling Mounted /Floor Standing
Production Time
20 Days for Bulk Order
Air Return
Front/Downward
Pipe System
Two Pipe and Four Pipe System
Main Usage
Chiller, Heat Pump, Underfloor Heating
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Trademark
ESACIR
Origin
Guangdong, Prc.
HS Code
8415830000
Production Capacity
10000 PCS/Year

Product Description

Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil 

1. Ceiling exposed floor standing DC fan coil features

(1)Adopt famous branded high quality BLDC motor,high efficiency and low energy consumption;DC motor energy consumption is average less than 60% of AC motor.
(2)With long running life: as common AC motor is low operating efficiency,usually only 40~45% power consumption turn into kinetic energy,that means balance 55~60% energy is converted into heat,this heat may cause aging to motor components,which is harm to the motor life.DC brushless motor efficiency is always more than 80~95%,so only little energy changes to heat to prevent motor aging.
(3)Fast cooling/heating,temperature fluctuation is small,more comfortable.
a. If temperature difference between room temperature and setting temperature is big:
for normal AC style FCU,the fan will run under the setting speed;while the DC style will automatically run at high speed to make the room temperature to the setting temperature.
b. When the room temperature reach the setting temperature,the AC style fan coil will stop the fan running or close the water valve,this will cause the cooling/heating can not continue and there is temperature shock in the room;while the DC style fan coil will change its running speed according to the temperature difference between room temperature and setting temperature:if the distance is big, the fan speed will be higher,and if the distance is smaller ,the fan speed will be lower.
Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil
Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil
2. Ceiling exposed floor standing fan coil configuration
Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil

3. Ceiling exposed floor standing DC fan coil types
Four style universal fan coil unit can be selected:
Horizontal ceiling type with air return from downward without supporting legs
Floor standing type with air return from front with supporting legs
Horizontal ceiling type with air return from backward without supporting legs
Floor standing type with air return from bottom with supporting legs
Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil

4. DC Ceiling exposed fan coil unit main components
(1) Fan 

Fans are double inlets multi-blade centrifugal type. All fans are statically and dynamically balanced.
(2) Motor
Single-phase motors are suitable for different voltages, such as 110V, 115V, 120V, 220V, 230V, 240V. All motors have 10 percent voltage utilization range and wired to unit terminal box. Motors are designed for long life.
(3) Drain pan
Drain tray is made of plastic with hollow inside L shape and cover the entire coil.
(4) Water coil
Coils are standard design together with rows. High efficient hydrophilic aluminum fins are mechanically bonded to seamless copper tubes. All coils are specifically designed and circuited for water use. All coils are tested at 3.3MPa.
(5) Casing
Casing are constructed of heavy gauge steel. Air outlet grille and return air grille is ABS material for easy maintenance.
Units are furnished as standard with a 1 inch duct collar to facilitate connection of the supply air duct.
(6) Return air plenum 
The fan coil unit shall be factory installed return air plenum that encloses the fan section of the unit. No field fabrication is required. The return air arrangement is adaptable between bottom or front return of the plenum.
(7) Washable filter
Filter should be accessible from return air grille.

Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil

 
5. Eurostars Fan coil unit series
Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil
1 Ceiling concealed fan coil unit
2 High ESP ducted fan coil unit
3 Universal concealed fan coil unit
4 Floor standing exposed fan coil unit
5 Ultra thin exposed fan coil unit
6 Ceiling exposed fan coil unit
7 Ceiling cassette fan coil unit
8 Ceiling exposed & floor standing fan coil unit
9 Wall mounted fan coil unit

6. Ceiling floor standing exposed fan coil unit specification (DC motor)
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com

 
Universal Exposed Fan Coil Unit(2 pipe system)
Model   EST 200HE2 300HE2 400HE2 500HE2 600HE2 800HE2 1000HE2 1200HE2 1400HE2
200VE2 300VE2 400VE2 500VE2 600VE2 800VE2 1000VE2 1200VE2 1400VE2
Power supply 220V/1PH/50HZ
Air flow
 (m3/h)
H 340 510 680 850 1020 1360 1700 2040 2380
M / / / / / / / / /
L 120 160 220 270 330 420 570 670 760
Cooling capacity TH H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
SH W 1368 2052 2736 3420 4103 5471 6839 8207 9575
TH M W / / / / / / / / /
SH W / / / / / / / / /
TH L W 826 1101 1514 1858 2271 2891 3923 4611 5231
SH W 516 688 946 1161 1419 1807 2452 2882 3269
Heating capacity H W 2700 4050 5400 6750 8100 10800 13500 16200 18900
M W / / / / / / / / /
L W 1239 1652 2271 2787 3407 4336 5884 6917 7846
Universal Exposed Fan Coil Unit(4 pipe system)
Model   EST 200HE4 300HE4 400HE4 500HE4 600HE4 800HE4 1000HE4 1200HE4 1400HE4
200VE4 300VE4 400VE4 500VE4 600VE4 800VE4 1000VE4 1200VE4 1400VE4
Power supply 220V/1PH/50HZ
Air flow
 (m3/h)
MAX 340 510 680 850 1020 1360 1700 2040 2380
/ / / / / / / / / /
MIN 120 160 220 270 330 420 570 670 760
Cooling capacity TH H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
SH W 1368 2052 2736 3420 4103 5471 6839 8207 9575
/ / / / / / / / / / / /
/ / / / / / / / / / /
TH L W 826 1101 1514 1858 2271 2891 3923 4611 5231
SH W 516 688 946 1161 1419 1807 2452 2882 3269
Heating capacity MAX W 1300 1940 2590 3240 3890 5180 6480 7780 9070
/ / / / / / / / / / /
MIN W 596 791 1089 1338 1636 2080 2825 3322 3765

Remarks:
(1)  Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)  Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature  60°C/50ºC.

 
7.Why choose EUROSTARS?  
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Webiste 1: http://eurostarschiller.en.made-in-china.com/
Website 2: http://eurostarschiller.en.made-in-china.com/
 
Instagram: https://eurostarschiller.en.made-in-china.com
Facebook: https://eurostarschiller.en.made-in-china.com
Youtube https://eurostarschiller.en.made-in-china.com

Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.

Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil

8. Our fan coil production line
Every fan coil has strict production process, including assembly, testing, packing.

Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil
Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil

9. Our service and Customer visit
Before-sale services:
(1)Tell clients how to use our products and matters needing attention.
(2)Guide clients to choose the best and economic product, recover the investment within short time.
(3)Site inspection if client require.

In-sale services:
(1)Quality control must be inspect strictly.
(2)In accordance with the agreements stipulated in the contract.

After-sale services
(1)If the project needs our installation guidance, we can send our engineer and translator. We can also send customers installation video to teach them how to fix and operate with our product.
(2)Usually, our product warranty is 12 months since BL date, within this warranty period, all parts broken will be responsible for our factory.

Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil

 
10. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil

11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..

Heat Pump Chiller Hydrophilic Exposed BLDC Motor Fan Coil

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier