Packaged Rooftop Heat Recovery Fresh Air Handling Unit

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
  • Packaged Rooftop Heat Recovery Fresh Air Handling Unit
  • Packaged Rooftop Heat Recovery Fresh Air Handling Unit
  • Packaged Rooftop Heat Recovery Fresh Air Handling Unit
  • Packaged Rooftop Heat Recovery Fresh Air Handling Unit
  • Packaged Rooftop Heat Recovery Fresh Air Handling Unit
  • Packaged Rooftop Heat Recovery Fresh Air Handling Unit
Find Similar Products

Basic Info.

Model NO.
EST25MU4
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
HVAC Air Conditioning
Mounting
Floor Standing
Lifetime
>20 years
Certification
ISO, CE
Condition
New
Ahu Construction
25mm/ 50mm/ 75mm Double Skin
Optional 2
Heat Recovery Wheel
Ahu Panels
Painted Steel, Gi, Ss Panels
Filters
Pre-Filter, Bag Filter, HEPA Filter
Side Sliding Filter with Tracks
Yes
Cooling/ Heating Coil 2
Copper Tube with Copper Fins (Cu/Cu), Gi/SUS Frame
Control
Option for PLC, Ddc
Cooling/ Heating Coil 1
Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr
Optional 1
VSD, VFD
Fan
Belt Drive Centrifugal Fan, Plug Fan, Ec Fan
PU Foam Insulation
43-48kg/M3
Cold Bridge Free Design
Yes
Ahu Framework
Aluminum
Base
C-Channel Hot DIP Base
Optional 3
Ep, Chemical Filter, Plasma Sterilizer, Ak
Transport Package
Standard Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8415830000
Production Capacity
2000pieces/Year

Product Description

1.Eurostars air handling unit and air handler features
1). Working principle
--Both supply fan and exhaust fan are built inside to bring in fresh air and exhaust out the stale indoor air as well, thus to keep indoor space in natural comfort.
--Built-in heat exchanger (rotary heat exchanger or plate heat exchanger) transfers energy contained in the outgoing indoor air to the coming fresh air, thus fresh air is pre-cooled or preheated.
--Various functional sections such as filter section, cooling/heating section, humidifying section etc. can be combined together to meet different air treatment requirements.

2). Main features
Up-down layer construction, concise, compact.
Rotary heat exchanger(RHE) as a basic part. Humidifying section, coil section etc. selectable as per requirements.

3). Combination :RHE + coarse/medium filter + mix air + cooling/heating coil + fans

Packaged Rooftop Heat Recovery Fresh Air Handling Unit
2.Eurostars Air handler,air handling unit, ahu application
EUROSTARS air handling unit can cool, dry, heat, humidify, filter and purify air with silencer function. It can be widely applied in the places where the air needs to be conditioned in a centralized way, such as shopping malls, hotels, office buildings and stadiums, as well as other purification air-conditioning places, such as hospital operating rooms, pharmaceutical, tobacco, food, precision instruments manufacturing rooms.

3.Air handler technical data, Assembly drawing diagram and photo
Modular Air Handling Unit
Model
EST
4R 4MU4 6MU4 9MU4 12MU4 15MU4 18MU4 22MU4 25MU4 30MU4 35MU4 40MU4 45MU4 50MU4
6R 4MU6 6MU6 9MU6 12MU6 15MU6 18MU6 22MU6 25MU6 30MU6 35MU6 40MU6 45MU6 50MU6
Air Flow *1000CMH 4 6 9 12 15 18 22 25 30 35 40 45 50
Cooling
Coil Section
Sensible Capa.
(KW)/4R
26 40 58 76 102 121 131 174 201 235 274 308 348
Sensible Capa.
(KW)/6R
32 49 77 94 122 146 185 218 258 302 349 383 433
Heating Section E-Heating Capa.
(KW)
12 18 30 36 45 54 60 72 72 90 90 108 108
Humidifying Section Humidifying
Capa.(Kg/h)
5 10 13 15 15 25 30 45 45 60 60 60 75
Fan-motor
Section
ESP(Pa) 600 600 600 600 600 600 800 800 800 800 800 800 800
Motor Power(KW) 2.2 4 5.5 7.5 11 11 15 15 18.5 18.5 22 30 30
Mixing Section
Pre-filter Section
Cooling Coil Section
Eliminator Section
Elec-heating Section
Humidifying Section
Fan-motor Section
Diffusing Section
Medium-filter Section
Supply Air Section
NOTE:
  1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC;
  2. Technical parameters are subject to be revised without prior notice.
Packaged Rooftop Heat Recovery Fresh Air Handling Unit
4.Eurostars air handling unit , air handler range or series
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modular Modulus Air Handling Unit-multi-function air handling unit
Packaged Rooftop Heat Recovery Fresh Air Handling Unit
5.Components-air handling unit or air handler

Casing Panel and Insulation
• Double skin construction is provided by sandwich type panels comprising inner and outer painted steel skins and polyurethane foam with minimum 48kg/m3 density, providing a good thermal and acoustical performance
• The gasket liner between the panels and frame ensures the air leakage rate to comply with GB/T 14294 clean air conditioning requirement
• The factory painted steel sheet covered with 6 insulation coatings, complies to 500h salt spray testing, showing an excellent corrosion protection performance

Frame
•Penta-post extra heavy gauge aluminum profiles and strong fiber-reinforced PE corner connection forming the structural  frame
• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation
• Thermal bridge free design, the profiles filled with polyurethane foam for insulation
• Anodizing surface treatment for profiles, corrosion-resistant
• Stainless steel frame available

Sight Glass Service Door
• Double skin structure, inner panel is made of stainless steel, and outer panel is made of painted steel sheet
• Positive and negative access door, ensures the airtight of unit
• Convenient to check the running status of the unit
• Double sealing, no air leakage
• Built-in multi-point fastening locks make the panel evenly stressed, preventing air leakage and loss of energy efficiency of the unit

Hot-Dip Galvanized Base channel
Offer Rigid Base Channel protect unit and save installation cost

Fan and motor
•NICOTRA centrifugal Fan or other brand fan;
•Double inlet
•Electric motor driven
•Back curved or front curved
•low noise, high efficiency, stable operation, low vibration, good strength, low bearing temperature rise, and wide working temperature and humidity range.
•Customized configuration of the motor selected high-quality brand-name motor, smooth operation, low noise, long service life, and can be equipped with a specified brand of motor or motor insulation, protection level people according to user requirements, to meet the needs of different occasions.
•EC Fan is optional
• plug fan is optional
Packaged Rooftop Heat Recovery Fresh Air Handling Unit
Vibration Eliminator
• To reduce the transmission of vibration and noise, fan and motor are installed on an independent complete base frame
• The complete base frame is isolated by deflection type spring isolators
• This unique structure not only reduce the vibration and noise, but also protect fan and motor during transportation

Cooling Coil
Cooling Coil is used to cool and dehumidify the air.Both DX (direct expansion) cooling and CW (chilled water) cooling coils are available for use depending on the system design.
These coils are arranged in rows with different fin spacing.Aluminum fins and copper tubes are used in the design of the coils.The corrosion resistance hydrophilic fins are also
used due to its lower cost and lower resistance to the air velocity.
Packaged Rooftop Heat Recovery Fresh Air Handling Unit
PTC Electric Heating
•Constant temperature heating
•Virtually unlimited life
•Low electricity consumption and very low in cost
•No electrical noise
•The higher the temperature, the more electricity efficient
•Avoid burning when in contact with combustible materials
Packaged Rooftop Heat Recovery Fresh Air Handling Unit

Electrostatic Precipitator(optional)
• Adsorb and remove particles less than 0.01 micron in the air
• Improve indoor air quality 
• ESP applies energy only to the particulate matter being collected and therefore is very efficient in its consumption of energy

Electrode Humidifier
•Cylinder monitor system ensures more efficiency, better energy saving and stable result
•Drainage pump ensures the humidifying process accurate and stable
•Clog protection system ensures to avoid water overflow
•Water temperature control system makes sure the drainage pipe won't be damaged by hot water
•Anti-electric leakage system makes operation and maintenance safe and secure
Packaged Rooftop Heat Recovery Fresh Air Handling Unit
Filters

Filters are to remove particles and contaminants of various sizes from the air. The type of air filter being used will very much depend on the application of the system.
Panel Filter is a flat and rectangular in shape and provides a minimum low efficiency filtration which is acceptable to the air conditioning industry. The high velocity filter
is arranged vertically whereas the low velocity filter is arranged in V shape. Typical air velocity that moves through the filters is in the range of 2-3 m/s.

HEPA Filter is very efficient and is able to achieve efficiencies up to 99.97%, removing minute particles and airborne bacteria from the air. It is usually used in clean room
applications such as semiconductor production floor, operating theaters and critical processes.

Electrostatic Filter is used to remove particles from the air by using highly charged electrodes that ionized the air.
Bag Filter is able to remove dust particles and is thrown away after use.
Roll Filter is used for high velocity filtration where the used part is rolled up automatically/manually.
Packaged Rooftop Heat Recovery Fresh Air Handling Unit

Differential pressure meter Brand name:PRECISE
Differential pressure meter( with signal transfer) can be configured acccording to user requirements. 

Air damper
•Variable discharge air volume
•Discharge damper with axial fan, independent control
•High efficiency
•Manual damper available

Heat Wheel Heat Exchanger(optional)
• Highly efficient energy-saving rotary heat exchanger
• Energy recovery rates between 70-90%
• Summer application is dehumidification of warm and humid supply air to reduce the energy consumption of the down stream cooling equipment. 
• Winter operation recovers moisture from the exhaust air to reduce the humidification load.

Stainless Steel Drain Pan
• Slop type design, no drain water carryover and keep the pan dry
• Avoid the micro-organisms growth inside the drain pan
Antimicrobial Drain Pan is offered as option
• SteriTouch technology Drip Pan Coating
• Antimicrobial surface
• Good exterior durability and corrosion resistance
• Excellent adhesion
• Non-toxic, comply with BS476 part 7

Electrical control cabinet(optioanl)
•According to the requirements and functions of the unit to design the control console or cabinet
•Auto control each section of the unit to make sure the temperature, humidity and cleaness
•High quality and international brand electrical elements
•DDC and PLC available

6.Why choose us?
Eurostars offers One Stop Solutions for:
•Pharmaceuticals industry
•Electronics industry
•Automobile industry
•Printing and food industry
•Commercial building
•VOC treatment and environment protection
•Indoor air quality
•Marine ventilation
Packaged Rooftop Heat Recovery Fresh Air Handling Unit
7.FAQ
1:Are you a factory?
--- Yes, we are a professional manufacturer for more than 13 years
2:How do you check the goods?

--- We inspect all the materials when they arrive, and have spot inspection during production process. All goods will be tested and double inspected before delivery, providing 100% guarantee for clients.

3:How to select the suitable models?
---The parameters above is just for your reference. We need you to provide us the air flow, ESP or TSP, cooling capacity, heating capacity or application for our team to design the suitable unit for you.


8.Customer visit us
Packaged Rooftop Heat Recovery Fresh Air Handling Unit
9.Air handling unit,air handler delivery or container loading
Packaged Rooftop Heat Recovery Fresh Air Handling Unit
10.Installation instruction or installation photo, project photos
Packaged Rooftop Heat Recovery Fresh Air Handling Unit

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier