Horizontal Concealed Ceiling Exposed Cassette Slim DC Fan Coil Unit
1. Ceiling concealed DC fan coil brief description
Backed by a team of skilled professionals, our enterprise is able to offer a wide range of fan coil unit that produces very less noise. Offered range is manufactured using finest quality raw material and advance technology under the strict industry laid norms. Our offered fan coil unit is available in different specifications and sizes as per the requirements of the clients.
Eurostars ceiling concealed fan coils can be installed in hotels, apartments, multi-room buildings, commercial office, school, hospital, shopping mall, villa, sauna room, subway station, etc.
2. Ceiling concealed slim DC fan coil unit main components
(1) Fan
Fans are made of plastic centrifugal type. All fans are statically and dynamically balanced.
(2) Motor
Single-phase motors are suitable for different voltages, such as 110V, 115V, 120V, 220V, 230V, 240V. All motors have 10 percent voltage utilization range and wired to unit terminal box. Motors are designed for long life.
(3) Drain pan
Dray pan is integrally attached to coil casings and ended with drain hose. All pans are made of foam.
(4) Water coil
Coils are 2 and 3-row as standard design together. High efficient hydrophilic aluminum fins are mechanically bonded to seamless copper tubes. All coils are specifically designed and circuited for water use. All coils are tested at 3.3MPa.
(5) Casing
Casing are constructed of heavy gauge steel. Interior surface of unit panels are acoustically and thermally insulated with polyethylene foam.
Units are furnished as standard with a 1 inch duct collar to facilitate connection of the supply air duct.
(6) Return air plenum (optional)
The fan coil unit shall be factory installed return air plenum that encloses the fan section of the unit. No field fabrication is required. The return air arrangement is adaptable between bottom or rear return of the plenum.
(7) Washable filter (optional)
Filter should be accessible from return air grille.
3. Ceiling concealed fan coil unit features
(1)200mm slim design, beautiful appearance, save the space of ceiling
The fan coil is only 200mm thickness, which is suitable to installed in a height-limited ceiling.
(2)Left/right pipe connection direction is optional
The water pipe connection direction can be customized, it will benefit to short the installation cost.
(3)Air return box is standard, and air direction can be exchange between side return and bottom return
(4)Use plastic fan, which can offer softer air flowing and reduce the noise level.
(5)Air volume range is from 200CFM to 700CFM, which is fully satisfy to the necessary of home using.
(6)High efficiency
Adopt good quality heat exchanger and fan, which is benefit to the heat exchanging capacity and efficiency.
(7)Drain pump is optional
750 mm lift drain pump is optional to built-in the fan coil, the controlling of drain pump is also built-in. Water float switch is standard for the fan coil which built-in drain pump to prevent the leaking of draining.
4. Ceiling horizontal concealed fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Type |
DC motor slim concealed fan coil |
Max air flow |
200~700CFM(EST200HC2~800HC2) |
Static pressure |
12Pa |
Cooling capacity |
2~6.3KW |
Heating capacity |
3.2~10.2KW |
Fan type |
Plastic centrifugal fan |
Motor |
DC motor |
Application |
Commercial buildings,Hotel, Villa, etc. |
5. Fan coil unit series
Ceiling concealed fan coil unit
High ESP ducted fan coil unit
Universal concealed fan coil unit
Floor standing exposed fan coil unit
Ultra thin exposed fan coil unit
Ceiling exposed fan coil unit
Ceiling cassette fan coil unit
Ceiling exposed & floor standing fan coil unit
Wall mounted fan coil unit
6.About us:
(1) With more certificate
(2) Professional team with over more than 10 years industry knowledge
(3) Oversea installation.
(4) Customer-made accepted.
(5) Diamond member of Made-In-China
(6) Audited supplier by SGS
7. How to choose the fan coil?
(1) Firstly need to know the application site, for example, hotel room generally choose ceiling concealed fan coil, restaurant generally choose ceiling cassette fan coil, it depends on site requirements.
(2) If need to calculate cooling capacity, please get the acreage data.
(3) Confirm the pipe system: 2 pipe or 4 pipe according to the cooling and heating source.
8.FAQ
Q: Can I have a sample for testing before ordering products?
A: Yes, you can. And you are warmly welcomed to visit our factory before PO.
Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
Q: How to properly install the fan coil unit?
A: We have very detailed user manual and installation instructions, also can be directly telephone or online video guidance.
9. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
10. Ceiling concealed fan coil installation instruction
(1) Air duct must be fireproof regulations for buildings.
(2) For horizontal air supply, N≥150 MM; if air duct is longer than 1 m, N≥200 mm.
(3) Size of M depends on air duct installation. Pressure loss of circulatory air must be consistent with outlet static pressure of the unit.
11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..