Clean Room Hygienic Modular Air Handling Unit

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
  • Clean Room Hygienic Modular Air Handling Unit
  • Clean Room Hygienic Modular Air Handling Unit
  • Clean Room Hygienic Modular Air Handling Unit
  • Clean Room Hygienic Modular Air Handling Unit
  • Clean Room Hygienic Modular Air Handling Unit
  • Clean Room Hygienic Modular Air Handling Unit
Find Similar Products

Basic Info.

Model NO.
EST6MU6
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Medicine
Mounting
Floor Standing
Lifetime
>20 years
Certification
ISO, CE
Condition
New
Ahu Construction
25mm/ 50mm/ 75mm Double Skin
Optional 1
VSD, VFD
Ahu Panels
Painted Steel, Gi, Ss Panels
Cooling/ Heating Coil 2
Copper Tube with Copper Fins (Cu/Cu), Gi/SUS Frame
Cooling/ Heating Coil 1
Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr
Fan
Belt Drive Centrifugal Fan, Plug Fan, Ec Fan
Control
Option for PLC, Ddc
Side Sliding Filter with Tracks
Yes
PU Foam Insulation
43-48kg/M3
Cold Bridge Free Design
Yes
Filters
Pre-Filter, Bag Filter, HEPA Filter
Ahu Framework
Aluminum
Base
C-Channel Hot DIP Base
Optional 2
Heat Recovery Wheel
Optional 3
Ep, Chemical Filter, Plasma Sterilizer, Ak
Transport Package
Standard Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8415830000
Production Capacity
2000pieces/Year

Product Description

1.Eurostars air handling unit and air handler features
1) Industrial cooling and heating terminal AHU, modular sections for your application, precise temp and RH% control.
2) Good components rigid AHU, double skin, penta post, cold bridge free, double sealing strip, low leakage, heavy duty bearing, high efficient fan, many type coil coating available, filter type you need, all configuration AHU discharge and intake.
3) Pharmaceutical 4Q AHU, heat recovery, temperature and RH% controlled, high static fan, PLC controller for BMS or local control starter. We supply over 60 pharmaceutical factories in domestic and oversea market.
 4) Full stainless steel AHU, for hygienical food and hospital, SS Casing, SS Coil, SS Fan; SS for everything in AHU.
5) Valuable AHU you look for. Good cooling and Heating,Low speed fan, lesser kW motor, longer life bearings, External drive fan, built-in Stainless steel drain pan. See the good price AHU in our factory.


2.Eurostars Air handler,air handling unit, ahu application
Eurostars air handlers widely used in stadium, exhibition centers, airport, large station, as well as in all kinds of factories, such as car, electronics, textile, medicine, tobacco, alternator, and precise instrument. 

3.Air handler technical data, Assembly drawing diagram and photo
Modular Air Handling Unit
Model
EST
4R 4MU4 6MU4 9MU4 12MU4 15MU4 18MU4 22MU4 25MU4 30MU4 35MU4 40MU4 45MU4 50MU4
6R 4MU6 6MU6 9MU6 12MU6 15MU6 18MU6 22MU6 25MU6 30MU6 35MU6 40MU6 45MU6 50MU6
Air Flow *1000CMH 4 6 9 12 15 18 22 25 30 35 40 45 50
Cooling
Coil Section
Sensible Capa.
(KW)/4R
26 40 58 76 102 121 131 174 201 235 274 308 348
Sensible Capa.
(KW)/6R
32 49 77 94 122 146 185 218 258 302 349 383 433
Heating Section E-Heating Capa.
(KW)
12 18 30 36 45 54 60 72 72 90 90 108 108
Humidifying Section Humidifying
Capa.(Kg/h)
5 10 13 15 15 25 30 45 45 60 60 60 75
Fan-motor
Section
ESP(Pa) 600 600 600 600 600 600 800 800 800 800 800 800 800
Motor Power(KW) 2.2 4 5.5 7.5 11 11 15 15 18.5 18.5 22 30 30
Mixing Section
Pre-filter Section
Cooling Coil Section
Eliminator Section
Elec-heating Section
Humidifying Section
Fan-motor Section
Diffusing Section
Medium-filter Section
Supply Air Section
NOTE:
  1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC;
  2. Technical parameters are subject to be revised without prior notice.
Clean Room Hygienic Modular Air Handling Unit
4.Eurostars air handling unit , air handler range or series
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modular Modulus Air Handling Unit-multi-function air handling unit
Clean Room Hygienic Modular Air Handling Unit
5.Components-air handling unit or air handler

Casing Panel and Insulation
• Double skin construction is provided by sandwich type panels comprising inner and outer painted steel skins and polyurethane foam with minimum 48kg/m3 density, providing a good thermal and acoustical performance
• The gasket liner between the panels and frame ensures the air leakage rate to comply with GB/T 14294 clean air conditioning requirement
• The factory painted steel sheet covered with 6 insulation coatings, complies to 500h salt spray testing, showing an excellent corrosion protection performance

Frame
•Penta-post extra heavy gauge aluminum profiles and strong fiber-reinforced PE corner connection forming the structural  frame
• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation
• Thermal bridge free design, the profiles filled with polyurethane foam for insulation
• Anodizing surface treatment for profiles, corrosion-resistant
• Stainless steel frame available

Sight Glass Service Door
• Double skin structure, inner panel is made of stainless steel, and outer panel is made of painted steel sheet
• Positive and negative access door, ensures the airtight of unit
• Convenient to check the running status of the unit
• Double sealing, no air leakage
• Built-in multi-point fastening locks make the panel evenly stressed, preventing air leakage and loss of energy efficiency of the unit

Hot-Dip Galvanized Base channel
Offer Rigid Base Channel protect unit and save installation cost
Clean Room Hygienic Modular Air Handling Unit
Fan and motor
•NICOTRA centrifugal Fan or other brand fan;
•Double inlet
•Electric motor driven
•Back curved or front curved
•low noise, high efficiency, stable operation, low vibration, good strength, low bearing temperature rise, and wide working temperature and humidity range.
•Customized configuration of the motor selected high-quality brand-name motor, smooth operation, low noise, long service life, and can be equipped with a specified brand of motor or motor insulation, protection level people according to user requirements, to meet the needs of different occasions.
•EC Fan is optional
• plug fan is optional
Clean Room Hygienic Modular Air Handling Unit
Vibration Eliminator
• To reduce the transmission of vibration and noise, fan and motor are installed on an independent complete base frame
• The complete base frame is isolated by deflection type spring isolators
• This unique structure not only reduce the vibration and noise, but also protect fan and motor during transportation

Cooling Coil
Cooling Coil is used to cool and dehumidify the air.Both DX (direct expansion) cooling and CW (chilled water) cooling coils are available for use depending on the system design.
These coils are arranged in rows with different fin spacing.Aluminum fins and copper tubes are used in the design of the coils.The corrosion resistance hydrophilic fins are also
used due to its lower cost and lower resistance to the air velocity.
Clean Room Hygienic Modular Air Handling Unit
PTC Electric Heating
•Constant temperature heating
•Virtually unlimited life
•Low electricity consumption and very low in cost
•No electrical noise
•The higher the temperature, the more electricity efficient
•Avoid burning when in contact with combustible materials
Clean Room Hygienic Modular Air Handling Unit

Electrostatic Precipitator(optional)
• Adsorb and remove particles less than 0.01 micron in the air
• Improve indoor air quality 
• ESP applies energy only to the particulate matter being collected and therefore is very efficient in its consumption of energy

Electrode Humidifier
•Cylinder monitor system ensures more efficiency, better energy saving and stable result
•Drainage pump ensures the humidifying process accurate and stable
•Clog protection system ensures to avoid water overflow
•Water temperature control system makes sure the drainage pipe won't be damaged by hot water
•Anti-electric leakage system makes operation and maintenance safe and secure
Clean Room Hygienic Modular Air Handling Unit
Filters

Filters are to remove particles and contaminants of various sizes from the air. The type of air filter being used will very much depend on the application of the system.
Panel Filter is a flat and rectangular in shape and provides a minimum low efficiency filtration which is acceptable to the air conditioning industry. The high velocity filter
is arranged vertically whereas the low velocity filter is arranged in V shape. Typical air velocity that moves through the filters is in the range of 2-3 m/s.

HEPA Filter is very efficient and is able to achieve efficiencies up to 99.97%, removing minute particles and airborne bacteria from the air. It is usually used in clean room
applications such as semiconductor production floor, operating theaters and critical processes.

Electrostatic Filter is used to remove particles from the air by using highly charged electrodes that ionized the air.
Bag Filter is able to remove dust particles and is thrown away after use.
Roll Filter is used for high velocity filtration where the used part is rolled up automatically/manually.
Clean Room Hygienic Modular Air Handling Unit

Differential pressure meter Brand name:PRECISE
Differential pressure meter( with signal transfer) can be configured acccording to user requirements. 

Air damper
•Variable discharge air volume
•Discharge damper with axial fan, independent control
•High efficiency
•Manual damper available

Heat Wheel Heat Exchanger(optional)
• Highly efficient energy-saving rotary heat exchanger
• Energy recovery rates between 70-90%
• Summer application is dehumidification of warm and humid supply air to reduce the energy consumption of the down stream cooling equipment. 
• Winter operation recovers moisture from the exhaust air to reduce the humidification load.

Stainless Steel Drain Pan
• Slop type design, no drain water carryover and keep the pan dry
• Avoid the micro-organisms growth inside the drain pan
Antimicrobial Drain Pan is offered as option
• SteriTouch technology Drip Pan Coating
• Antimicrobial surface
• Good exterior durability and corrosion resistance
• Excellent adhesion
• Non-toxic, comply with BS476 part 7

Electrical control cabinet(optioanl)
•According to the requirements and functions of the unit to design the control console or cabinet
•Auto control each section of the unit to make sure the temperature, humidity and cleaness
•High quality and international brand electrical elements
•DDC and PLC available

6.Why choose us?
EUROSTARS Advantages: 
1) The Proof of Quality: Now we have customers in different countries and places, such as Mexico, Australia, New Zealand, Singapore, Argentina, Middle- East, Africa…
2) The Guarantee of Quality: Reasonable design, Professional technicians, Stable production workers, Full-scale
 Equipments, Strict QA & QC system…
3) Custom-made Design: We supply our design drawing according to customer practical situation
4) Technique Support: 
 Walk in cold room: we supply our diagrammatic drawing, feel easier for installation.
 Cold storage warehouse: We have professional engineers who can go aboard to supply technology support and direction, until  turn key for our customers. 
5)International Trade Operation: We have concentrated on international trade of cold storage room line for many years, accumulated various experience from different customers of different countries. So we can update our operation in time according to our customers and new rules. It is helpful to clear custom and save cost and time for our customers.
Clean Room Hygienic Modular Air Handling Unit
7.FAQ
Q:What are the differences between an air conditioner and an air handler?
Air handlers are an important part of your overall HVAC system, but they are not the complete air conditioning system.

An air handler is responsible for housing the equipment necessary to move air through your home or business.In most cases, it is located inside and operates both the heating and cooling systems.Air handlers look like a furnace, and are sometimes even mistaken for one.Air handlers can be made to work with a heat pump or air conditioner.It includes the indoor coil, which depending on the setting your system is running on, is used for both heating and cooling.

Air conditioning units include the condenser and are usually kept outside of your home or business.Air conditioners actively pull heat out of the building through a variety of components configured together, and then this hot air is redirected outside.Throughout the process, air moves through the system via return ducts and over a refrigerant coil.Instead of adding cold air to the room, which is what it feels like, the system is actually just pulling hot air out and then recirculating the same air (without the heat) back into the building.

8.Customer visit us
Clean Room Hygienic Modular Air Handling Unit
9.Air handling unit,air handler delivery or container loading
Clean Room Hygienic Modular Air Handling Unit
10.Installation instruction or installation photo, project photos
Clean Room Hygienic Modular Air Handling Unit

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier