Ultra Thin Concealed Fan Coil DC Motor Fan Coil Unit
1. Ceiling concealed slim DC fan coil brief description
Fan coil units are referred to as fan coils. It is one of the end devices of an air conditioning system consisting of a small fan, a motor and a coil (air heat exchanger). When the chilled water or hot water flows through the coil pipe, heat is exchanged with the air outside the pipe, the air is cooled, and the indoor air parameters are adjusted by dehumidifying or heating. It is a commonly used cooling and heating terminal device.
Type |
DC motor slim concealed fan coil |
Max air flow |
200~700CFM(EST200HC2~800HC2) |
Static pressure |
12Pa |
Cooling capacity |
2~6.3KW |
Heating capacity |
3.2~10.2KW |
Fan type |
Plastic centrifugal fan |
Motor |
DC motor |
Application |
Commercial buildings,Hotel, Villa, etc. |
2. Slim DC fan coil main applications
Showroom |
Shopping mall |
Restaurant & Bar |
Hotels |
Offices |
Building |
Clean room |
Library |
School |
Supermarket |
Exhibition hall |
Factory |
Apartments |
Dormitories |
3. Ceiling concealed slim DC fan coil unit main components
(1)Plastic fan
(2) DC Motor
(3) Foam drain pan
(4) Water coil
(5)Casing
(6) Optional return air plenum and filter
4. Ceiling concealed slim DC fan coil unit features
(1)200mm slim design, beautiful appearance, save the space of ceiling
The fan coil is only 200mm thickness, which is suitable to installed in a height-limited ceiling.
(2)Left/right pipe connection direction is optional
The water pipe connection direction can be customized, it will benefit to short the installation cost.
(3)Air return box is standard, and air direction can be exchange between side return and bottom return
(4)Use plastic fan, which can offer softer air flowing and reduce the noise level.
(5)Air volume range is from 200CFM to 700CFM, which is fully satisfy to the necessary of home using.
(6)High efficiency
Adopt good quality heat exchanger and fan, which is benefit to the heat exchanging capacity and efficiency.
(7)Drain pump is optional
750 mm lift drain pump is optional to built-in the fan coil, the controlling of drain pump is also built-in. Water float switch is standard for the fan coil which built-in drain pump to prevent the leaking of draining.
5. Fan coil unit series
Ceiling concealed fan coil unit
High ESP ducted fan coil unit
Universal concealed fan coil unit
Floor standing exposed fan coil unit
Ultra thin exposed fan coil unit
Ceiling exposed fan coil unit
Ceiling cassette fan coil unit
Ceiling exposed & floor standing fan coil unit
Wall mounted fan coil unit
6.About us:
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Webiste 1: http://eurostarschiller.en.made-in-china.com
Website 2: http://eurostarschiller.en.made-in-china.com
Instagram: https://eurostarschiller.en.made-in-china.com
Facebook: https://eurostarschiller.en.made-in-china.com
Youtube https://eurostarschiller.en.made-in-china.com
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
7. How to choose the fan coil?
(1) Firstly need to know the application site, for example, hotel room generally choose ceiling concealed fan coil, restaurant generally choose ceiling cassette fan coil, it depends on site requirements.
(2) If need to calculate cooling capacity, please get the acreage data.
(3) Confirm the pipe system: 2 pipe or 4 pipe according to the cooling and heating source.
8. Our warranty, technical support and failure claim procedures
(1) Warranty
a. Eurostars HVAC units delivered to customers are carefully examined and tested, with 48 hours trouble-free trial operation.
b. Eurostars HVAC units enjoy 1~1.5 years guarantee ever since B/L date.
(2)Technical support
a. Eurostars provide full technical support and training courses after equipment installation and commissioning.
b. 7*24 hours phone assistance on technical support.
c. Eurostars provide overseas guide installation,but not for free.
(3)Failure claim procedures
a. Detailed written failure description is required by fax or by mail, indicating the relevant equipment information and detailed description of failure.
b. Relevant pictures are required for failure confirmation.
c. Eurostars engineering and after-sales service team will check and form a diagnosis report.
d. Further trouble-shooting solutions will be offered to customers within 24 hours after receiving the written description and pictures.
9. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
10. Ceiling concealed fan coil installation instruction
(1) Air duct must be fireproof regulations for buildings.
(2) For horizontal air supply, N≥150 MM; if air duct is longer than 1 m, N≥200 mm.
(3) Size of M depends on air duct installation. Pressure loss of circulatory air must be consistent with outlet static pressure of the unit.
11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..