1. Horizontal concealed fan coil general description
Horizontal ceiling concealed fan coil units are designed specifically to meet many various requirements demanded for concealed type installation.
1) Showroom
(2) Shopping mall
(3) Restaurant & Bar
(4) Hotels
(5) Offices
(6) Building
(7) Clean room
(8) Other fieldsCommonly used for low static ( free blow or short duct ) application within the closets of motels and apartments.
2. Ceiling concealed fan coil unit main components
All fan coil units are completely factory packaged with blower fan, motor, chilled water coil, circuited and terminated pipe connections. Available for following models:
Cooling capacity: 1.8KW to 12.6KW
Heating capacity: 2.7KW to 18.9KW
Air flow: 200 CFM to 1400 CFM
3. Ceiling horizontal concealed fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Horizontal Concealed Fan Coil Unit (2 pipe system) | |||||||||||
Model EST~ | 200HC2 | 300HC2 | 400HC2 | 500HC2 | 600HC2 | 800HC2 | 1000HC2 | 1200HC2 | 1400HC2 | ||
Air flow (m3/h) (0/12Pa,30Pa Static Pressure) |
High | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | |
Medium | 270 | 380 | 515 | 660 | 765 | 1040 | 1280 | 1550 | 1800 | ||
Low | 190 | 260 | 340 | 430 | 530 | 710 | 860 | 1050 | 1280 | ||
Rated cooling capacity | H | TH(W) | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
SH(W) | 1341 | 2012 | 2682 | 3353 | 4023 | 5364 | 6705 | 8046 | 9387 | ||
M | TH(W) | 1485 | 2187 | 2916 | 3645 | 4374 | 5832 | 7290 | 8748 | 10206 | |
SH(W) | 1152 | 1728 | 2304 | 2880 | 3455 | 4607 | 5759 | 6911 | 8063 | ||
L | TH(W) | 1134 | 1701 | 2268 | 2835 | 3402 | 4536 | 5670 | 6804 | 7938 | |
SH(W) | 930 | 1395 | 1860 | 2325 | 2790 | 3720 | 4649 | 5579 | 6509 | ||
Rated heating capacity | H | W | 2700 | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 | 18900 |
M | 2079 | 3119 | 4158 | 5198 | 6237 | 8316 | 10395 | 12474 | 14553 | ||
L | 1634 | 2450 | 3267 | 4084 | 4901 | 6534 | 8168 | 9801 | 11435 |
Horizontal Concealed Fan Coil Unit (4 pipe system) | |||||||||||
Model EST~ | 200HC4 | 300HC4 | 400HC4 | 500HC4 | 600HC4 | 800HC4 | 1000HC4 | 1200HC4 | 1400HC4 | ||
Air flow (m3/h) (0/12Pa,30Pa Static Pressure) |
High | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | |
Medium | 270 | 380 | 515 | 660 | 765 | 1040 | 1280 | 1550 | 1800 | ||
Low | 190 | 260 | 340 | 430 | 530 | 710 | 860 | 1050 | 1280 | ||
Rated cooling capacity | H | TH(W) | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 |
SH(W) | 1341 | 2012 | 2682 | 3353 | 4023 | 5364 | 6705 | 8046 | 9387 | ||
M | TH(W) | 1485 | 2187 | 2916 | 3645 | 4374 | 5832 | 7290 | 8748 | 10206 | |
SH(W) | 1152 | 1728 | 2304 | 2880 | 3455 | 4607 | 5759 | 6911 | 8063 | ||
L | TH(W) | 1134 | 1701 | 2268 | 2835 | 3402 | 4536 | 5670 | 6804 | 7938 | |
SH(W) | 930 | 1395 | 1860 | 2325 | 2790 | 3720 | 4649 | 5579 | 6509 | ||
Rated heating capacity | H | W | 1080 | 1620 | 2160 | 2700 | 3240 | 4320 | 5400 | 6480 | 7560 |
M | 832 | 1248 | 1663 | 2079 | 2495 | 3326 | 4158 | 4990 | 5821 | ||
L | 654 | 980 | 1307 | 1634 | 1960 | 2614 | 3267 | 3920 | 4574 |