Slim Exposed Wall Mounted Fan Coil Unit With Built-in Thermostat
1. Ultra thin exposed floor standing fan coil brief introduction
Fan coil units are mainly composed of tangential fans and coil heat exchangers. It is the terminal device of the central air conditioning system. And the fan sends indoor air or outdoor mixed air through the air cooler to be cooled or heated and then sends the air into the room to lower or raise the indoor temperature to meet people's comfort requirements.
It is widely used in hotels, restaurants, factories, hospitals, exhibition galleries, shopping malls and moving buildings.It is used to meet the requirements of cooling, dehumidification, heating and so on.
Product name |
Ultra thin vertical exposed fan coils |
Cooling capacity |
1.015-3.615kW |
Heating capacity |
1.615-5.765kW |
DB/WB |
27ºC / 19.5ºC |
Model |
EST200UT2~EST600UT2 |
Airflow |
200,300,400,500,600 CMH |
Fan type |
Cross-flow |
Motor |
Plastic packaged |
Funtion |
Air Conditioner Terminal Unit |
Application |
Commercial builings,Hotel,Hospital, etc. |
2. Ultra thin exposed floor standing fan coil unit main components
Fan |
Cross-flowl type, pass statically and dynamically balanced test |
Motor |
Plastic sealed single-phase motors are suitable for different voltages |
Drain pan |
Condensate water drained out by the condensate pipe |
Coil |
Hydrophilic blue aluminium fin around with copper tube |
Housing |
Galvanized steel structure, aluminum alloy air grille |
Controller |
Built-in LED thermostat optional |
3. Slim exposed floor standing wall mounted fan coil features
(1)Less water loss
(2)Exquisite structure, beautiful appearance
(3)Electricity use, low noise, long life
(4)Design features: large wind wheel, low speed, small size, light weight
(5)Mechanical pipe expansion process, mechanical pipe bending process, gas protection automatic welding
4. Eurostars Fan coil unit series
1 |
Ceiling concealed fan coil unit |
2 |
High ESP ducted fan coil unit |
3 |
Universal concealed fan coil unit |
4 |
Floor standing exposed fan coil unit |
5 |
Ultra thin exposed fan coil unit |
6 |
Ceiling exposed fan coil unit |
7 |
Ceiling cassette fan coil unit |
8 |
Ceiling exposed & floor standing fan coil unit |
9 |
Wall mounted fan coil unit |
5. Slim floor standing exposed fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Vertical Exposed Fan Coil Unit(Ultra thin type) |
Model EST |
200UT2 |
300UT2 |
400UT2 |
500UT2 |
600UT2 |
Air flow (m³/h) |
H |
200 |
300 |
400 |
500 |
600 |
M |
150 |
220 |
300 |
380 |
450 |
L |
115 |
165 |
235 |
295 |
345 |
Rated cooling capacity |
W(H) |
1015 |
1815 |
2415 |
3015 |
3615 |
BTU(H) |
3464 |
6195 |
8242 |
10290 |
12338 |
W(M) |
815 |
1455 |
35 |
2415 |
2895 |
BTU(M) |
2782 |
4966 |
119 |
8242 |
9881 |
W(L) |
665 |
1185 |
1575 |
1965 |
2355 |
BTU(L) |
2270 |
4044 |
5375 |
6707 |
8038 |
Rated heating capacity |
W(H) |
1615 |
2915 |
3865 |
4815 |
5765 |
BTU(H) |
5512 |
9949 |
13191 |
16434 |
19676 |
W(M) |
1295 |
2335 |
3095 |
3855 |
4615 |
BTU(M) |
4420 |
7969 |
10563 |
13157 |
15751 |
W(L) |
845 |
1525 |
2015 |
2515 |
3005 |
BTU(L) |
2884 |
5205 |
6877 |
8584 |
10256 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
6. Ultra thin exposed fan coil unit construction parts
7. About EUROSTARS
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Webiste 1: http://eurostarschiller.en.made-in-china.com/
Website 2: http://eurostarschiller.en.made-in-china.com/
Instagram: https://eurostarschiller.en.made-in-china.com
Facebook: https://eurostarschiller.en.made-in-china.com
Youtube https://eurostarschiller.en.made-in-china.com
8. Our fan coil production line
Every fan coil has strict production process, including assembly, testing, packing.
9. How to choose the fan coil?
(1) Firstly need to know the application site, for example, hotel room generally choose ceiling concealed fan coil, restaurant generally choose ceiling cassette fan coil, it depends on site requirements.
(2) If need to calculate cooling capacity, please get the acreage data.
(3) Confirm the pipe system: 2 pipe or 4 pipe according to the cooling and heating source.
10. Our OEM and ODM service, Customer visit
EUROSTARS was established in 2006, has a professional technical team to research and develope HVAC products. We offer OEM/ODM service to our clients.
Now EUROSTARS collaborate with our clients in the following ways:
(1)Produce EUROSTARS standard products under clients' brand.
(2)Modify the products to satisfy clients' personalized requirements.
(3)If clients have their own idea and design of the products, EUROSTARS can actualize it and modify it make it easy for mass production.
11. Ultra thin fan coil installtion instruction
12. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
13. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..