Industrial Commercial Residential Four Way Cassette Type Fan Coil
1. Eurostars Fan coil unit series
1 |
Ceiling concealed fan coil unit |
2 |
High ESP ducted fan coil unit |
3 |
Universal concealed fan coil unit |
4 |
Floor standing exposed fan coil unit |
5 |
Ultra thin exposed fan coil unit |
6 |
Ceiling exposed fan coil unit |
7 |
Ceiling cassette fan coil unit |
8 |
Ceiling exposed & floor standing fan coil unit |
9 |
Wall mounted fan coil unit |
2.Ceiling cassette fan coil ingenious design
With high head lift drained water pump |
With inside float switch to prevent leaking |
Fresh air can be inputed from outside is optional |
4 pipe system and electrical heater is optional |
Installed water valve is optional |
Negative ion generator is optional |
Finger guard is optioanl to prevent beening injury |
Mod-Bus device is optional |
Power loss memory function is optional |
Unit external body insulation is optional |
EC or DC motor is optional |
3. Ceiling cassette fan coil types
Four style ceiling cassette fan coil unit can be selected:
Cassette type with 4 way air discharge, drained pump, remote controller |
Cassette type with 4 way air discharge, drained pump, wired controller |
Cassette type with 1 way air discharge, drained pump, remote controller |
Cassette type with 1 way air discharge, drained pump, wired controller |
4. Ceiling cassette fan coil unit main applications:
Showroom |
Shopping mall |
Restaurant & Bar |
Hotels |
Offices |
Building |
Clean room |
Library |
School |
Supermarket |
Exhibition hall |
Factory |
Apartments |
Dormitories |
5. Ceiling cassette fan coil unit main components
Fan |
Centrifugal type, pass statically and dynamically balanced test |
Motor |
Single-phase motors are suitable for different voltages, DC option |
Drain pump |
High lift water drained pump drains out the condensate water |
Coil |
Hydrophilic blue aluminium fin around with copper tube |
Casing |
Galvanized steel casing for master unit; ABS cover panel |
6. Ceiling cassette fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Cassette Fan Coil Unit (4-way 2 pipe system) |
Model EST~ |
200C2 |
300C2 |
400C2 |
500C2 |
600C2 |
800C2 |
1000C2 |
1200C2 |
1400C2 |
1600C2 |
Power supply |
220V-1PH-50/60HZ |
Air flow
(m3/h) |
H |
360 |
540 |
720 |
900 |
1080 |
1430 |
1780 |
2130 |
2480 |
1830 |
M |
290 |
390 |
525 |
670 |
775 |
1050 |
1290 |
1560 |
1810 |
2050 |
L |
190 |
270 |
350 |
440 |
540 |
720 |
870 |
1060 |
1290 |
1370 |
Static pressure |
Pa |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
Cooling capacity |
TH |
H |
W |
2000 |
3000 |
3800 |
4900 |
5800 |
7500 |
9800 |
11000 |
12000 |
15000 |
BTU/h |
6826 |
10239 |
12969 |
16724 |
19795 |
25598 |
33447 |
37543 |
40956 |
51195 |
SH |
W |
1400 |
2200 |
2850 |
3500 |
4250 |
5500 |
7150 |
8250 |
9100 |
11175 |
BTU/h |
4778 |
7509 |
9727 |
11946 |
14505 |
18772 |
24403 |
28157 |
31058 |
38140 |
TH |
M |
W |
1700 |
2550 |
3250 |
4150 |
4950 |
6400 |
8350 |
9350 |
10200 |
12450 |
BTU/h |
5802 |
8703 |
11092 |
14164 |
16894 |
21843 |
28499 |
31912 |
34813 |
42492 |
SH |
W |
1150 |
1800 |
2350 |
2850 |
3500 |
4550 |
5950 |
6850 |
7650 |
9560 |
BTU/h |
3925 |
6143 |
8021 |
9727 |
11946 |
15529 |
20307 |
23379 |
26109 |
32628 |
TH |
L |
W |
1400 |
2050 |
2600 |
3400 |
4000 |
5200 |
6750 |
7600 |
8300 |
10300 |
BTU/h |
4778 |
6997 |
8874 |
11604 |
13652 |
17748 |
23038 |
25939 |
28328 |
35154 |
SH |
W |
950 |
1400 |
1850 |
2300 |
2800 |
3600 |
4700 |
5450 |
6000 |
8400 |
BTU/h |
3242 |
4778 |
6314 |
7850 |
9556 |
12287 |
16041 |
18601 |
20478 |
28669 |
Heating capacity |
H |
W |
3100 |
4700 |
5900 |
7600 |
9000 |
11600 |
15200 |
17100 |
18600 |
24000 |
BTU/h |
10580 |
16041 |
20137 |
25939 |
30717 |
39591 |
51878 |
58362 |
63482 |
81912 |
M |
W |
2650 |
4000 |
5000 |
6450 |
7650 |
9850 |
12900 |
14550 |
15800 |
19900 |
BTU/h |
9044 |
13652 |
17065 |
22014 |
26109 |
12900 |
44028 |
49659 |
53925 |
67919 |
L |
W |
2100 |
3150 |
3950 |
5100 |
6050 |
7750 |
10200 |
11450 |
12450 |
15200 |
BTU/h |
7167 |
10751 |
13481 |
17406 |
20649 |
26451 |
34813 |
39079 |
42492 |
51878 |
Cassette Fan Coil Unit(4-way 4 pipe system) |
|
Model EST~ |
200C4 |
300C4 |
400C4 |
500C4 |
600C4 |
800C4 |
1000C4 |
1200C4 |
1400C4 |
1600C4 |
Power supply |
220V-1PH-50/60HZ |
Air flow
(m3/h) |
H |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
2720 |
M |
280 |
380 |
515 |
660 |
765 |
1040 |
1280 |
1550 |
1800 |
2040 |
L |
180 |
260 |
340 |
430 |
530 |
710 |
860 |
1050 |
1280 |
1360 |
Sta.pressure |
|
Pa |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
Cooling capacity |
TH |
H |
W |
1950 |
2950 |
3700 |
4800 |
5700 |
7350 |
9600 |
10800 |
11750 |
13200 |
BTU/h |
6655 |
10068 |
12628 |
16382 |
19454 |
25086 |
32765 |
36860 |
40103 |
45052 |
SH |
W |
1350 |
2150 |
2800 |
3450 |
4150 |
5400 |
7000 |
8100 |
8900 |
10000 |
BTU/h |
4608 |
7338 |
9556 |
11775 |
14164 |
18430 |
23891 |
27645 |
30376 |
34130 |
TH |
M |
W |
1650 |
2500 |
3200 |
4050 |
4850 |
6250 |
8200 |
9150 |
10000 |
11000 |
BTU/h |
5631 |
8533 |
10922 |
13823 |
16553 |
21331 |
27987 |
31229 |
34130 |
37543 |
SH |
W |
1150 |
1750 |
2300 |
2800 |
3450 |
4450 |
5850 |
6700 |
7500 |
37532 |
BTU/h |
3925 |
5973 |
7850 |
9556 |
11775 |
15188 |
19966 |
22867 |
25598 |
128097 |
TH |
L |
W |
1350 |
2000 |
2550 |
3350 |
3900 |
5100 |
6600 |
7450 |
8150 |
9100 |
BTU/h |
4608 |
6826 |
8703 |
11434 |
13311 |
17406 |
22526 |
25427 |
27816 |
31058 |
SH |
W |
950 |
1350 |
1800 |
2250 |
2750 |
3550 |
4600 |
5350 |
5900 |
6600 |
BTU/h |
3242 |
4608 |
6143 |
7679 |
9386 |
12116 |
15700 |
18260 |
20137 |
22526 |
Heating capacity |
H |
W |
1950 |
3000 |
3750 |
4850 |
5750 |
7400 |
9700 |
10900 |
11850 |
13500 |
BTU/h |
6655 |
10239 |
12799 |
16553 |
19625 |
25256 |
33106 |
37202 |
40444 |
46076 |
M |
W |
1700 |
2550 |
3200 |
4100 |
4850 |
6250 |
8200 |
9250 |
10050 |
11200 |
BTU/h |
5802 |
8703 |
10922 |
13993 |
16553 |
21331 |
27987 |
31570 |
34301 |
38226 |
L |
W |
1350 |
2000 |
2500 |
3250 |
3850 |
4950 |
6500 |
7300 |
7950 |
8750 |
BTU/h |
4608 |
6826 |
8533 |
11092 |
13140 |
16894 |
22185 |
24915 |
27133 |
29864 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
7.Ceiling cassette fan coil construction
8. Production line and Customer visit
9. Our warranty, technical support and failure claim proceduresand
(1) Warranty
a. Eurostars HVAC units delivered to customers are carefully examined and tested, with 48 hours trouble-free trial operation.
b. Eurostars HVAC units enjoy 1~1.5 years guarantee ever since B/L date.
(2)Technical support
a. Eurostars provide full technical support and training courses after equipment installation and commissioning.
b. 7*24 hours phone assistance on technical support.
c. Eurostars provide overseas guide installation,but not for free.
(3)Failure claim procedures
a. Detailed written failure description is required by fax or by mail, indicating the relevant equipment information and detailed description of failure.
b. Relevant pictures are required for failure confirmation.
c. Eurostars engineering and after-sales service team will check and form a diagnosis report.
d. Further trouble-shooting solutions will be offered to customers within 24 hours after receiving the written description and pictures.
10. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
11. Cassette fan coil installation instruction
12. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..