• Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation
  • Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation
  • Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation
  • Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation
  • Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation
  • Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation

Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation

Type: Fan Coil Unit
Air Tube Material: Galvanized Sheet Casing, Plastic Air Grille
Corrosion Durability: Higher
Operating Voltage: 110V/220~240V-50Hz/60Hz-1pH
Noise Level: Low
Application Fields: Restaurant/Hotel Room/Meeting Room/Office
Samples:
US$ 120/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
EST-HE VE series
Mounting
Ceiling Mount
Lifetime
15~20 years
Certification
CE
Condition
New
Main Usage
Chiller, Heat Pump, Underfloor Heating
Production Time
20 Days for Bulk Order
Installation
Ceiling Mounted /Floor Standing
Air Return
Front/Downward
Motor
AC or DC
Thermostat
Built-in Option
Pipe System
Two Pipe and Four Pipe System
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Trademark
ESACIR
Origin
Guangdong, Prc.
HS Code
8415830000
Production Capacity
10000 PCS/Year

Product Description

Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation

1. Ceiling exposed floor standing fan coil variable styles
Four style universal fan coil unit can be selected:
Horizontal ceiling type with air return from downward without supporting legs
Floor standing type with air return from front with supporting legs
Horizontal ceiling type with air return from backward without supporting legs
Floor standing type with air return from bottom with supporting legs

Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation

2. Ceiling exposed fan coil unit main characteristics
(1)Universal design, fan coil unit can be installed by both horizontally and vertically, use L style drain tray (whole plastic with hollow inside). Exposed fan coil can be installed with horizontal or vertical angle, or even any angle between 0~90 angle of degree.
(2) Four style fan coil unit can be selected: Floor standing type with air return from front/bottom with supporting legs/without supporting legs; Horizontal ceiling type with air return from backward/downward without supporting legs.
(3)Left-Right pipe connection can be changed before installation,the fan coil unit is supplied as standard with connections to the coil on the left. It is possible however to turn the coil round before installation,so that the connections are on the right.It is same to change from right connection to left connection.
(4)Air inlet direction can be changed, easy to change the air inlet direction from bottom inlet to side inlet.
(5)Different style controller can be pre-installed inside the fan coil unit, can selected 3-speed controller, LED thermostat, touch screen thermostat.
(6)Motor can be AC or DC with 0~10V stepless regulation thermostat.
(7)Convenient maintenace, casing can be easily taken out from the body by screws; fan motor module also can be easily taken out.

3. Ceiling exposed floor standing fan coil configuration
Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation


 
4. Eurostars Fan coil unit series
Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation
1 Ceiling concealed fan coil unit
2 High ESP ducted fan coil unit
3 Universal concealed fan coil unit
4 Floor standing exposed fan coil unit
5 Ultra thin exposed fan coil unit
6 Ceiling exposed fan coil unit
7 Ceiling cassette fan coil unit
8 Ceiling exposed & floor standing fan coil unit
9 Wall mounted fan coil unit

5. Ceiling floor standing exposed fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com

 
Universal Exposed Fan Coil Unit(2 pipe system)
Model   EST 200HE2 300HE2 400HE2 500HE2 600HE2 800HE2 1000HE2 1200HE2 1400HE2
200VE2 300VE2 400VE2 500VE2 600VE2 800VE2 1000VE2 1200VE2 1400VE2
Power supply 220V/1PH/50HZ
Air flow
 (m3/h)
H 340 510 680 850 1020 1360 1700 2040 2380
M 260 390 510 640 770 1020 1280 1530 1790
L 170 260 340 430 510 680 850 1020 1190
Cooling capacity TH H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
SH W 1368 2052 2736 3420 4103 5471 6839 8207 9575
TH M W 1494 2242 2989 3736 4483 5978 7472 8967 10461
SH W 1181 1771 2362 2952 3541 4722 5903 7084 8265
TH L W 1162 1744 2325 2906 3487 4649 5812 6974 8136
SH W 953 1430 1907 2383 2860 3813 4765 5718 6672
Heating capacity H W 2700 4050 5400 6750 8100 10800 13500 16200 18900
M W 2131 3197 4262 5328 6393 8524 10655 12786 14917
L W 1675 2511 3349 4186 5024 6697 8372 10046 11721
Universal Exposed Fan Coil Unit(4 pipe system)
Model   EST 200HE4 300HE4 400HE4 500HE4 600HE4 800HE4 1000HE4 1200HE4 1400HE4
200VE4 300VE4 400VE4 500VE4 600VE4 800VE4 1000VE4 1200VE4 1400VE4
Power supply 220V/1PH/50HZ
Air flow
 (m3/h)
H 340 510 680 850 1020 1360 1700 2040 2380
M 260 390 510 640 770 1020 1280 1530 1790
L 170 260 340 430 510 680 850 1020 1190
Cooling capacity TH H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
SH W 1368 2052 2736 3420 4103 5471 6839 8207 9575
TH M W 1494 2242 2989 3736 4483 5978 7472 8967 10461
SH W 1181 1771 2362 2952 3541 4722 5903 7084 8265
TH L W 1162 1744 2325 2906 3487 4649 5812 6974 8136
SH W 953 1430 1907 2383 2860 3813 4765 5718 6672
Heating capacity H W 1300 1940 2590 3240 3890 5180 6480 7780 9070
M W 1020 1530 2040 2550 3060 4070 5090 6110 7130
L W 820 1230 1630 2040 2450 3270 4080 4900 5720

Remarks:
(1)  Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)  Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature  60°C/50ºC.

 
6.Why choose EUROSTARS?  
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.

Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.

 
Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation
7. FAQ
Q: Can I have a samples for testing before ordering products?
A: Yes, you can.
We sincerely suggest that customers should have some samples of required fans for testing because the truly performance of fans can be fully demonstrated after testing is conducted.

Q: What is the warranty of products?
A: For 1~2 year warranty. Free to amend and change the parts due to quality reasons in warranty year.

Q: What kind of products do you have?
We have several series products with hundreds of models, including air / water chiller (with heat pumps), glycol chillers, AHU, FCU,  Rooftop,  cold room condensing unit, air conditioner for industrial and plant use and other equipment or parts for the ventilation system.

Q: How about your technological support?
1. We own a team of engineers majoring in design and test the air conditioning products with more than ten years' experience.
2. The company cooperates with some domestic and foreign well-known manufacturers, universities and design institutes. What's more, it has developed some products with core competence.
3. We could do personal design for clients as their production demand and their condition.

Q: How is your price?
We have our own factory. There is no middleman between clients and us. We give customers favorable price.

8. Our fan coil production line
Every fan coil has strict production process, including assembly, testing, packing.

Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation
Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation

9. Our service and Customer visit
Pre-Sales Service
(1) Inquiry and consulting support.
(2) Sample testing support.
(3) View our Factory.
After-Sales Service
(1)Provide customers with installation and commissioning online instructions. And we also provide local whole project installation.
(2) Well-trained engineers available to overseas service.
(3) Worldwide agents and after-sale service available.

Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation

 
10. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation
Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation

11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..

Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation
Heat Pump Chiller Hydrophilic Exposed Fan Coil Universal Installation

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now