Eurostars Screw Water Source Heat Pump Chiller/Ground Source Heat Pump

Product Details
Customization: Available
Energy Efficiency Grade: a Class
Heat Temperature: 50-70°C
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
Find Similar Products

Basic Info.

Model NO.
ESGW065SOHN
Heat Source
Water-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, CCC, SGS
Heat Pump Compresor
Taiwan Hanbell
Heat Pump Expansion Valve
Emerson
Heat Pump Dry Filter
Danfoss
Optional
Partial Heat Recovery
Compressor Quantity
1 or 2
Transport Package
Standard Export Package
Specification
CE
Trademark
Eurostars
Origin
Guangdong, Prc
HS Code
8418692090
Production Capacity
200 PCS/Year

Product Description

Eurostars Screw Water Source Heat Pump Chiller/Ground Source Heat Pump

1.Brief introduction-Eurostars water cooled chiller water source heat pump
a)Underground water source
b)Intellectualized control system and low noise
c)High efficient and energy saving
d)Easy operation and installation
e)Compact exterior
f)High quality
g)Competitive price
 
2.Unit Features-Eurostars water cooled water chiller water source heat pump
1).Heating capacity ranged from 105Kw to 3407 Kw.
2). Adopt good quality famous brand Hanbell screw compressor,high efficiency, low noise, less wearing and long life
3).Both Evaporator and Condenser are high quality and high efficiency
4). World famous brand parts: such Emerson expansion valve, FUJI contactor other brand like PUNP, Schneider.
5). Can be widely used in different area,such as Massage center, Hospital, Hotel, School, etc 
6). Strong unit base frame ensured the equipment stable operation 
7). Adopt leading brand PLC or SCM controller
8). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.
 
3.Technical parameter-water cooled water source heat pump
Please ask salesman for detailed complete data 
or visit our website: eurostarschiller.en.made-in-china.com
Screw-type Water Source Heat Pump (one compressor)
Model   ESGW 025SOHN 035SOHN 045SOHN 065SOHN 070SOHN 085SOHN 095SOHN 105SOHN 115SOHN 135SOHN
Rated Cooling
Capacity
Cooling Capacity (KW)  105 140 182 249 272 321 372 406 437 519
Cooling Capacity (USRT)  29.86  39.82  51.76  70.82  77.36  91.30  105.80  115.47  124.29  147.61 
Input Power (KW) 18.9 24.8 30.7 41.9 46.0 51.2 59.8 65.4 71.6 83.0
Rated Heating Capacity Heating Capacity (KW) 126 168 215 293 320 374 433 472 512 603
Heating Capacity (USRT) 35.84  47.78  61.15  83.33  91.01  106.37  123.15  134.24  145.62  171.50 
Input Power (KW) 26.7 35.0  43.1 58.9 64.6 71.5 83.5 91.3 100.1 115.9
Refrigerant R407C
Compressor Semi-hermetic  Screw Type  
Power Supply  3φ-380V-50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection,
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit 1
Capacity Control (%) 0,66,100 0,50,75,100
Refrigerant Charge (Kg) 17 24 30 40 44 52 59 65 71 86
Chilled Water Temp of inlet/outlet water 12ºC/7ºC
Water Side Max Pressure (MPa)
Dia.of Pipe  (inch)  2" 2-1/2" 3" 3" 3" 3" 4" 4" 4" 4"
Water Flow (m3/h) 18.1  24.1  31.3  42.8  46.8  55.2  64.0  69.8  75.2  89.3 
Pressure drop (kPa)  20 25 29 32 41 50 55 60 58 39
Underground
water
Temp of inlet/outlet water 18ºC/29ºC
Water Side Max Pressure (MPa) 1
Dia.of Pipe  (inch)  2" 2-1/2" 3" 3" 3" 3" 4" 4" 4" 5"
Water Flow (m3/h) 9.9 13.1 16.8 22.9 25 29.2 33.8 36.9 40 47.1
Pressure drop (kPa)  37 43 41 48 48 47 45 46 46 47
Running Noise dB(A) 73.1 73.7 74.8 75.0 75.0 79.6 80.4 81.5 83.1 84.2
Total weight (Kg) 880 910 1080 1220 1390 1510 1620 1720 1830 2140
Running Weight (Kg) 970 1010 1220 1380 1530 1670 1780 1870 2020 2400
Dimension L×W×H Detailed dimensions are according to the actual finished product sizes.

Screw-type Water Source Heat Pump (one compressor)
Model   ESGW 155SOHN 165SOHN 175SOHN 205SOHN 225SOHN 240SOHN 265SOHN 335SOHN 395SOHN 440SOHN
Rated Cooling
Capacity
Cooling Capacity (KW)  605 645 674 785 862 925 1033 1297 1527 1703
Cooling Capacity (USRT)  172.07  183.45  191.70  223.27  245.16  263.08  293.80  368.89  434.30  484.36 
Input Power (KW) 97.5 103.4 108.9 125.3 137.7 146.7 163.6 206.3 241.6 267.0
Rated Heating Capacity Heating Capacity (KW) 705 751 786 913 1002 1074 1198 1506 1771 1972
Heating Capacity (USRT) 200.51  213.59  223.55  259.67  284.98  305.46  340.73  428.33  503.70  560.86 
Input Power (KW) 136.1 144.3 152.1 175.1 192.3 204.9 228.6 288.2 337.5 372.9
Refrigerant R407C
Compressor Semi-hermetic  Screw Type  
Power Supply  3φ-380V-50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection,
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit 1
Capacity Control (%) 0,50,75,100
Refrigerant Charge (Kg) 97 105 109 127 141 150 168 207 243 277
Chilled Water Temp of inlet/outlet water 12ºC/7ºC
Water Side Max Pressure (MPa)
Dia.of Pipe  (inch)  5" 5" 5" 5" 5" 5" 5" 8" 8" 8"
Water Flow (m3/h) 104.1  110.9  115.9  135.0  148.3  159.1  177.7  223.1  262.6  292.9 
Pressure drop (kPa)  43 57 72 36 53 63 65 67 69 72
Underground
water
Temp of inlet/outlet water 18ºC/29ºC
Water Side Max Pressure (MPa) 1
Dia.of Pipe  (inch)  5" 5" 5" 5" 5" 5" 6" 6" 8" 8"
Water Flow (m3/h) 55.1 58.7 61.4 71.4 78.3 84 93.7 117.7 138.5 154.1
Pressure drop (kPa)  46 47 53 59 61 62 65 67 76 81
Running Noise dB(A) 86.3 86.6 86.9 87.1 87.3 87.6 88.4 90.3 90.8 91.2
Total weight (Kg) 2270 2460 2540 2680 2900 3060 3310 3740 3980 4300
Running Weight (Kg) 2520 2720 2920 3060 3380 3600 3830 4260 4520 4840
Dimension L×W×H  Detailed dimensions are according to the actual finished product sizes.

(1).Rated Cooling Capacity Based on: Underground water in/outlet temp 18ºC/29ºC;Chilled water in/outlet temp. 12ºC/7ºC,  Fouling factor: 0.088.°C/KW.
(2).Rated heating capacity based on:Underground water inlet temp. 15°C;Hhot water inlet temp. 40°C.

4.Eurostars water cooled water source heat pump water chiller protection devices
1)Phase reversion protection, 
2)Overload current protection,
4)Phase lack protection, 
5)Discharge air temp. protection, 
6)Low&High pressure protection, 
7)Reserved water flow protection interface,
8)Low temp. protection.

5.Eurostars water source heat pump chiller series
-Commercial Water Source Heat Pump Chiller
-Scroll type water cooled water source heat pump
-Screw type water cooled water source heat pump
-Flooded type water cooled water source heat pump
 
-Commercial Air Cooled Heat Pump Chiller
-Scroll type air cooled air source heat pump
-Screw type air cooled air source heat pump
 
-Cooling&Heating&Sanitay hot water
-Air source heat pump with heat recovery
-Water source heat pump with heat recovery

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier