Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit

Product Details
Customization: Available
Type: Fan Coil Unit
Air Tube Material: Galvanized Sheet
Still deciding? Get samples of US$ 230/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
  • Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit
  • Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit
  • Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit
  • Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit
  • Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit
  • Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit
Find Similar Products

Basic Info.

Model NO.
EST series
Corrosion Durability
Higher
Operating Voltage
110V/220~240V-50Hz/60Hz-1pH
Noise Level
Low
Application Fields
Restaurant/Hotel Room
Mounting
Ceiling Concealed
Lifetime
>20 years
Certification
CE
Condition
New
Pipe System
Two Pipe and Four Pipe System
Production Time
20 Days for Bulk Order
Air Outlet Static Pressure
0, 12, 30, 50PA
Air Return
Backward/Downward
Rows
3 Rows
Main Usage
Chiller, Heat Pump, Underfloor Heating
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Trademark
ESACIR
Origin
Guangdong, Prc.
HS Code
8415830000
Production Capacity
10000 PCS/Year

Product Description

Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit

1. Ceiling concealed fan coil brief description 
Backed by a team of skilled professionals, our enterprise is able to offer a wide range of fan coil unit that produces very less noise. Offered range is manufactured using finest quality raw material and advance technology under the strict industry laid norms. Our offered fan coil unit is available in different specifications and sizes as per the requirements of the clients.

Eurostars ceiling concealed fan coils can be installed in hotels, apartments, multi-room buildings, commercial office, school, hospital, shopping mall, villa, sauna room, subway station, etc.

2. Ceiling concealed fan coil unit main components
Horizontal concealed fan coil units are mainly consist of fan, motor, drain pan, water coil, casing, optional return air plenum and filter.
Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit

3. Ceiling concealed fan coil unit features
(1) Compact structure design with thickness of 238mm only to save space;
(2) Low noise with stable running;
(3) The motor can be dismantled from the return outlet for maintains at the season changing period;
(4) Fresh air intake can be pre-made in return air box;
(5) Condensed water tray can be extended, if required, to ensure collecting the water and it can be made of stainless steel or galvanization steel plate;
(6) Four-pipe type is available for consideration.

4. Ceiling horizontal concealed fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Horizontal Concealed Fan Coil Unit (2 pipe system)
Model EST~ 200HC2 300HC2 400HC2 500HC2 600HC2 800HC2 1000HC2 1200HC2 1400HC2
Air flow (m3/h)
(0/12Pa,30Pa Static Pressure)
High  340 510 680 850 1020 1360 1700 2040 2380
Medium  270 380 515 660 765 1040 1280 1550 1800
Low  190 260 340 430 530 710 860 1050 1280
Rated cooling capacity  H TH(W) 1800 2700 3600 4500 5400 7200 9000 10800 12600
SH(W) 1341 2012 2682 3353 4023 5364 6705 8046 9387
M TH(W) 1485 2187 2916 3645 4374 5832 7290 8748 10206
SH(W) 1152 1728 2304 2880 3455 4607 5759 6911 8063
L TH(W) 1134 1701 2268 2835 3402 4536 5670 6804 7938
SH(W) 930 1395 1860 2325 2790 3720 4649 5579 6509
Rated heating capacity  H W 2700 4050 5400 6750 8100 10800 13500 16200 18900
M 2079 3119 4158 5198 6237 8316 10395 12474 14553
L 1634 2450 3267 4084 4901 6534 8168 9801 11435
Horizontal Concealed Fan Coil Unit (4 pipe system)
Model EST~ 200HC4 300HC4 400HC4 500HC4 600HC4 800HC4 1000HC4 1200HC4 1400HC4
Air flow (m3/h)
(0/12Pa,30Pa Static Pressure)
High  340 510 680 850 1020 1360 1700 2040 2380
Medium  270 380 515 660 765 1040 1280 1550 1800
Low  190 260 340 430 530 710 860 1050 1280
Rated cooling capacity  H TH(W) 1800 2700 3600 4500 5400 7200 9000 10800 12600
SH(W) 1341 2012 2682 3353 4023 5364 6705 8046 9387
M TH(W) 1485 2187 2916 3645 4374 5832 7290 8748 10206
SH(W) 1152 1728 2304 2880 3455 4607 5759 6911 8063
L TH(W) 1134 1701 2268 2835 3402 4536 5670 6804 7938
SH(W) 930 1395 1860 2325 2790 3720 4649 5579 6509
Rated heating capacity  H W 1080 1620 2160 2700 3240 4320 5400 6480 7560
M 832 1248 1663 2079 2495 3326 4158 4990 5821
L 654 980 1307 1634 1960 2614 3267 3920 4574
Remarks:
(1)  Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)  Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature  60°C/50ºC.

 
5. Fan coil unit series
Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit

Ceiling concealed fan coil unit
High ESP ducted fan coil unit
Universal concealed fan coil unit
Floor standing exposed fan coil unit
Ultra thin exposed fan coil unit
Ceiling exposed fan coil unit
Ceiling cassette fan coil unit
Ceiling exposed & floor standing fan coil unit
Wall mounted fan coil unit
 
6.About us:
(1) With more certificate
(2) Professional team with over more than 10 years industry knowledge
(3) Oversea installation.
(4) Customer-made accepted.
(5) Diamond member of Made-In-China
(6) Audited supplier by SGS
Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit

Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit

7. How to choose the fan coil?
(1) Firstly need to know the application site, for example, hotel room generally choose ceiling concealed fan coil, restaurant generally choose ceiling cassette fan coil, it depends on site requirements.
(2) If need to calculate cooling capacity, please get the acreage data.
(3) Confirm the pipe system: 2 pipe or 4 pipe according to the cooling and heating source.

8.FAQ
Q: Can I have a sample for testing before ordering products?
A: Yes, you can. And you are warmly welcomed to visit our factory before PO.

Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.

Q: How to properly install the fan coil unit?
A: We have very detailed user manual and installation instructions, also can be directly telephone  or online video guidance.

 
9. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit

10. Ceiling concealed fan coil installation instruction
(1) Air duct must be fireproof regulations for buildings.
(2) For horizontal air supply, N≥150 MM; if air duct is longer than 1 m, N≥200 mm.
(3) Size of M depends on air duct installation. Pressure loss of circulatory air must be consistent with outlet static pressure of the unit.
Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit

11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..
Ceiling Concealed Fan Coil Chilled Water Fan Coil Unit

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier