Horizontal Concealed Chilled Water Fan Coil Unit Ventilation Fan Coil Unit
1. ESAICR Fan coil unit series
Ceiling concealed fan coil unit
High ESP ducted fan coil unit
Universal concealed fan coil unit
Floor standing exposed fan coil unit
Ultra thin exposed fan coil unit
Ceiling exposed fan coil unit
Ceiling cassette fan coil unit
Ceiling exposed & floor standing fan coil unit
Wall mounted fan coil unit
2. Ceiling concealed fan coil product application
Fan coil unit is the terminal of central air conditioning system. It consists of centrifugal fan and copper tube heat exchanger.The ceiling consealed fan coil unit can be embedded in the ceiling and merged with interior decoration. Only exposing tuyere, which save space and easy maintenance. Widely used in hotels, restaurants, factories, hospitals, exhibition hall, shopping malls, office rooms and other industrial and civil construction of the combined air-conditioning system to meet the cooling, heating and other requirements.
3. Ceiling concealed fan coil unit main components
(1) Fan
Fans are double inlets multi-blade centrifugal type. All fans are statically and dynamically balanced.
(2) Motor
Single-phase motors are suitable for different voltages, such as 110V, 115V, 120V, 220V, 230V, 240V. All motors have 10 percent voltage utilization range and wired to unit terminal box. Motors are designed for long life.
(3) Drain pan
Dray pan is integrally attached to coil casings and ended with drain hose. All pans are galvanized for corrosion resistance and cover the entire coil.
(4) Water coil
Coils are 3-row as standard design together with 4-row design as option. High efficient hydrophilic aluminum fins are mechanically bonded to seamless copper tubes. All coils are specifically designed and circuited for water use. All coils are tested at 3.3MPa.
(5) Casing
Casing are constructed of heavy gauge steel. Interior surface of unit panels are acoustically and thermally insulated with polyethylene foam.
Units are furnished as standard with a 1 inch duct collar to facilitate connection of the supply air duct.
(6) Return air plenum (optional)
The fan coil unit shall be factory installed return air plenum that encloses the fan section of the unit. No field fabrication is required. The return air arrangement is adaptable between bottom or rear return of the plenum.
(7) Washable filter (optional)
Filter should be accessible from return air grille
4. Ceiling horizontal concealed fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Horizontal Concealed Fan Coil Unit (2 pipe system) |
Model EST~ |
200HC2 |
300HC2 |
400HC2 |
500HC2 |
600HC2 |
800HC2 |
1000HC2 |
1200HC2 |
1400HC2 |
Air flow (m3/h)
(0/12Pa,30Pa Static Pressure) |
High |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
Medium |
270 |
380 |
515 |
660 |
765 |
1040 |
1280 |
1550 |
1800 |
Low |
190 |
260 |
340 |
430 |
530 |
710 |
860 |
1050 |
1280 |
Rated cooling capacity |
H |
TH(W) |
1800 |
2700 |
3600 |
4500 |
5400 |
7200 |
9000 |
10800 |
12600 |
SH(W) |
1341 |
2012 |
2682 |
3353 |
4023 |
5364 |
6705 |
8046 |
9387 |
M |
TH(W) |
1485 |
2187 |
2916 |
3645 |
4374 |
5832 |
7290 |
8748 |
10206 |
SH(W) |
1152 |
1728 |
2304 |
2880 |
3455 |
4607 |
5759 |
6911 |
8063 |
L |
TH(W) |
1134 |
1701 |
2268 |
2835 |
3402 |
4536 |
5670 |
6804 |
7938 |
SH(W) |
930 |
1395 |
1860 |
2325 |
2790 |
3720 |
4649 |
5579 |
6509 |
Rated heating capacity |
H |
W |
2700 |
4050 |
5400 |
6750 |
8100 |
10800 |
13500 |
16200 |
18900 |
M |
2079 |
3119 |
4158 |
5198 |
6237 |
8316 |
10395 |
12474 |
14553 |
L |
1634 |
2450 |
3267 |
4084 |
4901 |
6534 |
8168 |
9801 |
11435 |
Horizontal Concealed Fan Coil Unit (4 pipe system) |
Model EST~ |
200HC4 |
300HC4 |
400HC4 |
500HC4 |
600HC4 |
800HC4 |
1000HC4 |
1200HC4 |
1400HC4 |
Air flow (m3/h)
(0/12Pa,30Pa Static Pressure) |
High |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
Medium |
270 |
380 |
515 |
660 |
765 |
1040 |
1280 |
1550 |
1800 |
Low |
190 |
260 |
340 |
430 |
530 |
710 |
860 |
1050 |
1280 |
Rated cooling capacity |
H |
TH(W) |
1800 |
2700 |
3600 |
4500 |
5400 |
7200 |
9000 |
10800 |
12600 |
SH(W) |
1341 |
2012 |
2682 |
3353 |
4023 |
5364 |
6705 |
8046 |
9387 |
M |
TH(W) |
1485 |
2187 |
2916 |
3645 |
4374 |
5832 |
7290 |
8748 |
10206 |
SH(W) |
1152 |
1728 |
2304 |
2880 |
3455 |
4607 |
5759 |
6911 |
8063 |
L |
TH(W) |
1134 |
1701 |
2268 |
2835 |
3402 |
4536 |
5670 |
6804 |
7938 |
SH(W) |
930 |
1395 |
1860 |
2325 |
2790 |
3720 |
4649 |
5579 |
6509 |
Rated heating capacity |
H |
W |
1080 |
1620 |
2160 |
2700 |
3240 |
4320 |
5400 |
6480 |
7560 |
M |
832 |
1248 |
1663 |
2079 |
2495 |
3326 |
4158 |
4990 |
5821 |
L |
654 |
980 |
1307 |
1634 |
1960 |
2614 |
3267 |
3920 |
4574 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
5. Ceiling concealed fan coil unit features
(1) Excellent performance
(2) High reliability
(3) Easy maintenance
(4) Simple installation
6. FAQ
Q: How to choose the fan coil?
A:
(1) Firstly need to know the application site, for example, hotel room generally choose ceiling concealed fan coil, restaurant generally choose ceiling cassette fan coil, it depends on site requirements.
(2) If need to calculate cooling capacity, please get the acreage data.
(3) Confirm the pipe system: 2 pipe or 4 pipe according to the cooling and heating source.
Q: How to get a prompt quotation?
A: When you send the inquiry to us, please kindly provide the below technical information:
(a) Fan coil unit type: concealed, or exposed, ceiling installation or floor standing installation
(b) Cooling capacity: Kcal/hr or KW, TR, TONS, BTU/H
(c) Plenum box: Backward or downward, filter need or not
(d) Voltages and Frequency : V/PH/HZ
(e) Application:
Q: How about your service?
A: Our service
Before-sale services:
(1)Tell clients how to use our products and matters needing attention.
(2)Guide clients to choose the best and economic product, recover the investment within short time.
(3)Site inspection if client require.
In-sale services:
(1)Quality control must be inspect strictly.
(2)In accordance with the agrements stipulated in the contract.
After-sale services
(1)If the project needs our installation guidance, we can send our engineer and translator. We can also send customers installation video to teach them how to fix and operate with our product.
(2)Usually, our product warranty is 12 months since BL date, within this warranty period, all parts broken will be responsible for our factory.
7. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
8. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..