Hot Water Fan Coil Heating Cassette Type Fan Coil Unit
1.Ceiling cassette fan coil brief introduction
Product Type |
Ceiling Cassette Fan Coil Unit |
Motor |
AC (DC as optional) |
Air Outlet |
4 way air discharge (1 way,,360 angle degrees optional ) |
Pipe System |
2 pipes or 4 pipes |
Cooling Capacity |
2KW ~ 15KW (2 pipe system) |
Heating Capacity |
3.1KW ~ 24KW (2 pipe system) |
Cooling Capacity |
1.95KW ~ 13.2KW (4 pipe system) |
Heating Capacity |
1.95KW ~ 13.5W (4 pipe system) |
Main applications:
Showroom |
Shopping mall |
Restaurant & Bar |
Hotels |
Offices |
Building |
Clean room |
Library |
School |
Supermarket |
Exhibition hall |
Factory |
Apartments |
Dormitories |
2. Eurostars Fan coil unit series
1 |
Ceiling concealed fan coil unit |
2 |
High ESP ducted fan coil unit |
3 |
Universal concealed fan coil unit |
4 |
Floor standing exposed fan coil unit |
5 |
Ultra thin exposed fan coil unit |
6 |
Ceiling exposed fan coil unit |
7 |
Ceiling cassette fan coil unit |
8 |
Ceiling exposed & floor standing fan coil unit |
9 |
Wall mounted fan coil unit |
3. Ceiling cassette fan coil unit main components
Fan |
Centrifugal type, pass statically and dynamically balanced test |
Motor |
Single-phase motors are suitable for different voltages, DC option |
Drain pump |
High lift water drained pump drains out the condensate water |
Coil |
Hydrophilic blue aluminium fin around with copper tube |
Casing |
Galvanized steel casing for master unit; ABS cover panel |
4. Ceiling cassette fan coil features
(1) 4-way air flowing, which can uniform temperature distribution in the room, automatic swing wind;
(2) 2 tube or 4 tube are optional, flexible control mode, both remote control and wired control(optional);
(3) With inner drain pump, high lift condensate pump design, condensation water pipe layout is more flexible and convenient;
(4) Thin design unit which can be installed in a limit ceiling, unit body thinnest only 290mm;
(5) The design of this product cater for easy installing in order to decease the installation cost;
(6) Using large diameter vortex centrifugal fan, ultra quiet operation;
(7) Water level switch protection, put an end to leakage hidden danger;
(8) Outdoor fresh air can be introduced to improve indoor air quality;
(9) The auxiliary air outlet can be arranged to send some air to the other parts, there by improving the indoor temperature and the uniformity of the airflow field;
(10) Optional anion generator, fresh indoor air;
(11) Can manually remove the remaining water in the water tray;
(12) "U" type heat exchanger, hydrophilic aluminum foil fin.
5. Ceiling cassette fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Cassette Fan Coil Unit (4-way 2 pipe system) |
Model EST~ |
200C2 |
300C2 |
400C2 |
500C2 |
600C2 |
800C2 |
1000C2 |
1200C2 |
1400C2 |
1600C2 |
Power supply |
220V-1PH-50/60HZ |
Air flow
(m3/h) |
H |
360 |
540 |
720 |
900 |
1080 |
1430 |
1780 |
2130 |
2480 |
1830 |
M |
290 |
390 |
525 |
670 |
775 |
1050 |
1290 |
1560 |
1810 |
2050 |
L |
190 |
270 |
350 |
440 |
540 |
720 |
870 |
1060 |
1290 |
1370 |
Static pressure |
Pa |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
Cooling capacity |
TH |
H |
W |
2000 |
3000 |
3800 |
4900 |
5800 |
7500 |
9800 |
11000 |
12000 |
15000 |
BTU/h |
6826 |
10239 |
12969 |
16724 |
19795 |
25598 |
33447 |
37543 |
40956 |
51195 |
SH |
W |
1400 |
2200 |
2850 |
3500 |
4250 |
5500 |
7150 |
8250 |
9100 |
11175 |
BTU/h |
4778 |
7509 |
9727 |
11946 |
14505 |
18772 |
24403 |
28157 |
31058 |
38140 |
TH |
M |
W |
1700 |
2550 |
3250 |
4150 |
4950 |
6400 |
8350 |
9350 |
10200 |
12450 |
BTU/h |
5802 |
8703 |
11092 |
14164 |
16894 |
21843 |
28499 |
31912 |
34813 |
42492 |
SH |
W |
1150 |
1800 |
2350 |
2850 |
3500 |
4550 |
5950 |
6850 |
7650 |
9560 |
BTU/h |
3925 |
6143 |
8021 |
9727 |
11946 |
15529 |
20307 |
23379 |
26109 |
32628 |
TH |
L |
W |
1400 |
2050 |
2600 |
3400 |
4000 |
5200 |
6750 |
7600 |
8300 |
10300 |
BTU/h |
4778 |
6997 |
8874 |
11604 |
13652 |
17748 |
23038 |
25939 |
28328 |
35154 |
SH |
W |
950 |
1400 |
1850 |
2300 |
2800 |
3600 |
4700 |
5450 |
6000 |
8400 |
BTU/h |
3242 |
4778 |
6314 |
7850 |
9556 |
12287 |
16041 |
18601 |
20478 |
28669 |
Heating capacity |
H |
W |
3100 |
4700 |
5900 |
7600 |
9000 |
11600 |
15200 |
17100 |
18600 |
24000 |
BTU/h |
10580 |
16041 |
20137 |
25939 |
30717 |
39591 |
51878 |
58362 |
63482 |
81912 |
M |
W |
2650 |
4000 |
5000 |
6450 |
7650 |
9850 |
12900 |
14550 |
15800 |
19900 |
BTU/h |
9044 |
13652 |
17065 |
22014 |
26109 |
12900 |
44028 |
49659 |
53925 |
67919 |
L |
W |
2100 |
3150 |
3950 |
5100 |
6050 |
7750 |
10200 |
11450 |
12450 |
15200 |
BTU/h |
7167 |
10751 |
13481 |
17406 |
20649 |
26451 |
34813 |
39079 |
42492 |
51878 |
Cassette Fan Coil Unit(4-way 4 pipe system) |
|
Model EST~ |
200C4 |
300C4 |
400C4 |
500C4 |
600C4 |
800C4 |
1000C4 |
1200C4 |
1400C4 |
1600C4 |
Power supply |
220V-1PH-50/60HZ |
Air flow
(m3/h) |
H |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
2720 |
M |
280 |
380 |
515 |
660 |
765 |
1040 |
1280 |
1550 |
1800 |
2040 |
L |
180 |
260 |
340 |
430 |
530 |
710 |
860 |
1050 |
1280 |
1360 |
Sta.pressure |
|
Pa |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
Cooling capacity |
TH |
H |
W |
1950 |
2950 |
3700 |
4800 |
5700 |
7350 |
9600 |
10800 |
11750 |
13200 |
BTU/h |
6655 |
10068 |
12628 |
16382 |
19454 |
25086 |
32765 |
36860 |
40103 |
45052 |
SH |
W |
1350 |
2150 |
2800 |
3450 |
4150 |
5400 |
7000 |
8100 |
8900 |
10000 |
BTU/h |
4608 |
7338 |
9556 |
11775 |
14164 |
18430 |
23891 |
27645 |
30376 |
34130 |
TH |
M |
W |
1650 |
2500 |
3200 |
4050 |
4850 |
6250 |
8200 |
9150 |
10000 |
11000 |
BTU/h |
5631 |
8533 |
10922 |
13823 |
16553 |
21331 |
27987 |
31229 |
34130 |
37543 |
SH |
W |
1150 |
1750 |
2300 |
2800 |
3450 |
4450 |
5850 |
6700 |
7500 |
37532 |
BTU/h |
3925 |
5973 |
7850 |
9556 |
11775 |
15188 |
19966 |
22867 |
25598 |
128097 |
TH |
L |
W |
1350 |
2000 |
2550 |
3350 |
3900 |
5100 |
6600 |
7450 |
8150 |
9100 |
BTU/h |
4608 |
6826 |
8703 |
11434 |
13311 |
17406 |
22526 |
25427 |
27816 |
31058 |
SH |
W |
950 |
1350 |
1800 |
2250 |
2750 |
3550 |
4600 |
5350 |
5900 |
6600 |
BTU/h |
3242 |
4608 |
6143 |
7679 |
9386 |
12116 |
15700 |
18260 |
20137 |
22526 |
Heating capacity |
H |
W |
1950 |
3000 |
3750 |
4850 |
5750 |
7400 |
9700 |
10900 |
11850 |
13500 |
BTU/h |
6655 |
10239 |
12799 |
16553 |
19625 |
25256 |
33106 |
37202 |
40444 |
46076 |
M |
W |
1700 |
2550 |
3200 |
4100 |
4850 |
6250 |
8200 |
9250 |
10050 |
11200 |
BTU/h |
5802 |
8703 |
10922 |
13993 |
16553 |
21331 |
27987 |
31570 |
34301 |
38226 |
L |
W |
1350 |
2000 |
2500 |
3250 |
3850 |
4950 |
6500 |
7300 |
7950 |
8750 |
BTU/h |
4608 |
6826 |
8533 |
11092 |
13140 |
16894 |
22185 |
24915 |
27133 |
29864 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
6. Ceiling cassette fan coil construction and pipe system
7. About EUROSTARS
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Webiste 1: http://eurostarschiller.en.made-in-china.com/
Website 2: http://eurostarschiller.en.made-in-china.com/
Instagram: https://eurostarschiller.en.made-in-china.com
Facebook: https://eurostarschiller.en.made-in-china.com
Youtube https://eurostarschiller.en.made-in-china.com
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
8. FAQ
Q: Can I have a sample for testing before ordering products?
A: Yes, you can. And you are warmly welcomed to visit our factory before PO.
Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
Q: How to properly install the fan coil unit?
A: We have very detailed user manual and installation instructions, also can be directly telephone or online video guidance.
Q: How about your after-sale service?
(a)Provide customers with installation and commissioning online instructions. And we also provide local whole project installation.
(b) Well-trained engineers available to overseas service.
(c) Worldwide agents and after-sale service available.
Q: Do you test all your goods before delivery?
A: Yes, we have 100% test before delivery.
Q: How to deal with the faulty?
A: Our products are produced in strict quality control system, but if any faulty, we'll send new spare parts for free in one warranty year.
9. Our warranty, technical support and failure claim proceduresand
(1) Warranty
a. Eurostars HVAC units delivered to customers are carefully examined and tested, with 48 hours trouble-free trial operation.
b. Eurostars HVAC units enjoy 1~1.5 years guarantee ever since B/L date.
(2)Technical support
a. Eurostars provide full technical support and training courses after equipment installation and commissioning.
b. 7*24 hours phone assistance on technical support.
c. Eurostars provide overseas guide installation,but not for free.
(3)Failure claim procedures
a. Detailed written failure description is required by fax or by mail, indicating the relevant equipment information and detailed description of failure.
b. Relevant pictures are required for failure confirmation.
c. Eurostars engineering and after-sales service team will check and form a diagnosis report.
d. Further trouble-shooting solutions will be offered to customers within 24 hours after receiving the written description and pictures.
10 . Customers visit
Warmly welcome customers visit us.
11. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
12. Cassette fan coil installation instruction
13. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..