Floor Standing Fan Coil Installation for Central Air Conditioning System
1. Ceiling mounted floor standing fan coil brief introduction
Fan coil units are referred to as fan coils. It is one of the end devices of an air conditioning system consisting of a small fan, a motor and a coil (air heat exchanger). When the chilled water or hot water flows through the coil pipe, heat is exchanged with the air outside the pipe, the air is cooled, and the indoor air parameters are adjusted by dehumidifying or heating. It is a commonly used cooling and heating terminal device.
(1)Showroom
(2) Shopping mall
(3) Restaurant & Bar
(4) Hotels
(5) Offices
(6) Building
(7) Clean room
(8) Other fields
2. Ceiling mounted floor standing fan coil unit main components
Fan |
Centrifugal type, pass statically and dynamically balanced test |
Motor |
Single-phase motors are suitable for different voltages |
Water tray |
Help to drain out the condensate water |
Coil |
Hydrophilic blue aluminium fin around with copper tube |
Casing |
Galvanized steel casing; ABS air grille |
3. Ceiling mounted exposed floor standing fan coil features
(1)Air flow: The fan coil unit can supply air vertically in a 70-degree range and horizontally in a 100-degree range. It can generate a strong air current at a height of 4 meters to meet requirements of various usage scenarios.
(2)Low noise: The fan coil unit features a forward-pitched low-speed centrifugal fan with wide impellers. The fan has a good dynamic balance and a stable performance, and minimizes the operation sound while ensuring enough air flow and the static pressure of outlet air by using efficient sound-dampening and heat-insulation material.
(3)Efficient and energy saving: To maximize heat transfer and exchange efficiency, the fan coil unit features heat exchange coils made of quality copper tubes, efficient hyperbolic aluminum shutter fins, precise mechanic tube expansion.
(4)Flexible installation: The fan coil unit can be easily installed it in the ceiling or on the floor to match with decoration styles.
(5)Easy operation: With thin body can be installed in a limit ceiling, easy to be installed, no need air duct,save installation cost; Humanized remote controller and wire controller(optional).
4. Eurostars Fan coil unit series
1 |
Ceiling concealed fan coil unit |
2 |
High ESP ducted fan coil unit |
3 |
Universal concealed fan coil unit |
4 |
Floor standing exposed fan coil unit |
5 |
Ultra thin exposed fan coil unit |
6 |
Ceiling exposed fan coil unit |
7 |
Ceiling cassette fan coil unit |
8 |
Ceiling exposed & floor standing fan coil unit |
9 |
Wall mounted fan coil unit |
5. Ceiling mounted floor standing exposed fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Ceiling Exposed/Floor Mounted Fan Coil Unit (2 pipe system) |
Model EST~ |
300CF2 |
400CF2 |
500CF2 |
600CF2 |
800CF2 |
1000CF2 |
1200CF2 |
1400CF2 |
Air flow
(m3/h) |
High |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
Medium |
420 |
560 |
770 |
910 |
1210 |
1450 |
1850 |
2150 |
Low |
340 |
480 |
610 |
820 |
1100 |
1380 |
1600 |
2000 |
Cooling capacity |
TH |
H |
W |
2700 |
3600 |
4500 |
5400 |
7200 |
9000 |
10800 |
12600 |
BTU |
9215 |
12287 |
15359 |
18430 |
24574 |
30717 |
36860 |
43004 |
SH |
W |
1990 |
2730 |
3174 |
4261 |
5385 |
6746 |
8109 |
9062 |
BTU |
6792 |
9317 |
10833 |
14543 |
18379 |
23024 |
27676 |
30929 |
TH |
M |
W |
2485 |
3030 |
3752 |
4467 |
6499 |
7926 |
9389 |
10605 |
BTU |
8481 |
10341 |
12806 |
15246 |
22181 |
27051 |
32045 |
36195 |
SH |
W |
1570 |
2015 |
2450 |
3070 |
4278 |
5447 |
6669 |
7262 |
BTU |
5358 |
6877 |
8362 |
10478 |
14601 |
18591 |
22761 |
24785 |
TH |
L |
W |
2078 |
2504 |
2950 |
3831 |
5660 |
7295 |
8619 |
8989 |
BTU |
7092 |
8546 |
10068 |
13075 |
19318 |
24898 |
29417 |
30679 |
SH |
W |
1212 |
1545 |
1844 |
2397 |
3317 |
4460 |
5300 |
5555 |
BTU |
4137 |
5273 |
6294 |
8181 |
11321 |
15222 |
18089 |
18959 |
Heating capacity |
H |
W |
4050 |
5400 |
6750 |
8100 |
10800 |
13500 |
16200 |
18900 |
BTU/h |
13823 |
18430 |
23038 |
27645 |
36860 |
46076 |
55291 |
64506 |
M |
W |
2792 |
3970 |
4941 |
5740 |
7987 |
10557 |
13101 |
14011 |
BTU/h |
9529 |
13550 |
16864 |
19591 |
27260 |
36031 |
44714 |
47820 |
L |
W |
1788 |
2800 |
3533 |
3907 |
5464 |
7048 |
8714 |
9778 |
BTU/h |
6102 |
9556 |
12058 |
13335 |
18649 |
24055 |
29741 |
33372 |
Ceiling Exposed/Floor Mounted Fan Coil Unit (4 pipe system) |
Model EST~ |
300CF4 |
400CF4 |
500CF4 |
600CF4 |
800CF4 |
1000CF4 |
1200CF4 |
1400CF4 |
Air flow
(m3/h) |
High |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
Medium |
420 |
560 |
770 |
910 |
1210 |
1450 |
1850 |
2150 |
Low |
340 |
480 |
610 |
820 |
1100 |
1380 |
1600 |
2000 |
Cooling capacity |
TH |
H |
W |
2025 |
2700 |
3375 |
4050 |
5400 |
6750 |
8100 |
9450 |
BTU |
6911 |
9215 |
11519 |
13823 |
18430 |
23038 |
27645 |
32253 |
SH |
W |
1532 |
2102 |
2445 |
3281 |
4146 |
5194 |
6245 |
6978 |
BTU |
5229 |
7174 |
8345 |
11198 |
14150 |
17727 |
21314 |
23816 |
TH |
M |
W |
1864 |
2273 |
2814 |
3350 |
4874 |
5945 |
7042 |
7954 |
BTU |
6362 |
7758 |
9604 |
11434 |
16635 |
20290 |
24034 |
27147 |
SH |
W |
1210 |
1552 |
1887 |
2365 |
3295 |
4195 |
5135 |
5592 |
BTU |
4130 |
5297 |
6440 |
8072 |
11246 |
14318 |
17526 |
19085 |
TH |
L |
W |
1559 |
1878 |
2213 |
2873 |
4245 |
5470 |
6465 |
6742 |
BTU |
5321 |
6410 |
7553 |
9806 |
14488 |
18669 |
22065 |
23010 |
SH |
W |
933 |
1190 |
1420 |
1845 |
2555 |
3435 |
4081 |
4277 |
BTU |
3184 |
4061 |
4846 |
6297 |
8720 |
11724 |
13928 |
14597 |
Heating capacity |
H |
W |
1620 |
2160 |
2701 |
3240 |
4320 |
5400 |
6480 |
7560 |
BTU/h |
5529 |
7372 |
9219 |
11058 |
14744 |
18430 |
22116 |
25802 |
M |
W |
1115 |
1588 |
1976 |
2296 |
3195 |
4223 |
5240 |
5604 |
BTU/h |
3805 |
5420 |
6744 |
7836 |
10905 |
14413 |
17884 |
19126 |
L |
W |
715 |
1120 |
1413 |
1563 |
2186 |
2819 |
3486 |
3911 |
BTU/h |
2440 |
3823 |
4823 |
5335 |
7461 |
9621 |
11898 |
13348 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
6. Ceiling floor fan coil unit construction parts
7. Our fan coil production line
Every fan coil has strict production process, including assembly, testing, packing.
8. FAQ
Q: Can I have a sample for testing before ordering products?
A: Yes, you can. And you are warmly welcomed to visit our factory before PO.
Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
Q: How to properly install the fan coil unit?
A: We have very detailed user manual and installation instructions, also can be directly telephone or online video guidance.
9. Our OEM and ODM service:
EUROSTARS was established in 2006, has a professional technical team to research and develope HVAC products. We offer OEM/ODM service to our clients.
Now EUROSTARS collaborate with our clients in the following ways:
(1)Produce EUROSTARS standard products under clients' brand.
(2)Modify the products to satisfy clients' personalized requirements.
(3)If clients have their own idea and design of the products, EUROSTARS can actualize it and modify it make it easy for mass production.
(4)Based on strong capability of research and development, EUROSTARS can work together with clients to design and produce a totally new products.
10. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..