Water Cooled Chiller Food Industrial Air Cooled Water Chiller

Product Details
Customization: Available
Type: Air-Cooled
Cooling Method: Air-cooled
Still deciding? Get samples of US$ 1600/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
  • Water Cooled Chiller Food Industrial Air Cooled Water Chiller
  • Water Cooled Chiller Food Industrial Air Cooled Water Chiller
  • Water Cooled Chiller Food Industrial Air Cooled Water Chiller
  • Water Cooled Chiller Food Industrial Air Cooled Water Chiller
  • Water Cooled Chiller Food Industrial Air Cooled Water Chiller
  • Water Cooled Chiller Food Industrial Air Cooled Water Chiller
Find Similar Products

Basic Info.

Model NO.
ESSA-30IDTN
Selected Voltage
220~460V-50Hz/60Hz-3pH
Compressor Number
1
Noise Level
Low
Application Fields
Plastic
Application Machine
CNC Machine Tools
Certification
CE
Condition
New
Compressor
Copeland, Danfoss, SANYO
Expansion Valve
Danfoss, Emerson
Controller
Microcomputer Control Punp
Evaporator
Plate, Shell Tube, Coil in Tank
Tank
Stainless Steel, Unpressurized
Refrigerant
R407c, R22, R134A, R404A
Service
OEM, ODM
Color
Blue White
Condenser
Aluminum Finned Copper Tube
Water Pump
Cnp
Fan
Axial
Cabinet
Anti-Corrosion
Solenoid Valve
Optional Castel
Transport Package
Wooden Case
Specification
Refirgerant R407C
Trademark
ESACIR
Origin
Shenzhen
HS Code
8418692090
Production Capacity
3000 Units Per Year

Product Description

Water Cooled Chiller Food Industrial Air Cooled Water Chiller

1. Air cooled industrial chiller applications


Eurostars industrial chillers are depended upon to serve the process cooling needs of a wide variety of industries, and are selected due to their advanced designs which are focused on energy efficiency, reduction of water consumption, reduced maintenance, and improved reliability of both the cooling system and the processes and equipment it serves. It is widely used for the following industry:
(1)Plastics:
(2)Automobile and Mechanical Engineering
(3)Food and Beverages:
(4)Medical
(5)Metal working
(6)Lasers
(7)Paper and related
(8)Others

2. Eurostars air cooled water chiller main components
(1)Refrigerant Circuit:

*R407C, R134A refrigerant
  - Non-Ozone Depleting
  - Low global warming impact
*Hermetic compressor  *Air-cooled condenser with finned tubes  *Propeller fan(s) induced air flow
*Refrigerant sight glass  *Filter-drier                         *Thermostatic expansion valve
(2)Electrical:
*Control cabinet  *Process pump motor starter  *Compressor contactor
(3)Coolant Circuit:
*Centrifugal pump     *Insulated non-ferrous reservoir(tank lid is standard )
*Reservoir level gauge  *Standard ZG process fittings(NPT is optional for America)
(4)System Limit Devices:
*High refrigerant pressure   *Low refrigerant pressure   *Process pump motor overload
(5)Frame Construction:
*Heavy steel galvanized painted with PU (Stainless steel sheet metal is optional)
*Removable cover panel    *Compact physical size   *Casters - for portability
Water Cooled Chiller Food Industrial Air Cooled Water Chiller

3. Eurostars air cooled industrial chiller features

(1)R22,R407c, R134a, R404a,R410A are available;
(2)Adopt international brands compressors : SANYO, COPELAND, DANFOSS, etc ;
(3)High-quality stainless steel multi-stage centrifugal pumps and stainless steel tanks(OPTIONAL);
(4)High efficiency finned tube condenser, ensure that the chiller can work properly;
(5)Using international brand Electrical components, and famous branded microcomputer temperature controller ;
(6)Multiple protection devices; ensure stable operation for many years;
(7)Wide variable range of frozen water, to meet different user requirements;
(8)Using ethylene glycol as the carrier refrigerant is more or less the freezing water temperatures as low as -15 °C(optional);
(9)Mounted Casters for small models ,tank level alarm/switch

4. Eurostars air cooled industrial chiller technical data 
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Air Cooled Chiller Unit
Model      ESSA- 01ISSN 02ISSN 03ISTN 04ISTN 05ISTN 06ISTN 08IDTN 10IDTN 12IDTN
Item NO. 1 2 3 4 5 6 8 10 12
Rated Cooling Capacity KW 2.76  5.72  8.96  11.31  14.12  17.24  22.62  28.24  34.48 
USRT 0.78  1.63  2.55  3.22  4.02  4.90  6.43  8.03  9.81 
×1000 kcal/h 2.37  4.92  7.71  9.73  12.14  14.83  19.45  24.29  29.65 
Air Cooled Chiller Unit
Model      ESSA- 15IDTN 20IDTN 25IDTN 30IDTN 40IQTN 50IQTN 60IQTN
Item NO. 15 20 25 30 40 50 60
Rated Cooling Capacity KW 43.22 58.2 71.18 87.3 87.78 116.4 142.36 177.95 175.56
USRT 12.29  16.55  20.24  24.83  24.97  33.11  40.49  50.61  49.93 
×1000 kcal/h 37.17  50.05  61.21  75.08  75.49  100.10  122.43  153.04  150.98 
Remarks:
(1) Rated Cooling Capacity Based on:Evaporating temperature 7ºC;Condensing temperature 50ºC,Ambient DB=35ºC.
(2)Chilled Water Range: 5~25ºC;

5. Eurostars air cooled industrial chiller protection devices
(1)Motor overload protection
Including for compressor motors, water pump motors and fan motors.
There are some situations that will cause damage to motors in an industrial chiller, such as instable voltage, ambient temperature too high which mostly caused by poor ventilation, returning water temperature too high, etc. In these cases the motor running current will get higher than its safe range, which might damage the motor if keep it working. Built in protection for overload will shut down the chiller and warn you if the motors are working unhealthily.
(2)Compressor motor overheat protection
Compressor is the heart of an industrial chiller, it reflects problem of the whole chiller unit. The situation causes compressor motor overheat includes poor ventilation, dusty condenser, refrigerant circuit blocking, lack of refrigerant, etc.
This alarm reminds you to check through the chiller unit, prevent it from burning out because of unhealthy working condition. 
(3)Discharge temperature overhigh protection
Discharge temperature overhigh normally caused by high suction temperature, high compressor motor temperature, lack of refrigerant, etc. It works as supplementary of compressor motor overheat.
(4)High&low pressure protection
High pressure normally caused by poor ventilation, dusty condenser, refrigerant circuit blocking, etc.
Low temperature caused by lack of refrigerant, system blocking and so on.
(5)Returning water overheat protection
Chiller supply cold water to cool the production process, normally the returning water temperature will be 3ºC to 8ºC higher than supplied water. If the chiller is not creating cooling energy, or the chiller capacity is not enough for the application, the temperature in the circuit will get higher and higher. This will cause damage for the production even the equipment.
While a chiller got an alarm function for returning water temperature, we can learn the situation promptly and make reaction.
(6)Low water flow/level protection
For a chiller with no open-circuit water tank, there will be a water flow switch to make sure the water circuit is working, preventing both production process and chiller unit from harmed by circuit blocking or water leaking.
(7)Phase protection
If an industrial chiller was falsely wired, motors will revert, which is a serious problem for all the motors. Phase protection will remind you to connect the power in a right way.
(8)Anti-freezing protection
This function prevents the water in the circuit from freezing, so to make sure the cooling circuit working in a healthy condition. 

 
6. Industrial chiller application consideration
Eurostars offers over 10 years of experience designing and building process chillers for your industrial applications. Our industrial grade process chillers come as a complete packaged unit so they can be simply dropped in place and turned on. The internal tank helps maintain a cold water temperature to stable to prevent spikes in temperatures no matter how many of your processes are operating. Eurostars has experience in designing process chiller systems whether you are cooling bio-fuels or multiple pieces of equipment.

APPLICATION CONSIDERATIONS:

(1)Equipment Chiller:
Through our experience working with industrial processes we understand the importance of tight temperature control. Eurostars provides cost effective solutions through the optional use of variable frequency drives (VFDs) and recirculation tanks. All of our equipment chiller systems are expandable for future growth. 
(2)Process Chiller:
Eurostars offers a variety of redundancy options to ensure that your processes are always chilled when you need it. From multiple refrigeration circuits with standard lead-lag control to auto-changeover pumps, our units are designed to ensure that your process is continuously running. It is imperative that the chiller is able to meet the changing demand of your application. Digital scrolls, cylinder unloading, and hot gas bypass are just some of the capacity control options that we offer.
(3)Oil Chiller:
The industrial environment is harsh on machine tools, which makes keeping oil cool imperative. An overheating machine tool can lead to premature failure and long periods of downtime. Eurostars oil chillers are specifically designed for industrial machine tools to increase efficiency, reliability and lifetime.

 
7. Factory testing of Eurostars every chiller unit
(1)Pressurization and helium leak detection of refrigeration circuit
(2)Pressurization and leak testing of fluid circuit
(3)Chiller performance and power consumption at full load
(4)Proper operation of all controls, safety devices, and alarms
(5)Electrical tests according to standards

8. About Eurostars
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.

Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.

Water Cooled Chiller Food Industrial Air Cooled Water Chiller

Water Cooled Chiller Food Industrial Air Cooled Water Chiller

Water Cooled Chiller Food Industrial Air Cooled Water Chiller
9. Our new chiller assemble line
Water Cooled Chiller Food Industrial Air Cooled Water Chiller
Chiller production at our previous location
Water Cooled Chiller Food Industrial Air Cooled Water Chiller

10. Eurostars air cooled industrial chiller package and delivery

Our standard package is plastic film with plywood case for safe delivery and easy to load/unload.
Water Cooled Chiller Food Industrial Air Cooled Water Chiller
Water Cooled Chiller Food Industrial Air Cooled Water Chiller

11. Eurostars industrial chiller projects

We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..
Water Cooled Chiller Food Industrial Air Cooled Water Chiller
Water Cooled Chiller Food Industrial Air Cooled Water Chiller

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier