Water Cooled Chiller Industrial Food Machinery Water Chiller for Bakery
1. Eurostars industrial chiller protection devices
Motor overload protection |
Compressor motor overheat protection |
Phase protection |
Discharge temperature overhigh protection |
High&low pressure protection |
Returning water overheat protection |
Low water flow/level protection |
Anti-freezing protection |
2. Eurostars water cooled industrial chiller applications
plastic industries |
injection and blow molding |
metal working cutting oils |
welding equipment |
die-casting&machine tooling |
chemical processing |
pharmaceutical formulation |
Food&beverage processing |
paper&cement processing |
vacuum systems |
X-ray diffraction |
power generation stations |
analytical equipment |
semiconductors |
compressed air&gas cooling |
MRI machines and lasers |
3. Eurostars water cooled water chiller main components
Hermetic Compressor |
Industry leader, long lasting compressor with motor contactor |
Microprocessor Control |
Stand alone,simple, accurate control with over 10 years field testing |
Stainless Steel Brazed Plate Evaporator |
Corrosion resistant evaporator wrapped in closed cell insulation |
Shell and Tube Condenser |
Compact and highly efficient |
Stainless Steel Pump |
Fused, non-ferrous pump for process circulation |
Polyethylene Storage Tank |
Closed cell insulation for increase temperature control with reliable, corrosion resistant |
Painted Galvanized Steel Metal Cabinet |
Sturdy, corrosion resistance, professional appearance |
Insulated Process Fluid Lines |
Maximum thermal efficiency |
Factory Tested |
Ensures the unit meets the customer's performance designed criteria and arrives in working order |
Full Refrigerant Charge |
Hassle free and more efficient installation |
4.Factory testing of Eurostars every chiller unit
(1)Pressurization and helium leak detection of refrigeration circuit
(2)Pressurization and leak testing of fluid circuit
(3)Chiller performance and power consumption at full load
(4)Proper operation of all controls, safety devices, and alarms
(5)Electrical tests according to standards
5. Eurostars water cooled industrial chiller brief technical data
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Water Cooled Chiller Unit |
Model ESSW- |
03ISCN |
04ISCN |
05ISCN |
06ISCN |
08IDCN |
10IDCN |
12IDCN |
Item NO. |
3 |
4 |
5 |
6 |
8 |
10 |
12 |
Rated Cooling Capacity |
KW |
10.15 |
12.93 |
16.13 |
20.40 |
25.00 |
32.26 |
40.80 |
USRT |
2.89 |
3.68 |
4.59 |
5.80 |
7.11 |
9.17 |
11.60 |
×1000 kcal/h |
8.73 |
11.12 |
13.87 |
17.54 |
21.50 |
27.74 |
35.09 |
Water Cooled Chiller Unit |
Model ESSW- |
15IDCN |
20IDCN |
25IDCN |
30IDCN |
40IQCN |
50IQCN |
60IQCN |
Item NO. |
15 |
20 |
25 |
30 |
40 |
50 |
60 |
Rated Cooling Capacity |
KW |
49.23 |
66.21 |
80.44 |
99.56 |
132.42 |
160.89 |
199.12 |
USRT |
14.00 |
18.83 |
22.87 |
28.31 |
37.65 |
45.75 |
56.62 |
×1000 kcal/h |
42.34 |
56.94 |
69.18 |
85.62 |
113.88 |
138.37 |
171.24 |
Remarks:
(1) Rated Cooling Capacity Based on:Evaporating temperature 7ºC;Condensing temperature 40ºC.
(2)Chilled Water Range: 5~25ºC;
(3)Cooling Water Range: 20~40ºC.
6. Industrial chiller refrigerant changes and water recirculation system
7.The benefits of water cooled industrial chillers
Using Eurostars as your supplier for top-tier, quality water-cooled chillers brings with it numerous advantages for the busy manufacturer looking to get the most out of their production capabilities.
By using Eurostars water-cooled chillers in your business, you'll be able to:
*Quickly cool produced parts, resulting in less delay during production
*Increase the number of parts generated in a working day
*Produce more precise and consistent products
*Increase profitability due to sped-up production
*Utilize the process for numerous applications, including molding and hydraulics
Additionally, Eurostars water-cooled chillers help you avoid having to use air-cooled system, which often affected by ambient temperature. In some areas, ambient temp. in summer is very high, it has big impact on air cooled chiller operation, consume approximately 10% more power than a water-cooled unit due to wet surfaces transferring heat better than dry surfaces.
8. Eurostars Company Ceritifcate & Customer Visiting
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
(1)With more certificate
(2) Professional team with over more than 10 years industry knowledge
(3) Oversea installation.
(4) Customer-made accepted.
(5) Diamond member of Made-In-China
(6) Audited supplier by SGS
9. Our factory view
Modern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numerical control punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,. etc..
Chiller production at our previous location as below
10. Eurostars industrial chiller package and delivery
Our standard package is plastic film with plywood case for safe delivery and easy to load/unload.
11. Eurostars industrial chiller projects
We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..
12. Types of water chiller and the differences
As described, two different cooling mediums (air or water) can facilitate the transfer of the latent heat given up as the refrigerant changes from vapor to liquid. Thus, chillers can use two different types of condensers, air-cooled and water-cooled.
(1)Air-cooled condensers resemble the "radiators" that cool automobile engines. They use a motorized blower to force air across a grid of refrigerant lines. Unless they are specially designed for high-ambient conditions, air-cooled condensers require ambient temperatures of 95°F (35°C) or below to operate effectively.
(2)Water-cooled condensers perform the same function as air-cooled condensers, but require two steps to complete the heat transfer. First, heat moves from refrigerant vapor into the condenser water. Then, the warm condenser water is pumped to a cooling tower where the process heat is ultimately discharged to the atmosphere.
(3)Water-cooled chillers are typically intended for indoor installation and operation, and are cooled by a separate condenser water loop and connected to outdoor cooling towers to expel heat to the atmosphere.
(4)Air-cooled and evaporative cooled chillers are intended for outdoor installation and operation. Air-cooled chillers are directly cooled by ambient air being mechanically circulated directly through the machine's condenser coil to expel heat to the atmosphere.
13. Our warranty, technical support and failure claim procedures
(1) Warranty
a. Eurostars HVAC units delivered to customers are carefully examined and tested, with 48 hours trouble-free trial operation.
b. Eurostars HVAC units enjoy 1~1.5 years guarantee ever since B/L date.
(2)Technical support
a. Eurostars provide full technical support and training courses after equipment installation and commissioning.
b. 7*24 hours phone assistance on technical support.
c. Eurostars provide overseas guide installation,but not for free.
(3)Failure claim procedures
a. Detailed written failure description is required by fax or by mail, indicating the relevant equipment information and detailed description of failure.
b. Relevant pictures are required for failure confirmation.
c. Eurostars engineering and after-sales service team will check and form a diagnosis report.
d. Further trouble-shooting solutions will be offered to customers within 24 hours after receiving the written description and pictures.