Air Handling Unit Rooftop Packaged Unit

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
  • Air Handling Unit Rooftop Packaged Unit
  • Air Handling Unit Rooftop Packaged Unit
  • Air Handling Unit Rooftop Packaged Unit
  • Air Handling Unit Rooftop Packaged Unit
  • Air Handling Unit Rooftop Packaged Unit
  • Air Handling Unit Rooftop Packaged Unit
Find Similar Products

Basic Info.

Model NO.
EST12HC4
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Air-Conditioning (HVAC)System
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
ISO, CE
Condition
New
Ahu Panels
Painted Steel, Gi, Ss Panels
Filters
Pre-Filter, Bag Filter, HEPA Filter
PU Foam Insulation
43-48kg/M3
Ahu Construction
25mm/ 50mm/ 75mm Double Skin
Base
C-Channel Hot DIP Base
Fan
Belt Drive Centrifugal Fans or Hygiene Plug Fan
Optional 1
VSD, VFD
Control
Option for PLC, Ddc
Ahu Framework
Aluminum
Cooling/ Heating Coil 1
Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr
Side Sliding Filter with Tracks
Yes
Optional 3
Ep, Chemical Filter, Plasma Sterilizer, Ak
Cooling/ Heating Coil 2
Copper Tube with Copper Fins (Cu/Cu), Gi/SUS Frame
Optional 2
Heat Recovery Wheel
Cold Bridge Free Design
Yes
Transport Package
Standard Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8415830000
Production Capacity
2000pieces/Year

Product Description

1. Eurostars air handling unit and air handler features
a) Structure:
1)Adopt Aloy frame, which is anodic oxidation treated to ensure good anti corrosion performance and nice outlook
2)Adopt no cold bridge design, frame mounted inside and jointed with high strength nylon tee
3)Smooth inner surface stop dirty to stay which can be applied in clean system

b) Panel
1)Adopt sandwich design panel , adopting PVC profile with good insulation performance
2)Adopt polyurethane foaming , foaming condensity is 48kg/m3 prevent heat to transfer.
3)Adopt double skin colorful steel panel, SUS panel and Salinization steel are for option
4)Panel thickness :25mm is for standard. 50mm is optional.

c) Perfect tightness
1)Adopt rubber double seal for frame and panel to guarantee good elasticity and anti-aging performance
2)Adopt hollow rubber with positive -negative pressure follow-up; it will be compressed tightly no matter with positive or negative pressure
3)Adopt Special aluminum alloy system linking piece to fix on the frame by screws ensure reliable performance
4)Casing air leakage is less than 1% under 1000Pa under standard working condition

d) High heat transfer efficiency heat exchanger
1)Adopt seamless copper tube and aluminum fin heat exchanger
2)Adopt 4 rows, 6rows, 8rows coil. Standard Aluminum fin space is 2.5mm, non standard fin space is for option
3)Coil rows, fin space, circuit No. can be calculated by selection program for different working condition.
 4)Unique coil distributing design ensures water drainage thoroughgoing and reduce possibility of coil frost crack

e) Drain pan
Dry type condensate drain pan with drainage slop is adopted to ensure good drainage performance and the drain pan is insulated to prevent condensation.

2.Eurostars Air handler,air handling unit, ahu application
1)Eurostars modular air handling units is a new type of air handling equipment, based many years of experience accumulated in the production of central air conditioning research and development independent.
Have good-looking appearance, compact structure, easy installation and maintenance, good overall performance, low leakage etc .characteristics.
2)Can according to customer requirements to provides a combination of multiple functional segments, widely be used in industrial air handling places such as electronic instruments, precision machinery manufacturing, textiles, chemicals, cigarettes, pharmaceuticals, power plants, etc., are also suitable for commercial buildings, restaurants, supermarkets, theaters, exhibition centers stadiums, shopping malls, hotels, office buildings and other commercial and civilian large and medium-sized public building


3.Air handler technical data, Assembly drawing diagram and photo
Horizontal Air Handling Unit(Return Air Condition-4 Rows)
Model Air Flow   Total
Pressure
Power Input Return Air
Cooling Capacity Heating Capacity Water Flow  Water Resistance Water inlet/outlet pipe Diameter
*1000CMH Pa kW kW L/min kPa DN
EST10HC4 10 350 2.2 60.4 84 172.8 18.6 50
EST12HC4 12 400 3 73 101.7 209.4 21.6 50
EST15HC4 15 400 4 98.6 138.9 282.6 22.5 65
EST18HC4 18 400 5.5 118.3 165 339.6 24.5 65
EST20HC4 20 400 5.5 139.5 194.4 400.2 30.4 65
EST23HC4 23 400 5.5 157.9 219.9 456 25.5 65
EST25HC4 25 400 7.5 169.5 236.3 486.6 37.2 80
EST28HC4 28 500 2*4 186.3 259.7 534 26.5 80
EST30HC4 30 500 2*5.5 199.3 277.9 571.8 22.5 2*65
EST35HC4 35 500 2*5.5 235.7 328.3 676.2 29.4 2*65
EST40HC4 40 500 2*5.5 271.2 378 778.2 34.3 2*65
EST45HC4 45 500 2*7.5 286.2 398.8 821.4 40.2 2*65
EST50HC4 50 600 2*11 322.7 449.8 925.8 51.9 2*80
NOTE:
  1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC;
  2. Return air: Heaing: Air in 15ºC DB,Hot water in: 60ºC.
Air Handling Unit Rooftop Packaged Unit
4. Eurostars air handling unit , air handler range or series
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modular Modulus Air Handling Unit-multi-function air handling unit
Air Handling Unit Rooftop Packaged Unit
5. Components-air handling unit or air handler

Casing Panel and Insulation
• Double skin construction is provided by sandwich type panels comprising inner and outer painted steel skins and polyurethane foam with minimum 48kg/m3 density, providing a good thermal and acoustical performance
• The gasket liner between the panels and frame ensures the air leakage rate to comply with GB/T 14294 clean air conditioning requirement
• The factory painted steel sheet covered with 6 insulation coatings, complies to 500h salt spray testing, showing an excellent corrosion protection performance
Air Handling Unit Rooftop Packaged Unit
Frame
•Penta-post extra heavy gauge aluminum profiles and strong fiber-reinforced PE corner connection forming the structural  frame
• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation
• Thermal bridge free design, the profiles filled with polyurethane foam for insulation
• Anodizing surface treatment for profiles, corrosion-resistant
• Stainless steel frame available
Air Handling Unit Rooftop Packaged Unit
Famous Brand Blower and Motor
•Energy saving Fan with low speed and low noise
•Type: Direct driven / Belt driven
            Forward curve and backward curve
            Centrifugal fan and EC plug fan
•Brand: Nicotra, Kruger, Deton, Yilida available
•Low noise long life Motor
•Brand: Siemens, ABB and Teco available
Air Handling Unit Rooftop Packaged Unit
Shock Absorber
•High quality spring isolators 
•Protect the unit during transportation
•Guard lock for fan start up
•Eliminate shock and noise during operation

Cooling/ Heating Coil
•Large coil face area with low air speed
•Various anti-corossion coating for option, Electrophoresis and Heresite coating available
•Type: Copper tube with Aluminium fins (Cu/Al), GI/SUS frame
            Copper tube with Copper fins (Cu/Cu), GI/SUS frame
•Rows: 4R/6R(can be 2R+4R design)/8R (can be 4R+4R design)
Copper Tube Protection
•Every mounting hole filled up glass cement to prevent copper tube damage during transportation and operation
Air Handling Unit Rooftop Packaged Unit
High efficiency filter
Filters are to remove particles and contaminants of various sizes from the air. The type of air filter being used will very much depend on the application of the system.
Panel Filter is a flat and rectangular in shape and provides a minimum low efficiency filtration which is acceptable to the air conditioning industry. The high velocity filter is arranged vertically whereas the low velocity filter is arranged in V shape. Typical air velocity that moves through the filters is in the range of 2-3 m/s.
Air Handling Unit Rooftop Packaged Unit
Stainless Steel Drain Pan
• Slop type design, no drain water carryover and keep the pan dry
• Avoid the micro-organisms growth inside the drain pan
Antimicrobial Drain Pan is offered as option
• SteriTouch technology Drip Pan Coating
• Antimicrobial surface
• Good exterior durability and corrosion resistance
• Excellent adhesion
• Non-toxic, comply with BS476 part 7
Air Handling Unit Rooftop Packaged Unit
Electrical control cabinet(optioanl)
•According to the requirements and functions of the unit to design the control console or cabinet
•Auto control each section of the unit to make sure the temperature, humidity and cleaness 
•High quality and international brand electrical elements
•DDC and PLC available

6.Why choose us?
Eurostars offers One Stop Solutions for:
•Pharmaceuticals industry
•Electronics industry
•Automobile industry
•Printing and food industry
•Commercial building
•VOC treatment and environment protection
•Indoor air quality
•Marine ventilation
Air Handling Unit Rooftop Packaged Unit
7.FAQ
Q:What is air handler?
A: An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system.
 
Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU. Sometimes AHUs discharge (supply) and admit (return) air directly to and from the space served without ductwork.

Small air handlers, for local use, are called terminal units, and may only include an air filter, coil, and blower; these simple terminal units are called blower coils or fan coil units.

A larger air handler that conditions 100% outside air, and no recirculated air, is known as a makeup air unit . An air handler designed for outdoor use, typically on roofs, is known as a packaged unit or rooftop unit .

Q: What information do you need to provide in order to get a quotation?
A: Generally, we need to know following items:
-Cooling Capacity in KW or RT or Btu
-Cold water conditions if available is better
- Local ambient temperature conditions
-Application
-Electrical power supply, such as 380V-3Phase-50HZ or 440V-3Phase-60HZ or others.
 
If can not give full answers for above items, we can via another way, such as room or building drawing,application,etc
Q: Can I have a sample for testing before ordering products?
A: Yes, you can.And you are warmly welcomed to visit our factory before PO.

Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines

8.Customer visit us
Air Handling Unit Rooftop Packaged Unit
9.Air handling unit,air handler delivery or container loading
Air Handling Unit Rooftop Packaged Unit
10.Installation instruction or installation photo, project photos
Air Handling Unit Rooftop Packaged Unit

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier