• High Static Pressure HVAC System Air Handling Equipment
  • High Static Pressure HVAC System Air Handling Equipment
  • High Static Pressure HVAC System Air Handling Equipment
  • High Static Pressure HVAC System Air Handling Equipment
  • High Static Pressure HVAC System Air Handling Equipment
  • High Static Pressure HVAC System Air Handling Equipment

High Static Pressure HVAC System Air Handling Equipment

Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Corrosion Durability: Higher
Operating Voltage: 380/400 VAC
Noise Level: Low
Application Fields: Air-Conditioning (HVAC)System
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
EST4VC4
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
ISO, CE
Condition
New
Filters
Pre-Filter, Bag Filter, HEPA Filter
Ahu Construction
25mm/ 50mm/ 75mm Double Skin
Ahu Panels
Painted Steel, Gi, Ss Panels
Base
C-Channel Hot DIP Base
Control
Option for PLC, Ddc
Cooling/ Heating Coil 2
Copper Tube with Copper Fins (Cu/Cu), Gi/SUS Frame
Optional 3
Ep, Chemical Filter, Plasma Sterilizer, Ak
Ahu Framework
Aluminum
Optional 2
Heat Recovery Wheel
Side Sliding Filter with Tracks
Yes
Cooling/ Heating Coil 1
Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr
PU Foam Insulation
43-48kg/M3
Fan
Belt Drive Centrifugal Fans or Hygiene Plug Fan
Cold Bridge Free Design
Yes
Optional 1
VSD, VFD
Transport Package
Standard Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8415830000
Production Capacity
2000pieces/Year

Product Description

1. Eurostars air handling unit and air handler features
1) Complying with above China Standard
2) Choose best materials, main components are from China top brand or imported.
3) The modular casing design, easy interchanging each other. easy install, easy transport, easy maintenance.
4, Unique no-cold-bridge design, improve the insulation and air tightness, total air leak rate ≤2.5%;
5) With dynamic balanced double inlet Centrifugal fan, with good air dynamic features, and accurate working, high efficiency, low vibration, low noise etc.
6) High efficient heat exchanger coil, ensure to provide the enough cooling capacity to the unit. And also high efficient breakwater panel is provided if required, water flow in coil ≤3×10-4kg/kg
7) Strong structure, good looking and permanent color.
8) Reasonable inside structure, with the suitable space for maintenance and cleaning.
9) Casing sheet: Provide double-skin construction constructing Sandwich type comprising 0.5mm thick galvanized internal and external skins and with 30mm thick polystyrene insulation of minimum 45kg/m3 density. Good airproof material is use between the casing and the frame to reduce the rate of the air leak.
10) The combined air handling units are modular designed ,each modular can be used independently and can also work together and company with fan coil units to add refresh air. Not only reduce operation costs and energy saving, but also optimize air quality and create a cognitive indoor space to meet the human health requirements


2.Eurostars Air handler,air handling unit, ahu application
1)Eurostars modular air handling units is a new type of air handling equipment, based many years of experience accumulated in the production of central air conditioning research and development independent.
Have good-looking appearance, compact structure, easy installation and maintenance, good overall performance, low leakage etc .characteristics.
2)Can according to customer requirements to provides a combination of multiple functional segments, widely be used in industrial air handling places such as electronic instruments, precision machinery manufacturing, textiles, chemicals, cigarettes, pharmaceuticals, power plants, etc., are also suitable for commercial buildings, restaurants, supermarkets, theaters, exhibition centers stadiums, shopping malls, hotels, office buildings and other commercial and civilian large and medium-sized public building


3.Air handler technical data, Assembly drawing diagram and photo
Vertical Air Handling Unit(Return Air Condition-4 Rows)
Model Air Flow   Total
Pressure
Power Input Return Air
Cooling Capacity Heating Capacity Water Flow  Water Resistance Water inlet/outlet pipe Diameter
*1000CMH Pa kW kW L/min kPa DN
EST3VC4 3 300 0.55 18.7 26.1 53.4 12.7 32
EST4VC4 4 300 0.75 26 36.2 74.4 14.7 32
EST5VC4 5 350 1.1 32.3 44.8 92.4 14.7 40
EST6VC4 6 350 1.5 37.3 52.1 106.8 19.6 40
EST7VC4 7 350 1.5 43.9 61.3 126 28.4 50
EST8VC4 8 350 2.2 50.6 70.5 145.2 29.4 50
EST10VC4 10 350 2.2 60.4 84 172.8 18.6 50
EST12VC4 12 400 3 73 101.7 209.4 20.6 50
EST15VC4 15 400 4 98.6 138.9 282.6 22.5 65
EST18VC4 18 400 5.5 118.3 165 339.6 24.5 65
EST21VC4 21 400 5.5 139.5 194.4 400.2 30.4 65
EST25VC4 25 400 7.5 169.5 236.3 486.6 34.3 80
Vertical Air Handling Unit(Return Air Condition-6 Rows)
Model Air Flow   Total
Pressure
Power Input Return Air
Cooling Capacity Heating Capacity Water Flow  Water Resistance Water inlet/outlet pipe Diameter
*1000CMH Pa kW kW L/min kPa DN
EST3VC6 3 300 0.55 24.3 31.5 69.6 16.7 32
EST4VC6 4 300 0.75 31.6 40.9 90.6 28.4 40
EST5VC6 5 350 1.1 39.3 50.7 112.2 30.4 40
EST6VC6 6 350 1.5 45.6 59.1 130.8 14.7 50
EST7VC6 7 350 1.5 54 69.9 154.8 17.6 50
EST8VC6 8 350 2.2 62.8 81.3 180 21.6 50
EST10VC6 10 350 2.2 78.7 101.8 225.6 33.3 50
EST12VC6 12 400 3 94.4 122.1 270.6 30.4 65
EST15VC6 15 400 4 119.3 154.4 342 38.2 65
EST18VC6 18 400 5.5 143.1 185 410.4 40.2 65
EST21VC6 21 400 5.5 167.8 217.1 480.6 41.2 80
EST25VC6 25 400 7.5 203.6 263.4 583.8 45.1 80
NOTE:
  1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC;
  2. Return air: Heaing: Air in 15ºC DB,Hot water in: 60ºC.

High Static Pressure HVAC System Air Handling Equipment
4. Eurostars air handling unit , air handler range or series
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modular Modulus Air Handling Unit-multi-function air handling unit
High Static Pressure HVAC System Air Handling Equipment
5. Components-air handling unit or air handler

•Galvanized steel(GI) and stainless steel(SS) available

•Double skin, 25~50mm PU insulation
High Static Pressure HVAC System Air Handling Equipment
Frame
•Penta-post extra heavy gauge aluminum profiles and strong fiber-reinforced PE corner connection forming the structural  frame
• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation
• Thermal bridge free design, the profiles filled with polyurethane foam for insulation
• Anodizing surface treatment for profiles, corrosion-resistant
• Stainless steel frame available

Famous Brand Fan and Motor
• Fan selection based on the air flow and air static requirement  is done by fan selection software
• Direct driven/ belt driven, forward curve/ backward curve centrifugal fans, and EC fan is available for option
• Nicotra, Kruger, Deton, Yilida is offered as option
• Motor is TEFC type, class F insulation and IP54 or IP55 protection, energy saving and stable operation
• Mounted on an adjustable slide for belt tension adjustment
• Variable frequency drive (VFD) motor is available
• Siemens, ABB, WEG, TECO is offered as option
High Static Pressure HVAC System Air Handling Equipment

Vibration Eliminator
• To reduce the transmission of vibration and noise, fan and motor are installed on an independent complete base frame
• The complete base frame is isolated by deflection type spring isolators
• This unique structure not only reduce the vibration and noise, but also protect fan and motor during transportation
High Static Pressure HVAC System Air Handling Equipment
High Efficiency Cooling and Heating Coil
• All coils calculation and selection is done by selection software to match the required conditions
• Large coil face area ensures maximum heat transfer rate
• All coils tested at 30bar pressure underwater 24 hours
• Various corrosion resistance coils for option:
-Cooper tube with cooper fins coil
 -Epoxy coated fins coil
 -Electrophoresis fins coil
-Heresite coated coil
High Static Pressure HVAC System Air Handling Equipment
High efficiency filter
Filters are to remove particles and contaminants of various sizes from the air. The type of air filter being used will very much depend on the application of the system.
Panel Filter is a flat and rectangular in shape and provides a minimum low efficiency filtration which is acceptable to the air conditioning industry. The high velocity filter is arranged vertically whereas the low velocity filter is arranged in V shape. Typical air velocity that moves through the filters is in the range of 2-3 m/s.

HEPA Filter is very efficient and is able to achieve efficiencies up to 99.97%, removing minute particles and airborne bacteria from the air. It is usually used in clean room applications such as semiconductor production floor, operating theaters and critical processes.

Electrostatic Filter is used to remove particles from the air by using highly charged electrodes that ionized the air.
Bag Filter is able to remove dust particles and is thrown away after use.
Roll Filter is used for high velocity filtration where the used part is rolled up automatically/manually.
High Static Pressure HVAC System Air Handling Equipment
Stainless Steel Drain Pan
• Slop type design, no drain water carryover and keep the pan dry
• Avoid the micro-organisms growth inside the drain pan
Antimicrobial Drain Pan is offered as option
• SteriTouch technology Drip Pan Coating
• Antimicrobial surface
• Good exterior durability and corrosion resistance
• Excellent adhesion
• Non-toxic, comply with BS476 part 7

High Static Pressure HVAC System Air Handling Equipment
Electrical control cabinet(optioanl)
•According to the requirements and functions of the unit to design the control console or cabinet
•Auto control each section of the unit to make sure the temperature, humidity and cleaness 
•High quality and international brand electrical elements
•DDC and PLC available

6.Why choose us?
EUROSTARS Advantages: 

1) The Proof of Quality: Now we have customers in different countries and places, such as Mexico, Australia, New Zealand, Singapore, Argentina, Middle- East, Africa…
2) The Guarantee of Quality: Reasonable design, Professional technicians, Stable production workers, Full-scale
 Equipments, Strict QA & QC system…
3) Custom-made Design: We supply our design drawing according to customer practical situation
4) Technique Support: 
 Walk in cold room: we supply our diagrammatic drawing, feel easier for installation.
 Cold storage warehouse: We have professional engineers who can go aboard to supply technology support and direction, until  turn key for our customers. 
5)International Trade Operation: We have concentrated on international trade of cold storage room line for many years, accumulated various experience from different customers of different countries. So we can update our operation in time according to our customers and new rules. It is helpful to clear custom and save cost and time for our customers.


High Static Pressure HVAC System Air Handling Equipment
7.FAQ
Q: Can I have a sample for testing before ordering products?
A: Yes, you can.And you are warmly welcomed to visit our factory before PO.

Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines


8.Customer visit us
High Static Pressure HVAC System Air Handling Equipment
9.Air handling unit,air handler delivery or container loading
High Static Pressure HVAC System Air Handling Equipment
10.Installation instruction or installation photo, project photos
High Static Pressure HVAC System Air Handling Equipment


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now