Heat Pump Fan Coil Duct installation Concealed Fan Coil Unit
1. Horizontal concealed high ESP ducted fan coil general description
Product Type |
High External Static Pressure Ducted Fan Coil Unit |
ESP |
120Pa (75Pa, 80Pa, 100Pa also optional) |
Pipe System |
2 pipes or 4 pipes |
Cooling Capacity |
9KW ~ 12.6KW (2 pipe system) |
Heating Capacity |
13.5KW ~ 18.9KW (2 pipe system) |
Cooling Capacity |
9KW ~ 12.6KW (4 pipe system) |
Heating Capacity |
6.5KW ~ 9.1KW (4 pipe system) |
2. Fan coil unit series
1 |
Ceiling concealed fan coil unit |
2 |
High ESP ducted fan coil unit |
3 |
Universal concealed fan coil unit |
4 |
Floor standing exposed fan coil unit |
5 |
Ultra thin exposed fan coil unit |
6 |
Ceiling exposed fan coil unit |
7 |
Ceiling cassette fan coil unit |
8 |
Ceiling exposed & floor standing fan coil unit |
9 |
Wall mounted fan coil unit |
3. High ESP ducted fan coil unit main parts
(1)Casing
Panels and frame are made of galvanized steel, properly punched for fixing both accessories and the unit itself, either to wall (vertical version) or ceiling(horizontal version).
(2)Cooling/Heating Coil
The coils are made of seamless tubes expanded into aluminum fins in continuous block. The connections have brass headers with female fittings and provided with easily.
accessible vent and drainage valve.
(3)Fan deck
The fan decks are composed of double suction centrifugal fans with metal impellers and 3-speed fan motors. Each fan motor assembly is dynamically balanced.
(4)Filter
The easily removable filter is made of filtering honeycomb polypropylene fabric and supported by an aluminum or plastic frame.
(5)Drip tray
The drip trays are made from sheet metal treated with polyester powder coating to ensure total resistance to atmospheric agents. The "L" type tray makes the units suitable for both vertical and horizontal installation.
(6)Electrical connection box
All electric wires are connected to enclosed electrical terminal block, can be situated on the opposite side to the water connections.
4. Ceiling horizontal concealed high static pressure fan coil unit technical specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
High ESP Ducted Fan Coil Unit(A Style) |
Model EST~ |
1000HP2 |
1200HP2 |
1400HP2 |
|
|
1000HP4 |
1200HP4 |
1400HP4 |
Air flow (m3/h) |
H |
1700 |
2040 |
2380 |
|
|
1700 |
2040 |
2380 |
M |
1280 |
1550 |
1800 |
|
|
1280 |
1550 |
1800 |
L |
860 |
1050 |
1280 |
|
|
860 |
1050 |
1280 |
Static pressure |
Pa |
120 |
100 |
80 |
|
|
120 |
100 |
80 |
Rated cooling capacity |
H |
TH(W) |
9000 |
10800 |
12600 |
|
|
9000 |
10800 |
12600 |
SH(W) |
6705 |
8046 |
9387 |
|
|
6705 |
8046 |
9387 |
M |
TH(W) |
7290 |
8748 |
10206 |
|
|
7290 |
8748 |
10206 |
SH(W) |
5759 |
6911 |
8063 |
|
|
5759 |
6911 |
8063 |
L |
TH(W) |
5670 |
6804 |
7938 |
|
|
5670 |
6804 |
7938 |
SH(W) |
4649 |
5579 |
6509 |
|
|
4649 |
5579 |
6509 |
Rated heating capacity |
H |
W |
13500 |
16200 |
18900 |
|
|
6500 |
7800 |
9100 |
M |
10395 |
12474 |
14556 |
|
|
5090 |
6110 |
7130 |
L |
8168 |
9801 |
11435 |
|
|
4080 |
4900 |
5720 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
5.About EUROSTARS?
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Webiste 1: http://eurostarschiller.en.made-in-china.com/
Website 2: http://eurostarschiller.en.made-in-china.com/
Instagram: https://eurostarschiller.en.made-in-china.com
Facebook: https://eurostarschiller.en.made-in-china.com
Youtube https://eurostarschiller.en.made-in-china.com
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
6. How to choose the fan coil?
(1) Firstly need to know the application site, for example, hotel room generally choose ceiling concealed fan coil, restaurant generally choose ceiling cassette fan coil, it depends on site requirements.
(2) If need to calculate cooling capacity, please get the acreage data.
(3) Confirm the pipe system: 2 pipe or 4 pipe according to the cooling and heating source.
7.Our service
Before-sale services:
(1)Tell clients how to use our products and matters needing attention.
(2)Guide clients to choose the best and economic product, recover the investment within short time.
(3)Site inspection if client require.
In-sale services:
(1)Quality control must be inspect strictly.
(2)In accordance with the agrements stipulated in the contract.
After-sale services
(1)If the project needs our installation guidance, we can send our engineer and translator. We can also send customers installation video to teach them how to fix and operate with our product.
(2)Usually, our product warranty is 12 months since BL date, within this warranty period, all parts broken will be responsible for our factory.
8. Fan coil unit package and delivery
For bulk order, our standard package is carton or honeycomb packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
9. Customers visit
10. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..