Type: Fan Coil Unit
Air Tube Material: Galvanized Sheet
Corrosion Durability: Higher
Operating Voltage: 110V/220~240V-50Hz/60Hz-1pH
Noise Level: Low
Application Fields: Restaurant/Hotel Room
Samples:
US$ 230/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
EST series
Mounting
Ceiling Concealed
Lifetime
>20 years
Certification
CE
Condition
New
Main Usage
Chiller, Heat Pump, Underfloor Heating
Air Outlet Static Pressure
120PA
Rows
4 Rows
Air Return
Backward/Downward
Filter
G4, F7 Optional
Production Time
20 Days for Bulk Order
Motor
AC or DC
Pipe System
Two Pipe and Four Pipe System
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Trademark
ESACIR
Origin
Guangdong, Prc.
HS Code
8415830000
Production Capacity
10000 PCS/Year

Product Description

Heat Pump Fan Coil Duct installation Concealed Fan Coil Unit

1. Horizontal concealed high ESP ducted fan coil general description

Product Type High External Static Pressure Ducted Fan Coil Unit
ESP 120Pa (75Pa, 80Pa, 100Pa also optional)
Pipe System 2 pipes or 4 pipes 
Cooling Capacity 9KW ~ 12.6KW (2 pipe system)
Heating Capacity 13.5KW ~ 18.9KW (2 pipe system)
Cooling Capacity 9KW ~ 12.6KW (4 pipe system)
Heating Capacity 6.5KW ~ 9.1KW (4 pipe system)
 
2. Fan coil unit series
Heat Pump Fan Coil Duct Installation Concealed Fan Coil Unit
1 Ceiling concealed fan coil unit
2 High ESP ducted fan coil unit
3 Universal concealed fan coil unit
4 Floor standing exposed fan coil unit
5 Ultra thin exposed fan coil unit
6 Ceiling exposed fan coil unit
7 Ceiling cassette fan coil unit
8 Ceiling exposed & floor standing fan coil unit
9 Wall mounted fan coil unit

3. High ESP ducted fan coil unit main parts
(1)Casing
Panels and frame are made of galvanized steel, properly punched for fixing both accessories and the unit itself, either to wall (vertical version) or ceiling(horizontal version).
(2)Cooling/Heating Coil
The coils are made of seamless tubes expanded into aluminum fins in continuous block. The connections have brass headers with female fittings and provided with easily.
accessible vent and drainage valve.
(3)Fan deck
The fan decks are composed of double suction centrifugal fans with metal impellers and 3-speed fan motors. Each fan motor assembly is dynamically balanced.
(4)Filter
The easily removable filter is made of filtering honeycomb polypropylene fabric and supported by an aluminum or plastic frame.
(5)Drip tray
The drip trays are made from sheet metal treated with polyester powder coating to ensure total resistance to atmospheric agents. The "L" type tray makes the units suitable for both vertical and horizontal installation.
(6)Electrical connection box
All electric wires are connected to enclosed electrical terminal block, can be situated on the opposite side to the water connections.

Heat Pump Fan Coil Duct Installation Concealed Fan Coil Unit

4. Ceiling horizontal concealed high static pressure fan coil unit technical specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com

High ESP Ducted Fan Coil Unit(A Style)
Model EST~ 1000HP2 1200HP2 1400HP2     1000HP4 1200HP4 1400HP4
Air flow (m3/h) H 1700 2040 2380     1700 2040 2380
M 1280 1550 1800     1280 1550 1800
L 860 1050 1280     860 1050 1280
Static pressure Pa 120 100 80     120 100 80
Rated cooling capacity  H TH(W) 9000 10800 12600     9000 10800 12600
SH(W) 6705 8046 9387     6705 8046 9387
M TH(W) 7290 8748 10206     7290 8748 10206
SH(W) 5759 6911 8063     5759 6911 8063
L TH(W) 5670 6804 7938     5670 6804 7938
SH(W) 4649 5579 6509     4649 5579 6509
Rated heating capacity  H W 13500 16200 18900     6500 7800 9100
M 10395 12474 14556     5090 6110 7130
L 8168 9801 11435     4080 4900 5720
Remarks:
(1)  Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)  Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature  60°C/50ºC.

 
5.About EUROSTARS?  
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Webiste 1: http://eurostarschiller.en.made-in-china.com/
Website 2: http://eurostarschiller.en.made-in-china.com/
 
Instagram: https://eurostarschiller.en.made-in-china.com
Facebook: https://eurostarschiller.en.made-in-china.com
Youtube https://eurostarschiller.en.made-in-china.com

Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.

Heat Pump Fan Coil Duct Installation Concealed Fan Coil Unit
Heat Pump Fan Coil Duct Installation Concealed Fan Coil Unit
6. How to choose the fan coil?
(1) Firstly need to know the application site, for example, hotel room generally choose ceiling concealed fan coil, restaurant generally choose ceiling cassette fan coil, it depends on site requirements.
(2) If need to calculate cooling capacity, please get the acreage data.
(3) Confirm the pipe system: 2 pipe or 4 pipe according to the cooling and heating source.
Heat Pump Fan Coil Duct Installation Concealed Fan Coil Unit


7.Our service
Before-sale services:
(1)Tell clients how to use our products and matters needing attention.
(2)Guide clients to choose the best and economic product, recover the investment within short time.
(3)Site inspection if client require.

In-sale services:
(1)Quality control must be inspect strictly.
(2)In accordance with the agrements stipulated in the contract.

After-sale services
(1)If the project needs our installation guidance, we can send our engineer and translator. We can also send customers installation video to teach them how to fix and operate with our product.
(2)Usually, our product warranty is 12 months since BL date, within this warranty period, all parts broken will be responsible for our factory.

 
8. Fan coil unit package and delivery
For bulk order, our standard package is carton or honeycomb packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
Heat Pump Fan Coil Duct Installation Concealed Fan Coil Unit

9. Customers visit
Heat Pump Fan Coil Duct Installation Concealed Fan Coil Unit

10. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..
Heat Pump Fan Coil Duct Installation Concealed Fan Coil Unit

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now