Floor Standing Exposed Ceiling Concealed Wall Cassette Fan Coil Unit
1. Ceiling cassette fan coil brief introduction and main applications
Four style ceiling cassette fan coil unit can be selected:
Cassette type with 4 way air discharge, drained pump, remote controller |
Cassette type with 4 way air discharge, drained pump, wired controller |
Cassette type with 1 way air discharge, drained pump, remote controller |
Cassette type with 1 way air discharge, drained pump, wired controller |
Product Type |
Ceiling Cassette Fan Coil Unit |
Motor |
AC (DC as optional) |
Air Outlet |
4 way air discharge (1 way,,360 angle degrees optional ) |
Pipe System |
2 pipes or 4 pipes |
Cooling Capacity |
2KW ~ 15KW (2 pipe system) |
Heating Capacity |
3.1KW ~ 24KW (2 pipe system) |
Cooling Capacity |
1.95KW ~ 13.2KW (4 pipe system) |
Heating Capacity |
1.95KW ~ 13.5W (4 pipe system) |
Showroom |
Shopping mall |
Restaurant & Bar |
Hotels |
Offices |
Building |
Clean room |
Library |
School |
Supermarket |
Exhibition hall |
Factory |
Apartments |
Dormitories |
2. Ceiling cassette fan coil unit main parts
Fan |
Centrifugal type, pass statically and dynamically balanced test |
Motor |
Single-phase motors are suitable for different voltages, DC option |
Drain pump |
High lift water drained pump drains out the condensate water |
Coil |
Hydrophilic blue aluminium fin around with copper tube |
Casing |
Galvanized steel casing for master unit; ABS cover panel |
3. Eurostars Fan coil unit series
1 |
Ceiling concealed fan coil unit |
2 |
High ESP ducted fan coil unit |
3 |
Universal concealed fan coil unit |
4 |
Floor standing exposed fan coil unit |
5 |
Ultra thin exposed fan coil unit |
6 |
Ceiling exposed fan coil unit |
7 |
Ceiling cassette fan coil unit |
8 |
Ceiling exposed & floor standing fan coil unit |
9 |
Wall mounted fan coil unit |
4. Ceiling cassette fan coil unit main features
(1)Silence design with low noise.
(2)Air flow direction can be changed to uniform cooling.
(3)No need for air duct.
(4)Special design of the air filter, the filter can be dismantled without special tools.
(5)Easy for clean and maintenance .
(6)Driving device and remote control device can be provided for the outlet plates.
(7)Lifting pump and coils can be provided for collecting condensed water.
(8)Compact design, suitable for strict space installation.
5. Ceiling cassette fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Cassette Fan Coil Unit (4-way 2 pipe system) |
Model EST~ |
200C2 |
300C2 |
400C2 |
500C2 |
600C2 |
800C2 |
1000C2 |
1200C2 |
1400C2 |
1600C2 |
Power supply |
220V-1PH-50/60HZ |
Air flow
(m3/h) |
H |
360 |
540 |
720 |
900 |
1080 |
1430 |
1780 |
2130 |
2480 |
1830 |
M |
290 |
390 |
525 |
670 |
775 |
1050 |
1290 |
1560 |
1810 |
2050 |
L |
190 |
270 |
350 |
440 |
540 |
720 |
870 |
1060 |
1290 |
1370 |
Static pressure |
Pa |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
Cooling capacity |
TH |
H |
W |
2000 |
3000 |
3800 |
4900 |
5800 |
7500 |
9800 |
11000 |
12000 |
15000 |
BTU/h |
6826 |
10239 |
12969 |
16724 |
19795 |
25598 |
33447 |
37543 |
40956 |
51195 |
SH |
W |
1400 |
2200 |
2850 |
3500 |
4250 |
5500 |
7150 |
8250 |
9100 |
11175 |
BTU/h |
4778 |
7509 |
9727 |
11946 |
14505 |
18772 |
24403 |
28157 |
31058 |
38140 |
TH |
M |
W |
1700 |
2550 |
3250 |
4150 |
4950 |
6400 |
8350 |
9350 |
10200 |
12450 |
BTU/h |
5802 |
8703 |
11092 |
14164 |
16894 |
21843 |
28499 |
31912 |
34813 |
42492 |
SH |
W |
1150 |
1800 |
2350 |
2850 |
3500 |
4550 |
5950 |
6850 |
7650 |
9560 |
BTU/h |
3925 |
6143 |
8021 |
9727 |
11946 |
15529 |
20307 |
23379 |
26109 |
32628 |
TH |
L |
W |
1400 |
2050 |
2600 |
3400 |
4000 |
5200 |
6750 |
7600 |
8300 |
10300 |
BTU/h |
4778 |
6997 |
8874 |
11604 |
13652 |
17748 |
23038 |
25939 |
28328 |
35154 |
SH |
W |
950 |
1400 |
1850 |
2300 |
2800 |
3600 |
4700 |
5450 |
6000 |
8400 |
BTU/h |
3242 |
4778 |
6314 |
7850 |
9556 |
12287 |
16041 |
18601 |
20478 |
28669 |
Heating capacity |
H |
W |
3100 |
4700 |
5900 |
7600 |
9000 |
11600 |
15200 |
17100 |
18600 |
24000 |
BTU/h |
10580 |
16041 |
20137 |
25939 |
30717 |
39591 |
51878 |
58362 |
63482 |
81912 |
M |
W |
2650 |
4000 |
5000 |
6450 |
7650 |
9850 |
12900 |
14550 |
15800 |
19900 |
BTU/h |
9044 |
13652 |
17065 |
22014 |
26109 |
12900 |
44028 |
49659 |
53925 |
67919 |
L |
W |
2100 |
3150 |
3950 |
5100 |
6050 |
7750 |
10200 |
11450 |
12450 |
15200 |
BTU/h |
7167 |
10751 |
13481 |
17406 |
20649 |
26451 |
34813 |
39079 |
42492 |
51878 |
Cassette Fan Coil Unit(4-way 4 pipe system) |
|
Model EST~ |
200C4 |
300C4 |
400C4 |
500C4 |
600C4 |
800C4 |
1000C4 |
1200C4 |
1400C4 |
1600C4 |
Power supply |
220V-1PH-50/60HZ |
Air flow
(m3/h) |
H |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
2720 |
M |
280 |
380 |
515 |
660 |
765 |
1040 |
1280 |
1550 |
1800 |
2040 |
L |
180 |
260 |
340 |
430 |
530 |
710 |
860 |
1050 |
1280 |
1360 |
Sta.pressure |
|
Pa |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
Cooling capacity |
TH |
H |
W |
1950 |
2950 |
3700 |
4800 |
5700 |
7350 |
9600 |
10800 |
11750 |
13200 |
BTU/h |
6655 |
10068 |
12628 |
16382 |
19454 |
25086 |
32765 |
36860 |
40103 |
45052 |
SH |
W |
1350 |
2150 |
2800 |
3450 |
4150 |
5400 |
7000 |
8100 |
8900 |
10000 |
BTU/h |
4608 |
7338 |
9556 |
11775 |
14164 |
18430 |
23891 |
27645 |
30376 |
34130 |
TH |
M |
W |
1650 |
2500 |
3200 |
4050 |
4850 |
6250 |
8200 |
9150 |
10000 |
11000 |
BTU/h |
5631 |
8533 |
10922 |
13823 |
16553 |
21331 |
27987 |
31229 |
34130 |
37543 |
SH |
W |
1150 |
1750 |
2300 |
2800 |
3450 |
4450 |
5850 |
6700 |
7500 |
37532 |
BTU/h |
3925 |
5973 |
7850 |
9556 |
11775 |
15188 |
19966 |
22867 |
25598 |
128097 |
TH |
L |
W |
1350 |
2000 |
2550 |
3350 |
3900 |
5100 |
6600 |
7450 |
8150 |
9100 |
BTU/h |
4608 |
6826 |
8703 |
11434 |
13311 |
17406 |
22526 |
25427 |
27816 |
31058 |
SH |
W |
950 |
1350 |
1800 |
2250 |
2750 |
3550 |
4600 |
5350 |
5900 |
6600 |
BTU/h |
3242 |
4608 |
6143 |
7679 |
9386 |
12116 |
15700 |
18260 |
20137 |
22526 |
Heating capacity |
H |
W |
1950 |
3000 |
3750 |
4850 |
5750 |
7400 |
9700 |
10900 |
11850 |
13500 |
BTU/h |
6655 |
10239 |
12799 |
16553 |
19625 |
25256 |
33106 |
37202 |
40444 |
46076 |
M |
W |
1700 |
2550 |
3200 |
4100 |
4850 |
6250 |
8200 |
9250 |
10050 |
11200 |
BTU/h |
5802 |
8703 |
10922 |
13993 |
16553 |
21331 |
27987 |
31570 |
34301 |
38226 |
L |
W |
1350 |
2000 |
2500 |
3250 |
3850 |
4950 |
6500 |
7300 |
7950 |
8750 |
BTU/h |
4608 |
6826 |
8533 |
11092 |
13140 |
16894 |
22185 |
24915 |
27133 |
29864 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
6.About EUROSTARS
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
(1)With more certificate
(2) Professional team with over more than 10 years industry knowledge
(3) Oversea installation.
(4) Customer-made accepted.
(5) Diamond member of Made-In-China
(6) Audited supplier by SGS
7. Production line and Customer visit
8. Our service
Before-sale services:
(1)Tell clients how to use our products and matters needing attention.
(2)Guide clients to choose the best and economic product, recover the investment within short time.
(3)Site inspection if client require.
In-sale services:
(1)Quality control must be inspect strictly.
(2)In accordance with the agrements stipulated in the contract.
After-sale services
(1)If the project needs our installation guidance, we can send our engineer and translator. We can also send customers installation video to teach them how to fix and operate with our product.
(2)Usually, our product warranty is 12 months since BL date, within this warranty period, all parts broken will be responsible for our factory.
9. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
10. Cassette fan coil installation instruction
11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..