Commercial Air Cooled Chiller for Air Conditioning System

Product Details
Customization: Available
Type: Air-Cooled
Cooling Method: Air-cooled
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
  • Commercial Air Cooled Chiller for Air Conditioning System
  • Commercial Air Cooled Chiller for Air Conditioning System
  • Commercial Air Cooled Chiller for Air Conditioning System
  • Commercial Air Cooled Chiller for Air Conditioning System
  • Commercial Air Cooled Chiller for Air Conditioning System
  • Commercial Air Cooled Chiller for Air Conditioning System
Find Similar Products

Basic Info.

Model NO.
ESSA-05STN
Unit Structure
Integral
Selected Voltage
220~480V-50Hz/60Hz-3pH
Compressor Number
1, 2, 3 or 4
Noise Level
Low
Application Fields
Air-Conditioning (HVAC)
Application Machine
Cooling
Certification
CE
Condition
New
Compressor
Copeland/Danfoss/Panasonic/SANYO
Working Ambient Termp.
15deg C~43deg C
Application
Cooling, Air-Conditioning (HVAC)
Structure
Monoblock Type
DC Inverter
Optional
Refrigerant
R407c/R410A, R134A Is Optional
Warranty
2 Years, 18 Months, 1 Year
Throttle Unit
Expansion Valve
Housing Material
Galvanized Steel
Evaporator
Tube in Shell Tank Type/Plate Type
Overseas Service
Available
Condenser
Blue Aluminum Fin Arround Copper Tube
OEM/ODM
Available
Power Source
Electric
Power Supply
50Hz, 60Hz(Optional)
Transport Package
Standard Export Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8418692090
Production Capacity
2000PCS/Year

Product Description

1.Application of scroll commercial air cooling water chiller
Used as air conditioning(often called commercial water chiller),such as used in hotel, theater, office building and supermarket, schools...


2.Eurostars Commercial Air Cooling Scroll Water Chillers Features:
1. Environmental friendly and safe
Electric parts and water system is completely cut off, ensuring security water use, no pollution to the atmosphere and free of greenhouse effect and it is the safest water heater
2. Energy-saving
3. Automatic intelligent control system
Adopting intelligent computerized automatic control system, no manual cost, easy to operate, convenient, make water chiller work safely and reliably. Control panel with modularized unit design can control more flexible heat pumps packs, with user-friendly operating system interface, easy to operate..
4. Widely used
Water chiller is applied to cold water for household and commercial use like families, schools, hospitals, shower center, etc.


3.Air Cooled Scroll Commercial Water Chiller Technical Datas
Air Cooled Chiller Unit(commerical type)
Model      ESSA- 05STN 10DTN 12DTN 20QTN 25QTN 20DTN 25DTN
Rated Cooling Capacity KW 14 28 34.5 58.2 66 58 67
USRT 4.0 8.0 9.8 16.6 18.8 16.5 19.1
×1000 kcal/h 12.0 24.1 29.7 50.1 56.8 49.9 57.6
Refrigerant R407C
Evaporator Tank Tube in Shell  Shell and Tube
Condenser Ripple Aluminum Fins around Cooper Pipe
                   
Model      ESSA- 25DTP 40QTN 50QTP 80DTP 100QTP 160QTP
Rated Cooling Capacity KW 66 106 130 230 290 460
USRT 18.8 30.1 37.0 65.4 82.5 130.8
×1000 kcal/h 56.8 91.2 111.8 197.8 249.4 395.6
Refrigerant R410A R407C R410A
Evaporator Shell and Tube 
Condenser Ripple Aluminum Fins around Cooper Pipe

4.Air Cooled Scroll Water Chiller Main Components Introduction
1)Copeland /Panasonic Compressor :High quality Scroll Compressor.
Commercial Air Cooled Chiller for Air Conditioning System


2)Fan: Well selected axial fan motor combined with large fan blade, which provide heavy air blow at low rotate speed, reducing vibration and noise.
Commercial Air Cooled Chiller for Air Conditioning System

3)Expansion Valve: SANHUA/Danfoss /Emerson Expansion valve, with more precise control of refrigerant flow system, which optimize heat pump working capacity and efficiency under different ambient conditions.
Commercial Air Cooled Chiller for Air Conditioning System

4)High Efficient water side heat exchanger:
a) Tube in shell tank type: Optimize design of both inner and outer screwed tube, it helps to increase heating exchange efficiency, and provide better heating capacity. The special design of liquid refrigerant circulating tube on the bottom of condenser ensures the heat pump system run smoothly in severe working condition.
b)Brazed-plate evaporator: made from stainless steel features a brand-new diagonal design to better utilize heat exchanging surfaces.
c)Shell and tube dry type evaporator: with inner grooved cooper tubes optimizes the cooling and heating efficiency.
Self-cleaning, high intensity, anti-shaking design and heat insulation covering material ensure shell and tube heat exchanger unstained,reliable,quiet,highly efficient.
Commercial Air Cooled Chiller for Air Conditioning System
5)Air Side Heat exchanger: Blue hydrophilic fin and copper tube heat exchanger.
Commercial Air Cooled Chiller for Air Conditioning System
6)AC contactor & Thermal relay: High quality FUJ/Schneider /EATON or other brand contactor and thermal relay can freely turn on/off more times.
7)Humanized PCB Design: Military level PCB components, intelligent controlling program reinforced a reliable operation of the heat pump unit. Special colored wiring design on the PCB provides great convenience in installation and further maintenance.
Commercial Air Cooled Chiller for Air Conditioning System
8)Noise Isolated Material: Using high quality aerial noise isolated material, noise and vibration is avoided perfectly(optional).


5. EUROSTARS Commercial Air Coooling Scroll Water Chiller Series

Commercial Air Cooled Chiller for Air Conditioning System
6.About US
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services; which be always here to provide following service:
1) Project system design;
2) Technical support;
3) Manufacturing production;
4) Delivery;
5) Installation;
6) Test and commissioning;
7) Repair and maintenance;
8) After sale service, etc


Commercial Air Cooled Chiller for Air Conditioning System
7.FAQ
Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines

Q:Are you a factory?
 Yes, we are a professional manufacturer for more than 13 years


Q:How do you check the goods?
We inspect all the materials when they arrive, and have spot inspection during production process. All goods will be tested and double inspected before delivery, providing 100% guarantee for clients.

Q:How and when can I get the quotation?
Send us the inquiry or leave us message. We will get back to you within 1 hour during the working time. All messages will be replied whenever they comes.

Q:What's your payment terms?
Usually we accept T/T or LC. 30% deposit. Other payment terms can be discussed when orders confirmed.

Q:Where is your factory Located? How can I visit there?
We located in Shenzhen, Guangdong Province, which is near Shenzhen International Airport. We can pick you up from the airport . You are warmly welcome to visit us

Q:Do you provide OEM service?
Yes! We provide OEM and ODM service.

Q:What's the lead time for your goods?
 Normally 25~30 workdays. For urgent orders, we can make special arrangement to fulfill your request. 


8.Customer visit us
Commercial Air Cooled Chiller for Air Conditioning System
9.Air cooled water chiller delivery or container loading
Commercial Air Cooled Chiller for Air Conditioning System

10. Installation instruction or installation photo, project photos

Commercial Air Cooled Chiller for Air Conditioning System

A,Place selection of installation Heat pump

 1). Heat pump should be installed in a large space, and have good air flow condition.
 2). Air inlet and outlet must be a clear road, the distance from barrier to inlet and outlet must be longer than 2m.
 3). Set drain ditch or drain outlet, so that can drain water easily.
 4). The installation base or bracket must be firm, make sure heat pump work balancely.
 5). Make sure heat pump is vertical, can't be slanted.
 6). Don't install heat pump at the place in where there is plenty of pollutional and corrosive gas or sand or fallen leaves.
 7). The installation place can't be near inflammable, flammable thing or fire.
 8). Installation:
---The installation base can be concrete construction, or steel bracket, and must use anti-vibration rubber pad, And the surface should be smooth.
---The design of installation base can be according to heat pump weight.
---The heat pump bottom should be fixed by bolt.
B,Pipe connection
The drain pipe and overflow pipe should be installed near drain ditch or drain outlet, easy to drain, and install drain water valve on drain pipe before magnetic valve there should be service valve on water pipe.
 If use plastic pipe (such as PPR pipe or ABS pipe), users should consider pipe expand and contract problem between heat pump and water tank.
 Water supply valve and cut-off valve maybe need insulation (according to local weather condition),avoid frost crack.
C,Water pipe system installation
Water pipe should be straight, and the arrange should be reasonable, reduce bend as little as possible. Reduce the water pipe resistance.
There can't be leaking at any place of pipe.
After all equipments and pipes installation finished, users should test water pressure, and drive air out, drain dirty out, make sure water cycle system is  clean. After confirm there is not any problem, then insulate all hot water pipes.
D,Power supply wiring
 220V heat pump use single phase power supply, 380V heat pump use three phase power supply, wire line is 3phase 4lines, A B C connects live line, N connects null line, E connect earth. Be sure not to connect N line to live line of power supply.
 1).When repairing, please turn power supply at "off" side.
 2).Power supply connecting process:make sure a equipment power supply is cut off before its installation is finished. Install power supply switch at suitable place, Use rubber hole for wiring line in electric box.
Power supply demand:
220V rated voltage±10%
380V rated voltage±10%
frequency:50Hz rated frequency±2%
 3).if power supply fluctuation is out of demand, please don't start your heat pump.

Commercial Air Cooled Chiller for Air Conditioning System
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now