None CFC Air Cooled Industrial Chiller with R407c CE Certificate Air Chiller

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 230V-460V/50-60Hz
Compressor Number: 1 or 2
Noise Level: Low
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ESGA series
Application Fields
Electroplating
Application Machine
CNC Machine Tools
Certification
CE
Condition
New
Water Chiller Compressor
Taiwan Hanberll
Water Chiller Controller
Punp or Siemens
Water Chiller Expansion Valve
Emerson
Transport Package
Standard Export Package
Specification
CE
Trademark
Eurostars
Origin
Guangdong, Prc
HS Code
8418692090

Product Description

1.Eurostars Water Chiller Features
1).The Chiller cooling capacity ranged from 100Kw to 800 Kw.
2). Adopt good quality famous brand HANBELL compressor,high efficiency, low noise, less 
  wearing and long life
3).With high efficiency condener and evaporator
4). World famous brand parts: such Danfoss/ ALCO expansion valve, FUJI contactor other brand like PUNP, Schneider,Siemens;
5). Water chillers have high COP;
6). Stable quality, long using life. 
7).Heat recovery(optional)can help user produce free hot water, which can be 55C
8). Can be widely used in different area,such as in commercial AC, Massage center, Hospital, Hotel, School, etc 
9). Strong unit base frame ensured the equipment stable operation 
10). Adopt leading brand PLC or SCM controller
11). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.
12).Standard model exclude water tank and water pump;but it can be custom-made based on client requirement,such as including chilled water pump,hot water pump and hot water tank;
13).Refrigerant is R407C,R22,but R410A,R134A also available.
14).Power and frequency supply:380~415V-3PH-50HZ;Can customize 220~480V-3PH-60HZ;
15). Chilled water range: 5°C to 20°C
 
2.Eurostars water chiller main parts photos and brand
None CFC Air Cooled Industrial Chiller with R407c CE Certificate Air Chiller


3.Eurostars water chiller protection devices
1)Phase reversion protection, 
2)Phase lack protection, 
3)Overload current protection,
4)Discharge air temp. protection, 
5)Low & High pressure protection, 
6)Low temp. protection, 
7)Water flow protection.
 
 
4.Eurostars water cooled chiller technical parameter

Refrigerant-R407C

Air Cooled Chiller Unit (Screw Type Compressor-one compressor)
 Model     ESGA- 40ISTN 55ISTN 75ISTN 90ISTN 100ISTN 110ISTN 120ISTN
Rated Cooling Capacity KW 136 198 263 311 360 393 424
USRT 38.68  56.31  74.80  88.45  102.39  111.77  120.59 
X 1000Kcal/h 116.96  170.28  226.18  267.46  309.60  337.98  364.64 
 Comp. lnput Power×Qty (KW) 37.2×1 51.8×1 68.7×1 76.4×1 89.2×1 97.5×1 106.8×1
Refrigerant  R407C
Power Supply  3φ-380V-50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit 1
Capacity Control (%) 0, 66, 100 0, 50, 75, 100
Refrigerant Charge (Kg) 30 42 56 68 78 84 93
Condenser Ripple Aluminum Fins Around Copper Pipe
Evaporator Dia.of Pipe (inch) 2-1/2" 3" 3" 3" 4" 4" 4"
Water Side Max Pressure  (MPa) 1
Chilled  Water Flow(m3/h) 23.4  34.1  45.2  53.5  61.9  67.6  72.9 
Water Pressure drop (kPa)  28 33 48 55 61 64 66
Axial Fan Air Flow×1000m3/h 40.2 56.8 80.4 85.2 120.6 120.6 160.8
Power×Qty (KW) 2.0×2 1.2×4 2.0×4 1.2×6 2.0×6 2.0×6 2.0×8


Air Cooled Chiller Unit (Screw Type Compressor-two compressor)
 Model     ESGA- 140IDTN 150IDTN 175IDTN 185IDTN 205IDTN 225IDTN 240IDTN
Rated Cooling Capacity KW 482 526 622 658 720 786 848
USRT 137.09  149.60  176.91  187.14  204.78  223.55  241.18 
X 1000Kcal/h 414.52  452.36  534.92  565.88  619.20  675.96  729.28 
 Comp. lnput Power×Qty (KW) 62.4×2 68.7×2 76.4×2 80.3×2 89.2×2 97.5×2 106.8×2
Refrigerant  R407C
Power Supply  3φ-380V-50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit 2
Capacity Control (%) 0, 25, 37.5, 50, 62.5, 75, 87.5, 100
Refrigerant Charge (Kg) 104 112 136 142 156 168 186
Condenser Ripple Aluminum Fins Around Copper Pipe
Evaporator Dia.of Pipe (inch) 5" 5" 3"×2 3"×2 4"×2 4"×2 4"×2
Water Side Max Pressure  (MPa) 1
Chilled  Water Flow(m3/h) 82.90  90.47  106.98  113.18  123.84  135.19  145.86 
Water Pressure drop (kPa)  42 54 44 52 54 55 65
Axial Fan Air Flow×1000m3/h 160.8 160.8 170.4 241.2 241.2 241.2 321.6
Power×Qty (KW) 2.0×8 2.0×8 1.2×12 2.0×12 2.0×12 2.0×12 2.0×16


5.Eurostars water chiller series
-Commercial Water Cooled Chiller
-Scroll type water cooled water chiller
-Screw type water cooled water chiller
-Flooded type water cooled water chiller
 
-Commercial Air Cooled Chiller
-Scroll type air cooled water chiller
-Screw type air cooled water chiller
 
-Industrial Chiller
-Air cooled industrial chiller(with heat recovery)
-Water cooled industrial chiller(with heat recovery)
-Glycol chiller (with heat recovery)
 
6.Eurostars water chiller loading in container photos
None CFC Air Cooled Industrial Chiller with R407c CE Certificate Air Chiller

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now