Cooling And Heating Ceiling Cassette Fan Coil Air Conditioner System
1.Ceiling cassette fan coil brief introduction
Fan coil unit is the terminal of central air conditioning system.It consists of panel, master unit with centrifugal fan and copper tube heat exchanger, etc. The cassette fan coil unit fan coil unit can be ceiling suspendedding installation with hanger or recessed installation, and suitable for those places that required delicate decoration. Exposing air outlet, which save space and easy maintenance. Widely used in hotels, restaurants, factories, hospitals, exhibition hall, shopping malls, office rooms and other industrial and civil construction of the combined air-conditioning system to meet the cooling, heating and other requirements.
Four style ceiling cassette fan coil unit can be selected:
Cassette type with 4 way air discharge, drained pump, remote controller |
Cassette type with 4 way air discharge, drained pump, wired controller |
Cassette type with 1 way air discharge, drained pump, remote controller |
Cassette type with 1 way air discharge, drained pump, wired controller |
2. Ceiling cassette fan coil unit main components
(1)Three-dimensional spiral wind blade ensures wind volume and thinner shape, and irregular wind blade pitch greatly reduces operating noise.
(2)The low-noise three-speed capacitor motor of well-known domestic brands is adopted, with imported precision ultra-low-noise rolling bearing.
(3)Circular heat exchanger design, wind uniformity, seamless copper tube and new high-efficiency corrugated double curved open window hydrophilic aluminum foil fin, optimize flow design and effectively improve heat transfer efficiency.
(4)Foam insulation, thickening foam insulation layer inside the fuselage, not easy to produce condensation beads in summer, not easy to corrode, and extend the service life.
(3) ZG3/4" pipe of water collecting head adopts forged brass structure, which is reliable and durable.
3. Ceiling cassette fan coil features
(1)Air flow:
*4-way air flowing, easy be installed inside of ceiling
*Unit can auto swing with a wide air flowing range,make the room temperature be uniform
(2)Low noise:
Large diameter centrifugal fan, super-silent operation; with high efficiency air flow and large air flow
(3)Efficient and energy saving
To maximize heat transfer and exchange efficiency, the unit features "C" type heat exchange coils made of quality copper tubes,efficient hyperbolic aluminum shutter fins, precise mechanic tube expansion.
(4)Easy installation and operation
*With thickness body can be installed in a limit ceiling;
*No need air duct,save installation cost,
*Remote controller or optional wire controller.
(5)Ingenious design
*With high head lift drained water pump;
*With inside float switch to prevent leaking;
*Fresh air can be inputed from outside is optional;
*4 pipe system and electrical heater is optional;
*Installed water valve is optional;
*Negative ion generator is optional;
*Finger guard is optioanl to prevent beening injury;
*Mod-Bus device is optional;
*Power loss memory function is optional;
*Unit external body insulation is optional;
*EC or DC motor is optional.
4. Eurostars Fan coil unit series
1 |
Ceiling concealed fan coil unit |
2 |
High ESP ducted fan coil unit |
3 |
Universal concealed fan coil unit |
4 |
Floor standing exposed fan coil unit |
5 |
Ultra thin exposed fan coil unit |
6 |
Ceiling exposed fan coil unit |
7 |
Ceiling cassette fan coil unit |
8 |
Ceiling exposed & floor standing fan coil unit |
9 |
Wall mounted fan coil unit |
5. Ceiling cassette fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Cassette Fan Coil Unit (4-way 2 pipe system) |
Model EST~ |
200C2 |
300C2 |
400C2 |
500C2 |
600C2 |
800C2 |
1000C2 |
1200C2 |
1400C2 |
1600C2 |
Power supply |
220V-1PH-50/60HZ |
Air flow
(m3/h) |
H |
360 |
540 |
720 |
900 |
1080 |
1430 |
1780 |
2130 |
2480 |
1830 |
M |
290 |
390 |
525 |
670 |
775 |
1050 |
1290 |
1560 |
1810 |
2050 |
L |
190 |
270 |
350 |
440 |
540 |
720 |
870 |
1060 |
1290 |
1370 |
Static pressure |
Pa |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
Cooling capacity |
TH |
H |
W |
2000 |
3000 |
3800 |
4900 |
5800 |
7500 |
9800 |
11000 |
12000 |
15000 |
BTU/h |
6826 |
10239 |
12969 |
16724 |
19795 |
25598 |
33447 |
37543 |
40956 |
51195 |
SH |
W |
1400 |
2200 |
2850 |
3500 |
4250 |
5500 |
7150 |
8250 |
9100 |
11175 |
BTU/h |
4778 |
7509 |
9727 |
11946 |
14505 |
18772 |
24403 |
28157 |
31058 |
38140 |
TH |
M |
W |
1700 |
2550 |
3250 |
4150 |
4950 |
6400 |
8350 |
9350 |
10200 |
12450 |
BTU/h |
5802 |
8703 |
11092 |
14164 |
16894 |
21843 |
28499 |
31912 |
34813 |
42492 |
SH |
W |
1150 |
1800 |
2350 |
2850 |
3500 |
4550 |
5950 |
6850 |
7650 |
9560 |
BTU/h |
3925 |
6143 |
8021 |
9727 |
11946 |
15529 |
20307 |
23379 |
26109 |
32628 |
TH |
L |
W |
1400 |
2050 |
2600 |
3400 |
4000 |
5200 |
6750 |
7600 |
8300 |
10300 |
BTU/h |
4778 |
6997 |
8874 |
11604 |
13652 |
17748 |
23038 |
25939 |
28328 |
35154 |
SH |
W |
950 |
1400 |
1850 |
2300 |
2800 |
3600 |
4700 |
5450 |
6000 |
8400 |
BTU/h |
3242 |
4778 |
6314 |
7850 |
9556 |
12287 |
16041 |
18601 |
20478 |
28669 |
Heating capacity |
H |
W |
3100 |
4700 |
5900 |
7600 |
9000 |
11600 |
15200 |
17100 |
18600 |
24000 |
BTU/h |
10580 |
16041 |
20137 |
25939 |
30717 |
39591 |
51878 |
58362 |
63482 |
81912 |
M |
W |
2650 |
4000 |
5000 |
6450 |
7650 |
9850 |
12900 |
14550 |
15800 |
19900 |
BTU/h |
9044 |
13652 |
17065 |
22014 |
26109 |
12900 |
44028 |
49659 |
53925 |
67919 |
L |
W |
2100 |
3150 |
3950 |
5100 |
6050 |
7750 |
10200 |
11450 |
12450 |
15200 |
BTU/h |
7167 |
10751 |
13481 |
17406 |
20649 |
26451 |
34813 |
39079 |
42492 |
51878 |
Cassette Fan Coil Unit(4-way 4 pipe system) |
|
Model EST~ |
200C4 |
300C4 |
400C4 |
500C4 |
600C4 |
800C4 |
1000C4 |
1200C4 |
1400C4 |
1600C4 |
Power supply |
220V-1PH-50/60HZ |
Air flow
(m3/h) |
H |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
2720 |
M |
280 |
380 |
515 |
660 |
765 |
1040 |
1280 |
1550 |
1800 |
2040 |
L |
180 |
260 |
340 |
430 |
530 |
710 |
860 |
1050 |
1280 |
1360 |
Sta.pressure |
|
Pa |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
Cooling capacity |
TH |
H |
W |
1950 |
2950 |
3700 |
4800 |
5700 |
7350 |
9600 |
10800 |
11750 |
13200 |
BTU/h |
6655 |
10068 |
12628 |
16382 |
19454 |
25086 |
32765 |
36860 |
40103 |
45052 |
SH |
W |
1350 |
2150 |
2800 |
3450 |
4150 |
5400 |
7000 |
8100 |
8900 |
10000 |
BTU/h |
4608 |
7338 |
9556 |
11775 |
14164 |
18430 |
23891 |
27645 |
30376 |
34130 |
TH |
M |
W |
1650 |
2500 |
3200 |
4050 |
4850 |
6250 |
8200 |
9150 |
10000 |
11000 |
BTU/h |
5631 |
8533 |
10922 |
13823 |
16553 |
21331 |
27987 |
31229 |
34130 |
37543 |
SH |
W |
1150 |
1750 |
2300 |
2800 |
3450 |
4450 |
5850 |
6700 |
7500 |
37532 |
BTU/h |
3925 |
5973 |
7850 |
9556 |
11775 |
15188 |
19966 |
22867 |
25598 |
128097 |
TH |
L |
W |
1350 |
2000 |
2550 |
3350 |
3900 |
5100 |
6600 |
7450 |
8150 |
9100 |
BTU/h |
4608 |
6826 |
8703 |
11434 |
13311 |
17406 |
22526 |
25427 |
27816 |
31058 |
SH |
W |
950 |
1350 |
1800 |
2250 |
2750 |
3550 |
4600 |
5350 |
5900 |
6600 |
BTU/h |
3242 |
4608 |
6143 |
7679 |
9386 |
12116 |
15700 |
18260 |
20137 |
22526 |
Heating capacity |
H |
W |
1950 |
3000 |
3750 |
4850 |
5750 |
7400 |
9700 |
10900 |
11850 |
13500 |
BTU/h |
6655 |
10239 |
12799 |
16553 |
19625 |
25256 |
33106 |
37202 |
40444 |
46076 |
M |
W |
1700 |
2550 |
3200 |
4100 |
4850 |
6250 |
8200 |
9250 |
10050 |
11200 |
BTU/h |
5802 |
8703 |
10922 |
13993 |
16553 |
21331 |
27987 |
31570 |
34301 |
38226 |
L |
W |
1350 |
2000 |
2500 |
3250 |
3850 |
4950 |
6500 |
7300 |
7950 |
8750 |
BTU/h |
4608 |
6826 |
8533 |
11092 |
13140 |
16894 |
22185 |
24915 |
27133 |
29864 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
6. Ceiling cassette fan coil pipe system
7. Our company certificates and fan coil production line
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
Every fan coil has strict production process, including assembly, testing, packing.
8. FAQ
Q: Can I have a sample for testing before ordering products?
A: Yes, you can. And you are warmly welcomed to visit our factory before PO.
Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
Q: How to properly install the fan coil unit?
A: We have very detailed user manual and installation instructions, also can be directly telephone or online video guidance.
9. Our service and Customer visit
Considerate after-sales service & product maintenance.You can contact us at any time.
Economical and energy-saving design scheme
Overseas engineer services
Integrated quality and profession R&D team
OEM/ODM available
10. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
11. Cassette fan coil installation instruction
12. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..