Basic Info.

Model NO.
EST30HC4
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Air-Conditioning (HVAC)System
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
ISO, CE
Condition
New
Base
C-Channel Hot DIP Base
Optional 1
VSD, VFD
Control
Option for PLC, Ddc
Ahu Panels
Painted Steel, Gi, Ss Panels
Filters
Pre-Filter, Bag Filter, HEPA Filter
PU Foam Insulation
43-48kg/M3
Ahu Construction
25mm/ 50mm/ 75mm Double Skin
Ahu Framework
Aluminum
Fan
Belt Drive Centrifugal Fan, Plug Fan, Ec Fan
Cooling/ Heating Coil 1
Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr
Cold Bridge Free Design
Yes
Side Sliding Filter with Tracks
Yes
Optional 3
Ep, Chemical Filter, Plasma Sterilizer, Ak
Cooling/ Heating Coil 2
Copper Tube with Copper Fins (Cu/Cu), Gi/SUS Frame
Optional 2
Heat Recovery Wheel
Transport Package
Standard Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8415830000
Production Capacity
2000pieces/Year

Product Description

1. Eurostars air handling unit and air handler features
1) Streamline design, durable and beautiful appearance.
2) With integrate and special triangle water distribution structure, make the water distribute evenly.
3) Using highly efficient cooling pads with large evaporation capacity, good cooling efficiency and easy to clean.
4) Using intelligent LCD control, easy to operate and understand(optional).
5) Specially-designed axial fan, with large air flow ,low noise, energy-saving and large application.
6) Two-way ventilation function: achieve two-way air exchange indoor and outdoor, take the outdoor fresh air into the room. While indoor polluted air let out the room, create new healthy green air-conditioning for you.
7) Efficient heat recovery efficiency of energy recovery can be built to complete the whole heat or sensible heat recovery, heat recovery efficiency of the whole is greater than 70%, significantly greater than 63% heat recovery efficiency, reduce energy consumption required for processing of fresh air for efficient energy saving.
8) Low Noise Design: built-in special low-noise air-conditioning fan, the machine housing wall covered with new sound-absorbing material, all quiet design, human embodiment of air conditioning super design.
9) Air filtration and purification functions: a coarse, medium and high efficiency filters available to prevent dust and other pollutants into the room, creating a clean environment


2.Eurostars Air handler,air handling unit, ahu application
An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system. An air handler is usually a large metal box containing a blower, heating or cooling elements, filter racks or chambers, sound attenuators, and dampers. Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU. Sometimes AHUs discharge (supply) and admit (return) air directly to and from the space served without ductwork


3.Air handler technical data, Assembly drawing diagram and photo
Horizontal Air Handling Unit(Return Air Condition-4 Rows)
Model Air Flow   Total
Pressure
Power Input Return Air
Cooling Capacity Heating Capacity Water Flow  Water Resistance Water inlet/outlet pipe Diameter
*1000CMH Pa kW kW L/min kPa DN
EST10HC4 10 350 2.2 60.4 84 172.8 18.6 50
EST12HC4 12 400 3 73 101.7 209.4 21.6 50
EST15HC4 15 400 4 98.6 138.9 282.6 22.5 65
EST18HC4 18 400 5.5 118.3 165 339.6 24.5 65
EST20HC4 20 400 5.5 139.5 194.4 400.2 30.4 65
EST23HC4 23 400 5.5 157.9 219.9 456 25.5 65
EST25HC4 25 400 7.5 169.5 236.3 486.6 37.2 80
EST28HC4 28 500 2*4 186.3 259.7 534 26.5 80
EST30HC4 30 500 2*5.5 199.3 277.9 571.8 22.5 2*65
EST35HC4 35 500 2*5.5 235.7 328.3 676.2 29.4 2*65
EST40HC4 40 500 2*5.5 271.2 378 778.2 34.3 2*65
EST45HC4 45 500 2*7.5 286.2 398.8 821.4 40.2 2*65
EST50HC4 50 600 2*11 322.7 449.8 925.8 51.9 2*80
NOTE:
  1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC;
  2. Return air: Heaing: Air in 15ºC DB,Hot water in: 60ºC.
Marine/Seawater Combined Air Handling Unit
4. Eurostars air handling unit , air handler range or series
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modular Modulus Air Handling Unit-multi-function air handling unit
Marine/Seawater Combined Air Handling Unit
5. Components-air handling unit or air handler

Panel and Insulation
•Galvanized steel(GI) and stainless steel(SS) available
•Double skin, 25~50mm PU insulation
Marine/Seawater Combined Air Handling Unit
Frame
•Penta-post extra heavy gauge aluminum profiles and strong fiber-reinforced PE corner connection forming the structural  frame
• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation
• Thermal bridge free design, the profiles filled with polyurethane foam for insulation
• Anodizing surface treatment for profiles, corrosion-resistant
• Stainless steel frame available
Marine/Seawater Combined Air Handling Unit
Famous Brand Blower and Motor
•Energy saving Fan with low speed and low noise
•Type: Direct driven / Belt driven
            Forward curve and backward curve
            Centrifugal fan and EC plug fan
•Brand: Nicotra, Kruger, Deton, Yilida available
•Low noise long life Motor
•Brand: Siemens, ABB and Teco available
Marine/Seawater Combined Air Handling Unit
Vibration Eliminator
• To reduce the transmission of vibration and noise, fan and motor are installed on an independent complete base frame
• The complete base frame is isolated by deflection type spring isolators
• This unique structure not only reduce the vibration and noise, but also protect fan and motor during transportation


Cooling/ Heating Coil
•Large coil face area with low air speed
•Various anti-corossion coating for option, Electrophoresis and Heresite coating available
•Type: Copper tube with Aluminium fins (Cu/Al), GI/SUS frame
            Copper tube with Copper fins (Cu/Cu), GI/SUS frame
•Rows: 4R/6R(can be 2R+4R design)/8R (can be 4R+4R design)
Copper Tube Protection
•Every mounting hole filled up glass cement to prevent copper tube damage during transportation and operation
Marine/Seawater Combined Air Handling Unit
High efficiency filter
Air filtration is almost always present in order to provide clean dust-free air to the building occupants. It may be via simple low-MERV pleated media, HEPA, electrostatic, or a combination of techniques. Gas-phase and ultraviolet air treatments may be employed as well.

Filtration is typically placed first in the AHU in order to keep all the downstream components clean. Depending upon the grade of filtration required, typically filters will be arranged in two (or more) successive banks with a coarse-grade panel filter provided in front of a fine-grade bag filter, or other "final" filtration medium. The panel filter is cheaper to replace and maintain, and thus protects the more expensive bag filters.

The life of a filter may be assessed by monitoring the pressure drop through the filter medium at design air volume flow rate. This may be done by means of a visual display using a pressure gauge, or by a pressure switch linked to an alarm point on the building control system. Failure to replace a filter may eventually lead to its collapse, as the forces exerted upon it by the fan overcome its inherent strength, resulting in collapse and thus contamination of the air handler and downstream ductwork.

Marine/Seawater Combined Air Handling Unit
Stainless Steel Drain Pan
• Slop type design, no drain water carryover and keep the pan dry
• Avoid the micro-organisms growth inside the drain pan
Antimicrobial Drain Pan is offered as option
• SteriTouch technology Drip Pan Coating
• Antimicrobial surface
• Good exterior durability and corrosion resistance
• Excellent adhesion
• Non-toxic, comply with BS476 part 7
Marine/Seawater Combined Air Handling Unit
Electrical control cabinet(optioanl)
•According to the requirements and functions of the unit to design the control console or cabinet
•Auto control each section of the unit to make sure the temperature, humidity and cleaness 
•High quality and international brand electrical elements
•DDC and PLC available

6.Why choose us?
Eurostars offers One Stop Solutions for:
•Pharmaceuticals industry
•Electronics industry
•Automobile industry
•Printing and food industry
•Commercial building
•VOC treatment and environment protection
•Indoor air quality
•Marine ventilation
Marine/Seawater Combined Air Handling Unit
7.FAQ
Q:What are the differences between an air conditioner and an air handler?
Air handlers are an important part of your overall HVAC system, but they are not the complete air conditioning system.

An air handler is responsible for housing the equipment necessary to move air through your home or business. In most cases, it is located inside and operates both the heating and cooling systems. Air handlers look like a furnace, and are sometimes even mistaken for one. Air handlers can be made to work with a heat pump or air conditioner. It includes the indoor coil, which depending on the setting your system is running on, is used for both heating and cooling.

Air conditioning units include the condenser and are usually kept outside of your home or business.  Air conditioners actively pull heat out of the building through a variety of components configured together, and then this hot air is redirected outside. Throughout the process, air moves through the system via return ducts and over a refrigerant coil. Instead of adding cold air to the room, which is what it feels like, the system is actually just pulling hot air out and then recirculating the same air (without the heat) back into the building. 


8.Customer visit us
Marine/Seawater Combined Air Handling Unit
9.Air handling unit,air handler delivery or container loading
Marine/Seawater Combined Air Handling Unit
10.Installation instruction or installation photo, project photos
Marine/Seawater Combined Air Handling Unit

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier