Commercial Type, Industrial Type, Air Handling Unit, Ahu
Contact Supplier
Product Attributes
- Customization
- Available
- Type
- Air Handling Unit
- Air Tube Material
- Galvanized Sheet
- Model NO.
- EST28HC4
- Corrosion Durability
- Higher
- Operating Voltage
- 380/400 VAC
- Noise Level
- Low
- Application Fields
- Air-Conditioning (HVAC)System
- Mounting
- Ceiling Mount
- Lifetime
- >20 years
- Certification
- ISO, CE
- Condition
- New
- Base
- C-Channel Hot DIP Base
- Ahu Panels
- Painted Steel, Gi, Ss Panels
- Filters
- Pre-Filter, Bag Filter, HEPA Filter
- PU Foam Insulation
- 43-48kg/M3
- Ahu Construction
- 25mm/ 50mm/ 75mm Double Skin
- Ahu Framework
- Aluminum
- Fan
- Belt Drive Centrifugal Fan, Plug Fan, Ec Fan
- Optional 1
- VSD, VFD
- Control
- Option for PLC, Ddc
- Cooling/ Heating Coil 1
- Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr
- Cold Bridge Free Design
- Yes
- Side Sliding Filter with Tracks
- Yes
- Optional 3
- Ep, Chemical Filter, Plasma Sterilizer, Ak
- Cooling/ Heating Coil 2
- Copper Tube with Copper Fins (Cu/Cu), Gi/SUS Frame
- Optional 2
- Heat Recovery Wheel
- Transport Package
- Standard Package
- Specification
- CE
- Trademark
- ESACIR
- Origin
- Guangdong, China
- HS Code
- 8415830000
- Production Capacity
- 2000pieces/Year
Product Images of Commercial Type, Industrial Type, Air Handling Unit, Ahu
Find Similar Products
Product Description
1) Streamline design, durable and beautiful appearance.
2) With integrate and special triangle water distribution structure, make the water distribute evenly.
3) Using highly efficient cooling pads with large evaporation capacity, good cooling efficiency and easy to clean.
4) Using intelligent LCD control, easy to operate and understand(optional).
5) Specially-designed axial fan, with large air flow ,low noise, energy-saving and large application.
6) Two-way ventilation function: achieve two-way air exchange indoor and outdoor, take the outdoor fresh air into the room. While indoor polluted air let out the room, create new healthy green air-conditioning for you.
7) Efficient heat recovery efficiency of energy recovery can be built to complete the whole heat or sensible heat recovery, heat recovery efficiency of the whole is greater than 70%, significantly greater than 63% heat recovery efficiency, reduce energy consumption required for processing of fresh air for efficient energy saving.
8) Low Noise Design: built-in special low-noise air-conditioning fan, the machine housing wall covered with new sound-absorbing material, all quiet design, human embodiment of air conditioning super design.
9) Air filtration and purification functions: a coarse, medium and high efficiency filters available to prevent dust and other pollutants into the room, creating a clean environment
2.Eurostars Air handler,air handling unit, ahu application
EUROSTARS air handling unit can cool, dry, heat, humidify, filter and purify air with silencer function. It can be widely applied in the places where the air needs to be conditioned in a centralized way, such as shopping malls, hotels, office buildings and stadiums, as well as other purification air-conditioning places, such as hospital operating rooms, pharmaceutical, tobacco, food, precision instruments manufacturing rooms.
3.Air handler technical data, Assembly drawing diagram and photo
| Horizontal Air Handling Unit(Return Air Condition-4 Rows) | ||||||||
| Model | Air Flow | Total Pressure |
Power Input | Return Air | ||||
| Cooling Capacity | Heating Capacity | Water Flow | Water Resistance | Water inlet/outlet pipe Diameter | ||||
| *1000CMH | Pa | kW | kW | L/min | kPa | DN | ||
| EST10HC4 | 10 | 350 | 2.2 | 60.4 | 84 | 172.8 | 18.6 | 50 |
| EST12HC4 | 12 | 400 | 3 | 73 | 101.7 | 209.4 | 21.6 | 50 |
| EST15HC4 | 15 | 400 | 4 | 98.6 | 138.9 | 282.6 | 22.5 | 65 |
| EST18HC4 | 18 | 400 | 5.5 | 118.3 | 165 | 339.6 | 24.5 | 65 |
| EST20HC4 | 20 | 400 | 5.5 | 139.5 | 194.4 | 400.2 | 30.4 | 65 |
| EST23HC4 | 23 | 400 | 5.5 | 157.9 | 219.9 | 456 | 25.5 | 65 |
| EST25HC4 | 25 | 400 | 7.5 | 169.5 | 236.3 | 486.6 | 37.2 | 80 |
| EST28HC4 | 28 | 500 | 2*4 | 186.3 | 259.7 | 534 | 26.5 | 80 |
| EST30HC4 | 30 | 500 | 2*5.5 | 199.3 | 277.9 | 571.8 | 22.5 | 2*65 |
| EST35HC4 | 35 | 500 | 2*5.5 | 235.7 | 328.3 | 676.2 | 29.4 | 2*65 |
| EST40HC4 | 40 | 500 | 2*5.5 | 271.2 | 378 | 778.2 | 34.3 | 2*65 |
| EST45HC4 | 45 | 500 | 2*7.5 | 286.2 | 398.8 | 821.4 | 40.2 | 2*65 |
| EST50HC4 | 50 | 600 | 2*11 | 322.7 | 449.8 | 925.8 | 51.9 | 2*80 |
| NOTE: | ||||||||
| 1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC; | ||||||||
| 2. Return air: Heaing: Air in 15ºC DB,Hot water in: 60ºC. | ||||||||

4. Eurostars air handling unit , air handler range or series
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modular Modulus Air Handling Unit-multi-function air handling unit

5. Components-air handling unit or air handler
Panel and Insulation
•Galvanized steel(GI) and stainless steel(SS) available
•Double skin, 25~50mm PU insulation

Frame
•Penta-post extra heavy gauge aluminum profiles and strong fiber-reinforced PE corner connection forming the structural frame
• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation
• Thermal bridge free design, the profiles filled with polyurethane foam for insulation
• Anodizing surface treatment for profiles, corrosion-resistant
• Stainless steel frame available

Famous Brand Blower and Motor
•Energy saving Fan with low speed and low noise
•Type: Direct driven / Belt driven
Forward curve and backward curve
Centrifugal fan and EC plug fan
•Brand: Nicotra, Kruger, Deton, Yilida available
•Low noise long life Motor
•Brand: Siemens, ABB and Teco available

Vibration Eliminator
• To reduce the transmission of vibration and noise, fan and motor are installed on an independent complete base frame
• The complete base frame is isolated by deflection type spring isolators
• This unique structure not only reduce the vibration and noise, but also protect fan and motor during transportation
Cooling/ Heating Coil
•Large coil face area with low air speed
•Various anti-corossion coating for option, Electrophoresis and Heresite coating available
•Type: Copper tube with Aluminium fins (Cu/Al), GI/SUS frame
Copper tube with Copper fins (Cu/Cu), GI/SUS frame
•Rows: 4R/6R(can be 2R+4R design)/8R (can be 4R+4R design)
Copper Tube Protection
•Every mounting hole filled up glass cement to prevent copper tube damage during transportation and operation

High efficiency filter
Air filtration is almost always present in order to provide clean dust-free air to the building occupants. It may be via simple low-MERV pleated media, HEPA, electrostatic, or a combination of techniques. Gas-phase and ultraviolet air treatments may be employed as well.
Filtration is typically placed first in the AHU in order to keep all the downstream components clean. Depending upon the grade of filtration required, typically filters will be arranged in two (or more) successive banks with a coarse-grade panel filter provided in front of a fine-grade bag filter, or other "final" filtration medium. The panel filter is cheaper to replace and maintain, and thus protects the more expensive bag filters.
The life of a filter may be assessed by monitoring the pressure drop through the filter medium at design air volume flow rate. This may be done by means of a visual display using a pressure gauge, or by a pressure switch linked to an alarm point on the building control system. Failure to replace a filter may eventually lead to its collapse, as the forces exerted upon it by the fan overcome its inherent strength, resulting in collapse and thus contamination of the air handler and downstream ductwork.

Stainless Steel Drain Pan
• Slop type design, no drain water carryover and keep the pan dry
• Avoid the micro-organisms growth inside the drain pan
Antimicrobial Drain Pan is offered as option
• SteriTouch technology Drip Pan Coating
• Antimicrobial surface
• Good exterior durability and corrosion resistance
• Excellent adhesion
• Non-toxic, comply with BS476 part 7

Electrical control cabinet(optioanl)
•According to the requirements and functions of the unit to design the control console or cabinet
•Auto control each section of the unit to make sure the temperature, humidity and cleaness
•High quality and international brand electrical elements
•DDC and PLC available
6.Why choose us?
Eurostars offers One Stop Solutions for:
•Pharmaceuticals industry
•Electronics industry
•Automobile industry
•Printing and food industry
•Commercial building
•VOC treatment and environment protection
•Indoor air quality
•Marine ventilation

7.FAQ
Q:What are the differences between an air conditioner and an air handler?
Air handlers are an important part of your overall HVAC system, but they are not the complete air conditioning system.
An air handler is responsible for housing the equipment necessary to move air through your home or business. In most cases, it is located inside and operates both the heating and cooling systems. Air handlers look like a furnace, and are sometimes even mistaken for one. Air handlers can be made to work with a heat pump or air conditioner. It includes the indoor coil, which depending on the setting your system is running on, is used for both heating and cooling.
Air conditioning units include the condenser and are usually kept outside of your home or business. Air conditioners actively pull heat out of the building through a variety of components configured together, and then this hot air is redirected outside. Throughout the process, air moves through the system via return ducts and over a refrigerant coil. Instead of adding cold air to the room, which is what it feels like, the system is actually just pulling hot air out and then recirculating the same air (without the heat) back into the building.
8.Customer visit us

9.Air handling unit,air handler delivery or container loading

10.Installation instruction or installation photo, project photos
About the Supplier
This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASR232130". Items marked "" are certified.
Company Profile
We, EUROSTARS, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
The current product lines range from central Heating Ventilation Air Conditioning System to Industrial Refrigeration and Cooling System; Main products including as below:
- Commercial Water Cooled Chiller (with heat recovery)
- Commercial Air Cooled Chiller (with heat recovery)
- Industrial Chillers including Glycol Chillers (with heat recovery)
- Water(Ground)Source Heat Pump
- Air Source Heat Pump
- Unitary Air Conditioner, including ducted split air conditioner, rooftop air conditioner
- Fan Coil Unit and Air Handlers
-Cold Room Condensing Unit and Cold Room Evaporators
- Heat Exchangers, including tube shell heat exchanger, finned tube heat exchanger
We strive to become the best Reliable Manufacturer and Supplier of High Quality Heating Ventilation Air Conditioning and Industrial Refrigeration, offer wide range of products and competitive price for meeting the customers' real demand.
Perfect quality depends on the professional technical support team and standardized operation flow. EUROSTARS owns advanced production and testing equipments, including assembly production lines for large and small units respectively, heat exchanger pipeline, CNC processing center, CNC punching and bending machine, pipe expanding machine, automatic welder, large national-level testing center for water cooled and air cooled chiller, national-level testing center for water (heat pump) unit, etc., thus ensuring product quality and services.
EUROSTARS Spirit: Openness Sincerity the Base, Professional Supreme
EUROSTARS Tenet: Environmental Friendly, Energy Saving
EUROSTARS Service Philosophy: Customer-focused to Win-Win Platform
EUROSTARS Quality Policy: Product Quality for Fundamental
About Our Factory & Business Background
-
Business Type
- Manufacturer/Factory & Trading Company
- Address
- The Third Industrial Area, No. 150, Sha Song Road, Bao an District, Shenzhen, Guangdong, China
-
Plant Area
- 4200 square meters
-
Number of Employees
- 45
-
Registered Capital
- 500,000 RMB
-
Terms of Payment
- LC, T/T
-
International Commercial Terms(Incoterms)
- FOB, CIF, CFR
-
Average Lead Time
-
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays -
Nearest Port
- Shenzhen Port
Our Production Capability & Technical Expertise
-
Main Products
- Water Chiller, Fan Coil, Package Air Conditioning, Refrigeration Condensing Unit-Evaporator
-
Production Machines
- Bending Facility, Fin Punching Facility, Laser Cutting Facility, Punching Facility, Tube Bending Facility
-
ODM Service Available
- Yes
-
OEM Service Available
- Yes
-
R&D Engineers
- 4 people
-
Own Brand
- Yes
Our Industry Experience & Global Business Record
-
Year of Establishment
- 2013-06-03
- Export Year
- 2013-06-11
-
Main Markets
- South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
-
Number of Foreign Trading Staff
- 3
-
Overseas Agent/Branch
- No
Our Certifications, Standards & Industry Recognition
-
Product Certification
- CE
Send your message to this supplier
People who viewed this also viewed
-
US$80.00-150.00 / Piece
-
US$150.00-290.00 / Piece
-
US$80.00-150.00 / Piece
-
US$300.00-20,000.00 / Piece
-
US$80.00-150.00 / Piece
-
US$80.00-150.00 / Piece
-
US$80.00-210.00 / Piece
-
US$60.00-180.00 / Piece
-
US$60.00-180.00 / Piece
-
US$60.00-400.00 / Piece
Find Similar Products By Category
- Supplier Homepage
- Products
- Air Handling Unit/Air Handler
- Commercial Type, Industrial Type, Air Handling Unit, Ahu
Related Categories
Hot Searches
- Air Cooler Factories
- Air Pump Factories
- Air Compressor Factories
- Air Cylinder Factories
- Air Handling Unit Prices
- Custom Air Handling Unit
- Ce Air Handling Unit
- Air Handling Unit Cost
- Air Handling Unit Component
- Air Handling Unit Bulkbuy