4.5kw Four Way Ceiling Cassette Fan Coil Unit with Drain Pump (EST500C2)

Product Details
Customization: Available
Type: Fan Coil Unit
Air Tube Material: Plastic Casing, Galvanized Sheet Unit Body
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
Find Similar Products

Basic Info.

Model NO.
EST500C2
Operating Voltage
110V/220~240V-50Hz/60Hz-1pH
Noise Level
Low
Application Fields
HVAC for Restaurant/School/Building/Hotel
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
CE
Condition
New
Color
White
Pipe System
Two Pipe and Four Pipe System
Air Outlet
1 Way or 4 Way or Multi Way
Water Inlet/Outlet Pipe Size
Zg 3/4"
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Trademark
Eurostars
Origin
Guangdong, Prc.
HS Code
84159010
Production Capacity
6000 PCS/Year

Product Description

4.5KW Four Way Ceiling Cassette Fan Coil Unit with Drain Pump(EST500C2)

1. Ceiling cassette fan coil unit features:
(1)Ultra-low noise; (2) High efficient and energy saving; (3) Strong air flow; (4) Easy installation and oeration; (5)Ingenious design.

In central air conditioner system, Eurostars ceiling cassette fan coil unit continuously exchanges the indoor air with cool & heat supplied by chiller system, in order to adjust the room temperature and humidity. Ceiling floor fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.

2. Ceiling cassette floor fan coil unit nomenclature

ES  T   600    C2   K4   Q    0    A   O
1    2      3       4     5     6    7    8    9
1: ES Eurostars
2 :T Terminal series
3 :600 Rated air flow: CFM
4 :C2 Cassette type and the number of tube system
5 :K4 Air outlet: K4-Four way; K1-One way; K2-Two way; K-Multi way                                    

6 :Q Drainage way:
     Q-Forced drainage, electronic control;   V-Forced drainage, electronic control, built-in water valve
     S-Natural drainage, no control;                 H-Natural drainage, electronic control
7: 0 Inbuilt electrical heating: 0-None;  1-Electrical heating power 1.0KW (so on and so forth)
8: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ
9 :O Sales region: O-Other regions;  C-Mainland China


3.Ceiling cassette fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com

Cassette Fan Coil Unit (4-way  2 pipe system)
Model   EST~ 200C2 300C2 400C2 500C2 600C2 800C2 1000C2 1200C2 1400C2
Power supply 220V,50Hz,1Ph
Air flow
 (m3/h)
H 340 510 680 850 1020 1360 1700 2040 2380
M 280 380 515 660 765 1040 1280 1550 1800
L 180 260 340 430 530 710 860 1050 1280
Static pressure Pa 0 0 0 0 0 0 0 0 0
Cooling capacity TH H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
BTU/h 6142 9212 12283 15354 18425 24566 30708 36850 42991
SH W 1311 1971 2700 3184 4196 5362 6707 8072 9070
BTU/h 4473 6725 9212 10864 14317 18295 22884 27542 30947
TH M W 1500 2460 3000 3715 4423 6435 7848 9296 10500
BTU/h 5118 8394 10236 12676 15091 21956 26777 31718 35826
SH W 994 1555 1995 2426 3041 4236 5393 6603 7190
BTU/h 3392 5306 6807 8278 10376 14453 18401 22529 24532
TH L W 1391 2057 2479 2921 3793 5604 7223 8534 8900
BTU/h 4746 7018 8458 9966 12945 19121 24645 29118 30367
SH W 823 1200 1530 1826 2373 3284 4416 5248 5500
BTU/h 2808 4094 5220 6230 8097 11205 15067 17906 18766
Heating capacity H W 2700 4050 5400 6750 8100 10800 13500 16200 18900
BTU/h 9215  13823  18430  23038  27645  36860  46076  55291  64506 
M W 1949 2770 3938 4902 5694 7924 10473 12997 13900
BTU/h 6652  9454  13440  16731  19434  27045  35744  44359  47441 
L W 1297 1774 2779 3505 3876 5421 6992 8645 9700
BTU/h 4427  6055  9485  11963  13229  18502  23864  29505  33106 
 Noise  H dB(A) 37 39 41 43 45 46 48 50 51
Power input H W 37 52 62 76 96 134 152 189 228
Water flow  H m3/h 0.31  0.46  0.62  0.77  0.93  1.23  1.54  1.85  2.16 
 Water resistance  kPa 11.8 11.8 22.4 27 29.6 29.6 35.4 35.4 40
Pipe  Inlet water pipe ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
Outlet water pipe ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
Coil type  Hydrophilic aluminum fin arounds high efficient copper pipe 
Working pressure MPa 1.6
Condensation water pipe mm ¢26 ¢26 ¢26 ¢26 ¢26 ¢26 ¢26 ¢26 ¢26
Dimension   Natural Drainage  L×W×H     mm 590*590*420 752*752*443 822*822*405 822*822*443
Forced Drainage 590*590*270 752*752*293 822*822*260 822*822*293
Panel 650*650*45 850*850*45 950*950*45
N.W.   Natural Drainage  kg 19 19 20 23 23 25 28 28 29
Forced Drainage  19 19 20 26 26 28 31 31 32
Panel 2.2 4.5 6

Cassette Fan Coil Unit(4-way  4 pipe system)
Model   EST~ 200C4 300C4 400C4 500C4 600C4 800C4 1000C4 1200C4 1400C4
Power supply 220V,50Hz,1Ph
Air flow
 (m3/h)
H 340 510 680 850 1020 1360 1700 2040 2380
M 280 380 515 660 765 1040 1280 1550 1800
L 180 260 340 430 530 710 860 1050 1280
Static pressure
Pa 0 0 0 0 0 0 0 0 0
Cooling capacity TH H W 1350 2030 2700 3380 4050 5400 6750 8100 9450
BTU/h 4606 6926 9212 11533 13819 18425 23031 27637 32243
SH W 1010 1520 2080 2450 3230 4130 5160 6220 6989
BTU/h 3446 5186 7097 8359 11021 14092 17606 21223 23846
TH M W 1130 1850 2250 2790 3320 4830 5890 6970 7873
BTU/h 3856 6312 7677 9519 11328 16480 20097 23782 26863
SH W 770 1200 1540 1870 2340 3260 4150 5080 5532
BTU/h 2627 4094 5254 6380 7984 11123 14160 17333 18875
TH L W 1040 1540 1860 2190 2840 4200 5420 6400 6674
BTU/h 3548 5254 6346 7472 9690 14330 18493 21837 22772
SH W 630 920 1180 1410 1830 2530 3400 4040 4234
BTU/h 2150 3139 4026 4811 6244 8632 11601 13784 14446
Heating capacity H W 1080 1620 2160 2700 3240 4320 5400 6480 7560
BTU/h 3686  5529  7372  9215  11058  14744  18430  22116  25802 
M W 780 1108 1575 1961 2278 3170 4189 5199 5560
BTU/h 2662  3782  5375  6693  7775  10819  14297  17744  18976 
L W 519 710 1112 1402 1550 2168 2797 3458 3880
BTU/h 1771  2423  3795  4785  5290  7399  9546  11802  13242 
Noise H dB(A) 37 39 41 43 45 46 48 50 51
Power input H W 37 52 62 76 96 134 152 189 228
Water flow volume Cooling Tube H m3/h 0.23  0.35  0.46  0.58  0.69  0.93  1.16  1.39  1.60 
Heating Tube 0.09  0.14  0.19  0.23  0.28  0.37  0.46  0.56  0.70 
Water resistance  Cooling H kPa 8.26 8.26 15.68 18.9 20.72 20.72 24.78 24.78 40
Heating 3.54 3.54 6.72 8.1 8.88 8.88 10.62 10.62 16
Inlet water pipe Cooling tube/
Heating tube
ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
Outlet water pipe ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4" ZG3/4"
Coil type  Hydrophilic aluminum fin arounds high efficient copper pipe 
Working pressure MPa 1.6
Condensation water pipe mm ¢26 ¢26 ¢26 ¢26 ¢26 ¢26 ¢26 ¢26 ¢26
Dimension   Natural Drainage unit L×W×H     mm 590*590*420 752*752*443 822*822*405 822*822*443
Forced Drainage unit 590*590*270 752*752*293 822*822*260 822*822*293
Panel 650*650*45 850*850*45 950*950*45
N.W.   Natural Drainage unit kg 19 19 20 23 23 25 28 28 29
Forced Drainage unit 19 19 20 26 26 28 31 31 32
Panel 2.2 4.5 6

Note:
(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)Heating: Inlet air temperature DB 21°C, heating water inlet temperature  60°C (tested by the same water flow with cooling condition).
(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.
(4)Rated air flow is tested in standard air condition with DB 20ºC.
(5)Specifications are subject to product improvement and change without notice.

4. Eurostars Ceiling cassette fan coil unit photos viewing
4.5kw Four Way Ceiling Cassette Fan Coil Unit with Drain Pump (EST500C2)
4. Eurostars Ceiling cassette fan coil unit dimension 
4.5kw Four Way Ceiling Cassette Fan Coil Unit with Drain Pump (EST500C2)
5.Ceiling cassette fan coil unit installation illustration

4.5kw Four Way Ceiling Cassette Fan Coil Unit with Drain Pump (EST500C2)
6. Eurostars fan coil unit series
((1)Wall mounted split fan coil unit
(2)Ceiling floor fan coil unit
(3)Horizontal concealed ceiling duct fan coil unit
(4)Horizontal exposed fan coil unit
(5)Ceiling cassette fan coil unit
(6)Vertical exposed fan coil unit
(7)Vertical concealed fan coil unit

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now