• Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle
  • Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle
  • Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle
  • Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle
  • Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle
  • Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle

Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 220~460V-50Hz/60Hz-3pH
Compressor Number: 1, 2, 4
Noise Level: Low
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ESSA Series
Application Fields
Pharmaceutical
Application Machine
Reaction Kettle
Certification
CE
Condition
New
Cabinet
PU Coated for Anti-Corrosion
Expansion Valve
Danfoss, Emerson
Condenser
Aluminum Finned Copper Tube
Evaporator
Plate, Shell Tube, Coil in Tank
Refrigerant
R407c, R404A
Compressor
Copeland
Controller
Microcomputer Control Punp
Color
Blue White
Tank
Stainless Steel, Unpressurized
Water Pump
Centrifugal Cnp
Solenoid Valve
Optional Castel, Hongsen
Fan
Axial
Service
OEM, ODM
Transport Package
Wooden Case
Specification
Chilled liquid outlet temp.: 0, -5, -10C
Trademark
ESACIR
Origin
Shenzhen
HS Code
8418692090
Production Capacity
3000 Units Per Year

Product Description

Air Cooled Glycol Chiller Pharmaceutical Water Chiller For Reaction Kettle 

1. Air cooled industrial glycol chiller applications

Glycol chillers are commonly used for cooling fermentation tanks, brine tanks, and wort coolers in the brewing industry. Glycol chillers are used to provide reliable temperature control for fermentation and storage temperatures. Glycol chillers come as high, medium, or low temperature chillers, applications in the following fields:
(1)Breweries
(2)Wineries
(3)Distilleries
(4)Cideries
(5)Kombucha
(6)Cold brew
(7)Medical
(8)Jacketed vessels

2. Eurostars air cooled glycol chiller main components
(1)Hermetic scroll compressors-Copeland, Danfoss
(2)Stainless steel centrifugal pump
(3)Non ferrous water piping
(4)Stainless steel chilled water insulated tank
(5)Stainless steel evaporator (housed in tank); Plate and shell tube type is optional
(6)Electronic temperature controller with full feature controls
(7)Attractive and durable steel cabinet (SS casing is optional)
(8)Designed for ease of accessibility to components
(9)Low ambient start-up package
(10)Split system (remote condenser) also available

Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle

3. Air cooled glycol chiller main features
(1)Widely apply small model in industrial refrigeration, such as injection molding industry, plastic extruder machine etc.
(2)Cooling Capacity: 1Ton~20Tons.
(3)Chilled water temperature: 5~25ºC 
(4)Refrigerant is R407C, R22, but R410A, R134A also available.
(5)Power Supply: 3PH-200V~415V-50/60HZ.
(6)Built-in stainless steel tank, famous brand high performance and water flow special pump. With fan motor, no need matching with cooling tower. It is easy to installation and operation.
(7)With international most advanced scroll type or piston compressor, bigger capacity chiller equipped two refrigeration circuits electrical, once one refrigeration circuit is malfunction, another refrigeration circuit can run as usual.
(8)Removable wheel on the bottom of fuselage, convenient and flexible.
(9)Streamlined appearance design, operation panel humanity design, convenient for operation.
(10)Microcomputer control, dedicated controller, and anti electromagnetic interference ability, our unit have high ability to bear cold and heat, strong control logic, rapid response, accurate action, compared with the traditional control mode, they are obviously superiority.
(11)Components and refrigeration system are all famous world brand original device

4. Eurostars air cooled industrial chiller protection devices
Motor overload protection Compressor motor overheat protection
Phase protection Discharge temperature overhigh protection
High&low pressure protection Returning water overheat protection
Low water flow/level protection Anti-freezing protection

5. Eurostars air cooled glycol chiller brief technical data 
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Air Cooled Chiller Unit(R404A,-10ºC)
Model      ESSA- 03ISKTY 05ISKTY 08ISKTY 10ISKTY 12ISKTY 15ISKTY
Rated Cooling Capacity KW 3.78  6.48  9.85  13.35  16.15  18.90 
USRT 1.08  1.84  2.80  3.80  4.59  5.38 
×1000 kcal/h 3.25  5.57  8.47  11.48  13.89  16.25 
Air Cooled Chiller Unit(R404A,-10ºC)
Model      ESSA- 20IDKTY 25IDKTY 30IDKTY 40IQKTY 50IQKTY 60IQKTY
Rated Cooling Capacity KW 26.70  32.3 37.8 53.4 64.6 75.6
USRT 7.59  9.19  10.75  15.19  18.37  21.50 
×1000 kcal/h 22.96  27.78  32.51  45.92  55.56  65.02 
Remarks:
(1) Rated Cooling Capacity Based on:DB Temperature 35ºC/WB Temperature 24ºC.
(2)Chilled glycol-water liquid in/outlet temp. -5ºC/-10ºC
(3)Chilled glycol-waterl iquid range: -10~0ºC; Ambient Temperature: 5ºC~43ºC.

6.Factory testing of Eurostars every chiller unit
(1)Pressurization and helium leak detection of refrigeration circuit
(2)Pressurization and leak testing of fluid circuit
(3)Chiller performance and power consumption at full load
(4)Proper operation of all controls, safety devices, and alarms
(5)Electrical tests according to standards 
Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle
 
7. What concentration of glycol is needed for freeze protection?
Glycol must be used in applications where the chiller is installed outdoors or when fluid temperatures below freezing are required. The freezing point of the water-glycol solution depends on the type and concentration of glycol, and whether or not the glycol contains inhibitors for corrosion protection. The table below provides a rough guide of the ethylene glycol concentration required for various ambient or operating temperatures. Choose a glycol concentration that results in a freezing point of several degrees below the lowest anticipated ambient or operating temperature.
Temperature (°C) 0 -5 -10 -15 -35
Temperature (°F) 32 23 14 5 -31
Ethylene glycol (% by volume) 20 30 30 40 55

8. FAQ about glycol for industrial chiller
Glycol is a very important element in any cooling system. Despite its ubiquity and its importance, most customers don't fully understand all that it does. In an effort to clear up some of the confusion about glycol, here are our answers to the most commonly asked questions.

Q: What is Glycol?
A: Glycol is a water-miscible organic compound in the alcohol family. It is commonly used for cooling in industrial and mechanical applications. Glycol is sometimes called antifreeze or a coolant. Though it acts similarly to a refrigerant, and someone may refer to glycol as a refrigerant, this statement is incorrect. Glycol cools solely through heat transfer in an exchanger; whereas, refrigerant uses an evaporation-condensation cycle to remove heat.

Q: What does glycol do in a processing cooling system?
A: The most important role glycol plays in a process cooling system is to adjust the temperature range of the system. Without any glycol in the system, the water will freeze at the normal 32°F (0°C). In this case, the system ambient temperature can never go below this temperature. However, many systems need temperature flexibility as pipes travel outside and into unheated areas. Adding glycol to the water lowers the freezing point. The percent of glycol determines what the new freezing point will be.

A lower freezing point means process fluid can be kept at colder temperatures. A greater difference between medium temperatures allows for a faster heat transfer process. Heat always travels in the direction of higher temperature to lower temperature. When a coolant with a colder temperature is used, more of the energy can be transferred from the other fluid or process to the coolant.

Q: What are the benefits of using glycol in my system?
A: Glycol often contains corrosion inhibitors which can help to prolong the life of components. Its main function is to enable a cooling system to operate at temperatures below the freezing point of water. Certain systems may require this lowered cooling for optimum performance.

Q: How do I change the ratio of my glycol mixture?
A: If you have purchased a ratio that is higher than what your system needs, do not panic. You can still use this blend. However, you will need to perform onsite mixing. This process will involve adding water to the blend. Only use filtered, distilled or reverse-osmosis water. General tap water often has minerals such as calcium that can affect the chiller. After mixing and filling the system, any air pockets will need to be removed to prevent system frothing in the chiller.

Q: What type of piping should I use for my glycol mixture?
A: Copper or ABS piping remain industrial standards for system piping. PVC is also sometimes used. The most important thing to consider when setting up a new system, is that the piping is properly sized. An undersized pipe may accidentally increase the pressure and could risk the rest of the system. Whereas, an oversized pipe may lower overall efficiency. Glycol is not recommended with galvanized piping, as it may adversely react with Zinc.

Q: Will adding glycol change anything in my chiller setup?
A: Since many chillers are factory set for water only solutions, some minor adjustments may need to be made. Areas such as the evaporator, pump, and hot gas bypass valve may need adjustments. Glycol has a lower specific heat capacity and a lower heat transfer efficiency. These factors must be considering when designing for a particular system. A trained professional should be able to easily make the necessary changes. The addition of glycol also changes maintenance concerns, as the new element will need to be tested and maintained along with the mechanical elements of the machine.

Q: Should I use glycol in my system?
A: If your system or atmosphere have the potential to go below 32°F (0°C), then a glycol-water mixture should be used. A chiller's process fluid should never freeze, as this stops the chiller's ability to do work, and could even cause mechanical damage.

9. Eurostars Company Ceritifcate & Customer Visiting
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.

Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle


Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle
10. Our factory view

Modern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numerical control punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,. etc..
Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle
Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle

Chiller production at our previous location as below
Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle

11. Eurostars air cooled industrial chiller package and delivery

Our standard package is plastic film with plywood case for safe delivery and easy to load/unload.

Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle
Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle

12. Eurostars industrial chiller projects

We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..
Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle
Air Cooled Glycol Chiller Pharmaceutical Water Chiller for Reaction Kettle

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now