Hygienic Pharmaceutical Air Handling Unit Fan Coil Unit

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
Find Similar Products

Basic Info.

Model NO.
EST8CD4
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
HVAC
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
CE
Condition
New
Air Handling Unit
Bule/White Panel
Motor
Jiangsheng/Siemens
Fan
Deton/Nicotra
Panel
30mm or 50mm
Transport Package
Standard Package
Specification
CE
Trademark
Eurostars
Origin
Guangdong, Prc
HS Code
8415909000
Production Capacity
2000PCS/Year

Product Description

1.Selling Point-Eurostars chilled water fan coil-air handling unit
a)Low Noise
b)Efficient and Energy Saving
c)Easy Operation and Installation
d)Compact Exterior
e)High quality
f)Competitive price
 
2.Product series-Eurostars chilled water fan coil-air handling unit
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modulus Air Handling Unit-multi-function air handling unit
 
3.Unit specification-air handling unit
Following is only one part of our whole air handling unit specification,please ask Eurostars salesman for other detailed specification.
Heat exchanger:4Rows
Heat exchangers:6Rows
Heat exchangers:8Rows

Model Air Flow Volume Motor-internal Linked Motor-external Linked  Return Air Fresh Air
Rated Air Flow Air Flow Range Pressure Power 
Input
Pressure Power
 Input
Cooling 
Capacity
Heating 
Capacity
Water 
Flow
Water 
Resistance
Cooling 
Capacity
Heating 
Capacity
Water 
Flow
Water 
Resistance
×1000  CMH Pa kW Pa kW kW L/min kPa kW L/min kPa
EST2CD4 2 1.7~2.2 140 0.32 150 0.55 11.44 18.41 34.5 3 22.72 20.67 68.5 9.5
EST2.5CD4 2.5 2.2~2.7 245 0.45 180 0.55 12.7 20.44 38.3 3.7 27.89 25.37 84.1 10.7
EST3CD4 3 2.7~3.2 230 0.55 200 0.75 13.89 22.36 41.9 4.4 33.1 30.12 99.8 11.8
EST3.5CD4 3.5 3.2~3.7 245 0.75 200 1.1 17.24 27.75 52 5.2 39.5 35.94 119.1 13.6
EST4CD4 4 3.7~4.4 230 0.75 250 1.1 20.63 33.21 62.2 6.1 45.94 41.8 138.5 15.4
EST5CD4 5 4.4~5.4 290 1.5 250 1.5 25.74 41.44 77.6 7.6 56.48 51.39 170.3 19.6
EST6CD4 6 5.4~6.4 230 2*0.55 300 2.2 30.91 49.76 93.2 11 68.19 62.05 205.6 22.7
EST7CD4 7 6.4~7.4 245 2*0.75 300 2.2 36.08 58.08 108.8 14.8 79.87 72.68 240.8 30.3
EST8CD4 8 7.4~8.4 230 2*0.75 300 2.2 41.26 66.42 124.4 18.6 91.55 83.31 276 41
EST9CD4 9 8.4~9.2 360 2*1 350 3 46.37 74.65 139.8 20.6 102.99 93.72 310.5 45
EST10CD4 10 9.2~10.8 320 2*1.1 350 3 51.61 83.09 155.6 22.8 114.9 104.55 346.4 49
EST12CD4 12 10.8~13 310 2*1.5 350 2*2.2 62.12 100.01 187.3 28.3 140.04 127.43 422.2 60
EST15CD4 15 13~15.4 440 2*1.5 400 2*3.0 73.87 118.93 222.7 33.8 167.41 152.34 504.7 71

Model Air Flow Volume Motor-internal Linked Motor-external Linked  Return Air Fresh Air
Rated Air Flow Air Flow Range Pressure Power
 Input
Pressure Power
 Input
Cooling 
Capacity
Heating 
Capacity
Water 
Flow
Water 
Resistance
Cooling 
Capacity
Heating
 Capacity
Water
 Flow
Water 
Resistance
×1000  CMH Pa kW Pa kW kW L/min kPa kW L/min kPa
EST2CD6 2 1.7~2.2 100 0.32 150 0.55 15.42 24.82 46.5 3.8 31.57 28.72 95.2 13
EST2.5CD6 2.5 2.2~2.7 205 0.45 180 0.55 17.14 27.59 51.7 4.7 38.74 35.25 116.8 14.5
EST3CD6 3 2.7~3.2 190 0.55 200 0.75 18.74 30.17 56.5 5.6 46 41.86 138.7 16
EST3.5CD6 3.5 3.2~3.7 205 0.75 200 1.1 23.28 37.48 70.2 6.6 54.89 49.94 165.5 18.3
EST4CD6 4 3.7~4.4 190 0.75 250 1.1 27.83 44.8 83.9 7.7 63.85 58.1 192.5 20.6
EST5CD6 5 4.4~5.4 250 1.5 250 1.5 34.72 55.89 104.7 9.7 78.51 71.44 236.7 24.2
EST6CD6 6 5.4~6.4 190 2*0.55 300 2.2 41.72 67.16 125.8 14 94.76 86.23 285.7 30
EST7CD6 7 6.4~7.4 205 2*0.75 300 2.2 48.69 78.39 146.8 18.9 111.02 101.02 334.7 36.4
EST8CD6 8 7.4~8.4 190 2*0.75 300 2.2 55.69 89.66 167.9 23.7 127.24 115.78 383.6 48.6
EST9CD6 9 8.4~9.2 340 2*1.0 350 3 62.69 100.93 189 26.4 143.46 130.54 432.5 54.1
EST10CD6 10 9.2~10.8 300 2*1.1 350 3 69.65 112.13 210 29.1 159.68 145.3 481.4 59.5
EST12CD6 12 10.8~13 290 2*1.5 350 2*2.2 83.85 134.99 252.8 36.1 194.64 177.12 586.8 88.3
EST15CD6 15 13~15.4 410 2*1.5 400 2*3.0 99.71 160.53 300.6 43.2 232.69 211.74 701.5 100.1

Model Air Flow Volume Motor-internal Linked Motor-external Linked  Return Air Fresh Air
Rated Air Flow Air Flow Range Pressure Power
 Input
Pressure Power
 Input
Cooling 
Capacity
Heating 
Capacity
Water 
Flow
Water 
Resistance
Cooling 
Capacity
Heating 
Capacity
Water 
Flow
Water 
Resistance
×1000  CMH Pa kW Pa kW kW L/min kPa kW L/min kPa
EST2CD8 2 1.7~2.2 60 0.32 150 0.55 19.43 31.28 58.6 4.6 37.71 34.31 113.7 15.6
EST2.5CD8 2.5 2.2~2.7 165 0.45 180 0.55 21.59 34.75 65.1 5.7 46.3 42.13 139.6 17.5
EST3CD8 3 2.7~3.2 150 0.55 200 0.75 23.61 38.01 71.2 6.8 54.93 49.98 165.6 19.1
EST3.5CD8 3.5 3.2~3.7 165 0.75 200 1.1 29.32 47.2 88.4 8.2 65.57 59.66 197.7 21.8
EST4CD8 4 3.7~4.4 150 0.75 250 1.1 35.06 56.44 105.7 9.5 76.25 69.38 229.9 24.5
EST5CD8 5 4.4~5.4 210 1.5 250 1.5 43.75 70.43 131.9 11.8 93.74 85.3 282.6 28.9
EST6CD8 6 5.4~6.4 150 2*0.55 300 2.2 52.54 84.58 158.4 17.2 113.17 102.98 341.2 35.8
EST7CD8 7 6.4~7.4 165 2*0.75 300 2.2 61.33 98.74 184.9 23.1 132.58 120.64 399.7 43.4
EST8CD8 8 7.4~8.4 150 2*0.75 300 2.2 70.12 112.89 211.4 29.1 151.95 138.27 458.1 57.9
EST9CD8 9 8.4~9.2 310 2*1.0 350 3 78.94 127.09 238 32.3 171.36 155.93 516.6 64.4
EST10CD8 10 9.2~10.8 280 2*1.1 350 3 87.73 141.24 264.5 35.6 190.73 173.56 575 70.9
EST12CD8 12 10.8~13 270 2*1.5 350 2*2.2 105.61 170.03 318.4 44.2 232.46 211.53 700.8 105.2
EST15CD8 15 13~15.4 390 2*1.5 400 2*3.0 125.55 202.13 378.5 47.6 277.9 252.88 837.8 119.6


4.Eurostars Quotation Remarks-Air handling unit
*1.Packing: Standard export package
*2.Delivery Day: 20 working days after deposit is confirmed
*3.Delivery term: CIF,FOB or CNF EX-Work are welcomed
*4.Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
  Or 100% Irrevocable non-transferred LC at sight
*5.Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
*6.Validity: 20 days
*7.Payment currency: USD
 
5.CERTIFICATE-- CE certificated

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier