Guangdong, China
Business Type:
Manufacturer/Factory
Terms of Payment:
LC, T/T, Western Union
OEM/ODM Availability:
Yes
OEM/ODM Service

Fan Coil, Wall Mounted Fan Coil, Fan Coil Unit manufacturer / supplier in China, offering 2.85kw Hot Selling Wall Mounted Split Fan Coil Unit for Hotel Room, 3.6kw Ceiling Suspended Floor Standing Fan Coil Unit with Remote Controller (EST400CF2), Fresh Air Air Handling Unit Air Handler with Plate Heat Exchanger for Hotel and so on.

Diamond Member Since 2015
Audited Supplier
Supplier Homepage Products Fan coil/Fan Coil Unit 2.85kw Hot Selling Wall Mounted Split Fan Coil Unit for Hotel Room

2.85kw Hot Selling Wall Mounted Split Fan Coil Unit for Hotel Room

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $85-165/ Piece
Production Capacity: 8000 PCS/Year
Transport Package: Standard Export Packing, Such as Cartons
Payment Terms: L/C, T/T, Western Union
Type: Fan Coil Unit
Air Tube Material: Plastics
Corrosion Durability: Higher
Operating Voltage: 110V/220~240V-50Hz/60Hz-1pH
Noise Level: Low
Application Fields: HVAC

You Might Also Like

Loading...

Basic Info

Model NO.
EST300WM2
Mounting
Split
Lifetime
>20 years
Certification
CE
Condition
New
Color
White
Pipe System
Two Pipe System
Controller
Remote Controller
Plug
Customized
Trademark
Eurostars
Specification
CE Approval
Origin
Guangdong, Prc.
HS Code
84159010
2.85KW Hot Selling Wall Mounted Fan Coil for Hotel Room

1. High wall mounted split fan coil features:
(1)Low noise; (2) High efficient and energy saving; (3) Flexible installation; (4) Easy operation;(5)Compact exterior.

In central air conditioner system, Eurostars high wall mounted split fan coil continuously exchanges the indoor air with cool & heat supplied by chiller system, in order to adjust the room temperature and humidity. Vertical floor standing fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.

2. High wall mounted split fan coil main components introduction:
2.85kw Hot Selling Wall Mounted Split Fan Coil Unit for Hotel Room

3. High wall mounted split fan coil unit nomenclature

ES  T   300    WM2    T     A     O   
1    2      3         4         5      6     7      
1: ES Eurostars
2 :T Terminal series
3 :300 Rated air flow: CFM
4 :WM2 Wall mounted split type and the number of pipe system
5 :T Coil type:  T-2C0H (Note: C-Cold water coil; H-Hot water coil)                                    

6: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ
7 :O Sales region: O-Other regions;  C-Mainland China


4. Eurostars high wall mounted split fan coil techinal specification
Please ask salesman for detailed complete data or visit our website:
www.eurostarschina.com

Wall Mounted Split Fan Coil Unit (2 pipe system)
         Model  EST~300WM2400WM2500WM2600WM2
Air flow  m3/h5106808501020
CFM300400500600
 Cooling  capacityHW2850370047005600
BTU9727126281604119113
MW2500270035504550
BTU853392151211615529
LW1860220028003900
BTU63487509955613311
 Heating capacityHW4300549069308220
BTU14676187372365228055
MW3820400052606820
BTU13038136521795223277
LW2800375042006050
BTU9556127991433520649
Water flow  kg/h6007709601190
Input power  W 52627696
Noise level    dB(A)39414345
Pressure of outlet12Pa
FanType Centrifugal,double suction impeller 
Qty2222
MotorTypeHigh-precision, Low noise;Single-phase capacitance
Qty1111
Power supplyAC220V/1  50HZ
Protection classIP20
Insulated classE
Heat exchangerType Ripple Aluminum Fins Around Copper Pipe
Working pressure1.6MPa
Testing pressure3.3MPa 
Pipe Water inlet pipeZG3/4       internal thread
Water outlet pipeZG3/4       internal thread
Condensing pipeZG3/4       internal thread
Note:
(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)Heating: Inlet air temperature DB 21°C, heating water inlet temperature  60°C (tested by the same water flow with cooling condition).
(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.
(4)Rated air flow is tested in standard air condition with DB 20ºC.
(5)Specifications are subject to product improvement and change without notice.

5. 
High wall mounted split fan coil views 
2.85kw Hot Selling Wall Mounted Split Fan Coil Unit for Hotel Room
 
6.Eurostars high wall mounted split fan coil unit quotation remarks
(1)Packing: Standard export package
(2)Delivery Day: 10~25 working days after deposit is confirmed
(3)Delivery term: CIF,FOB or CNF EX-Work are welcomed
(4)Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
  Or 100% Irrevocable non-transferred LC at sight
(5)Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
(6)Validity: 20 days
(7)Payment currency: USD

7. 
High wall mounted split fan coil unit hotel project case
2.85kw Hot Selling Wall Mounted Split Fan Coil Unit for Hotel Room
 

Send your message to this supplier

*From:
*To:
avatar Mr. John
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now