Modular Air Handling Unit for Medical ICU Room

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
  • Modular Air Handling Unit for Medical ICU Room
  • Modular Air Handling Unit for Medical ICU Room
  • Modular Air Handling Unit for Medical ICU Room
  • Modular Air Handling Unit for Medical ICU Room
  • Modular Air Handling Unit for Medical ICU Room
  • Modular Air Handling Unit for Medical ICU Room
Find Similar Products

Basic Info.

Model NO.
EST50HC4
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Air-Conditioning (HVAC)System
Mounting
Floor Standing
Lifetime
>20 years
Certification
ISO, CE
Condition
New
Cooling/ Heating Coil 1
Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr
Base
C-Channel Hot DIP Base
Ahu Construction
25mm/ 50mm/ 75mm Double Skin
Optional 1
VSD, VFD
Optional 2
Heat Recovery Wheel
Control
Option for PLC, Ddc
Cooling/ Heating Coil 2
Copper Tube with Copper Fins (Cu/Cu), Gi/SUS Frame
Ahu Panels
Painted Steel, Gi, Ss Panels
Filters
Pre-Filter, Bag Filter, HEPA Filter
PU Foam Insulation
43-48kg/M3
Ahu Framework
Aluminum
Fan
Belt Drive Centrifugal Fan, Plug Fan,Ec Fan
Cold Bridge Free Design
Yes
Side Sliding Filter with Tracks
Yes
Optional 3
Ep, Chemical Filter, Plasma Sterilizer, Ak
Transport Package
Standard Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8415830000
Production Capacity
2000pieces/Year

Product Description

1.Eurostars air handling unit and air handler features
1) AHU case is the high-strength aluminum alloy frame, with built-in insulation materials, no cold bridges.
2) The aluminum material surface treated by anodizing looks nice and corrosion-resistant.The panel is 25mm thick and of double skin structure.Both the inner and outer panel plates are made of quality Korean galvanized steel painted, beautiful and fashionable design
3) The sandwiched PU foam insulation material between the plates ensure the best performance of insulation, intensity, rigidity, cleanliness and noise insulation for the AHU, and ensure no condensed water on the surface
4) In the gap between the frame and the panel moisture-proof material has been used to seal up, avoid air leakage and energy loss
5) The base frame is hot-dip galvanized steel, Anti-corrosive


2.Eurostars Air handler,air handling unit, ahu application
The AHU is used to control the following parameters of the space.
Temperature
Humidity
Air Movement
Air Cleanliness


3.Air handler technical data, Assembly drawing diagram and photo
Horizontal Air Handling Unit(Return Air Condition-4 Rows)
Model Air Flow Total
Pressure
Power Input Return Air
Cooling Capacity Heating Capacity Water Flow Water Resistance Water inlet/outlet pipe Diameter
*1000CMH Pa KW KW L/min KPa DN
EST10HC4 10 350 2.2 60.4 84 172.8 18.6 50
EST12HC4 12 400 3 73 101.7 209.4 21.6 50
EST15HC4 15 400 4 98.6 138.9 282.6 22.5 65
EST18HC4 18 400 5.5 118.3 165 339.6 24.5 65
EST20HC4 20 400 5.5 139.5 194.4 400.2 30.4 65
EST23HC4 23 400 5.5 157.9 219.9 456 25.5 65
EST25HC4 25 400 7.5 169.5 236.3 486.6 37.2 80
EST28HC4 28 500 2*4 186.3 259.7 534 26.5 80
EST30HC4 30 500 2*5.5 199.3 277.9 571.8 22.5 2*65
EST35HC4 35 500 2*5.5 235.7 328.3 676.2 29.4 2*65
EST40HC4 40 500 2*5.5 271.2 378 778.2 34.3 2*65
EST45HC4 45 500 2*7.5 286.2 398.8 821.4 40.2 2*65
EST50HC4 50 600 2*11 322.7 449.8 925.8 51.9 2*80
NOTE:
1.Return air:Cooling:Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC;
2.Return air:Heaing:Air in 15ºC DB,Hot water in:60ºC.
Modular Air Handling Unit for Medical ICU Room
4.Eurostars air handling unit , air handler range or series
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modular Modulus Air Handling Unit-multi-function air handling unit
Modular Air Handling Unit for Medical ICU Room
5.Components-air handling unit or air handler

Housing

--The housing that contains all the other components of an AHU is usually make of metal, some are painted to prevent corrosion.
In sections where the fans and the coil are located, 1-2 inches of polyurethane foam or PU is used to insulate them to prevent the condensation on the panel.Drain pan is also used as a precaution in the event of condensation of water.
--Penta-post extra heavy gauge aluminum profiles and strong fiber-reinforced PE corner connection forming the structural  frame
--superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation
--Thermal bridge free design, the profiles filled with polyurethane foam for insulation
--Anodizing surface treatment for profiles, corrosion-resistant
--Stainless steel frame available
Modular Air Handling Unit for Medical ICU Room
Fan
Centrifugal fan is used to circulate the air to the various parts of the sections in the building.The typical types of fan available are Backward Inclined, Backward Curved, Forward Curved and Airfoil.

The selection of the fan will depend on the air volume and the static pressure required of the system.Usually, the designer of the system will use a specialized software to do this selection.

In order to reduce the effect of vibration on the panel, the motor and the fan are usually installed on the vibration isolator except when the drive assembly is external to the fan casing.

In recent years, the use of variable air volume (VAV) system is becoming more popular as the volume of the air being discharged can be varied depending on the load condition.If the load is high, the fan speed will be higher and if the load is lower, the speed of the fan will be lower.

The speed of the fan is varied by using frequency inverter instead of conventional motor such as PSC motor.Frequency inverter provides better control of the fan speed as a whole range of fan speed from super low to super high can now be utilized based on the load conditions required.

This technology has enabled better use of energy and is in tandem with the move to go for greener energy.
Modular Air Handling Unit for Medical ICU Room
Vibration Eliminator
• To reduce the transmission of vibration and noise, fan and motor are installed on an independent complete base frame
• The complete base frame is isolated by deflection type spring isolators
• This unique structure not only reduce the vibration and noise, but also protect fan and motor during transportation

Modular Air Handling Unit for Medical ICU Room
Cooling Coil
Cooling Coil is used to cool and dehumidify the air.Both DX (direct expansion) cooling and CW (chilled water) cooling coils are available for use depending on the system design.

These coils are arranged in rows with different fin spacing.Aluminum fins and copper tubes are used in the design of the coils.The corrosion resistance hydrophilic fins are also used due to its lower cost and lower resistance to the air velocity.

Modular Air Handling Unit for Medical ICU Room
Filters
Filters are to remove particles and contaminants of various sizes from the air.The type of air filter being used will very much depend on the application of the system.
Panel Filter is a flat and rectangular in shape and provides a minimum low efficiency filtration which is acceptable to the air conditioning industry.The high velocity filter is arranged vertically whereas the low velocity filter is arranged in V shape.Typical air velocity that moves through the filters is in the range of 2-3 m/s.

Modular Air Handling Unit for Medical ICU Room
Stainless Steel Drain Pan
• Slop type design, no drain water carryover and keep the pan dry
• Avoid the micro-organisms growth inside the drain pan
Antimicrobial Drain Pan is offered as option
• SteriTouch technology Drip Pan Coating
• Antimicrobial surface
• Good exterior durability and corrosion resistance
• Excellent adhesion
• Non-toxic, comply with BS476 part 7
Modular Air Handling Unit for Medical ICU Room
Electrical control cabinet(optioanl)
•According to the requirements and functions of the unit to design the control console or cabinet
•Auto control each section of the unit to make sure the temperature, humidity and cleaness
•High quality and international brand electrical elements
•DDC and PLC available

6.Why choose us?
Eurostars offers Services:
•Consultancy
•System Design
•Technical support
•Customized manufacturing
•General testing before delivery
•Spare parts supply according to order quantity
•Long warranty period
•OEM service available

Modular Air Handling Unit for Medical ICU Room
7.FAQ
Q:What are the differences between an air conditioner and an air handler?
Air handlers are an important part of your overall HVAC system, but they are not the complete air conditioning system.

An air handler is responsible for housing the equipment necessary to move air through your home or business.In most cases, it is located inside and operates both the heating and cooling systems.Air handlers look like a furnace, and are sometimes even mistaken for one.Air handlers can be made to work with a heat pump or air conditioner.It includes the indoor coil, which depending on the setting your system is running on, is used for both heating and cooling.

Air conditioning units include the condenser and are usually kept outside of your home or business.Air conditioners actively pull heat out of the building through a variety of components configured together, and then this hot air is redirected outside.Throughout the process, air moves through the system via return ducts and over a refrigerant coil.Instead of adding cold air to the room, which is what it feels like, the system is actually just pulling hot air out and then recirculating the same air (without the heat) back into the building.


8.Customer visit us
Modular Air Handling Unit for Medical ICU Room
9.Air handling unit,air handler delivery or container loading
Modular Air Handling Unit for Medical ICU Room
10.Installation instruction or installation photo, project photos
---1. During installation, enough space should be reserved around the unit, especially aside the access door and water pipe, for the repair machine passing. 
---2. The unit should be mounted on flat base (concrete or welded C-channel).  Drainages are available around the base.
---3. Floor drain should be set in the machine room for the discharge of condensing water and washing water.
---4.Pay attention to condensing water discharging; to ensure the condensing water discharge smoothly.
---5. The unit should be installed on a horizontal platform or hanger.  After the unit is installed, connect the kinds of pipes and ducts:
A. The chilled water pipe connection with cooling coil;
B. The condensing water drain pipe connection;
C. Humidifier pipes connection;
D. The connection for the fresh/return air inlet with its air ducts;
E. The wiring connection for the control box.
When connecting the air duct, 100-150mm flexible connection (airtight canvas or artificial leather cloth) should be set between flange and air inlet/outlet, to avoid the air leakage caused by the unit vibration.

The control box normally is installed on the unit cabinet or in the machine room. Please make the wiring according to the related electrical regulation by your country.

---6.After all water pipe, wirings and air duct are correctly connected, the air handling unit can be started.
[ !]The first time starting should be instructed by an experienced person at site, non-experienced person can't operate the equipment without permit.  The defect caused by misuse shall not be our obligation;
[ !] Before first time starting, please remove the temporary fixing plate from the fan and motor;
[ !] The power and voltage supply must be compatible with the unit.  After connecting the power to the motor, start motor first, then check the running direction of the fan. If it is running in opposite direction, please stop and change the phase sequence, then connect the power to motor finally. If there is protection device on the supply fan motor, the motor raring should be connected to ground.  The motor in this unit use "reduced voltage starting".
---7. Adjustment of the driving belt
---8. Before moving the unit, please fasten the damping device.  Putting down should be slowly to make sure that the damping device is forced evenly to protect the damping device.  The connection between damping device and the unit should not be by welding

Modular Air Handling Unit for Medical ICU Room

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier