Heat Recovery Water Cooled Chiller Water Source Heat Pump

Product Details
Customization: Available
Energy Efficiency Grade: Two
Heat Temperature: 50-70°C
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
Find Similar Products

Basic Info.

Model NO.
ESGW195DOQN
Work Environment
Common Heat Pump
Heat Source
Water-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, CCC, SGS
Heat Pump Compresor
Taiwan Hanbell
Heat Pump Expansion Valve
Emerson
Heat Pump Dry Filter
Danfoss
Optional
Partial Heat Recovery
Compressor Quantity
1 or 2
Transport Package
Standard Export Package
Specification
CE
Trademark
Eurostars
Origin
Guangdong, Prc.
HS Code
8418692090
Production Capacity
1000 PCS/Year

Product Description

Heat Recovery Water Cooled Chiller Water Source Heat Pump

1.Brief introduction-Eurostars water source heat pump with heat recovery
a)Underground water source
b)Intellectualized control system and low noise
c)High efficient and energy saving
d)Easy operation and installation
e)Compact exterior
f)High quality
g)Competitive price
h)Cooling in summer, Heating in Winter, Sanitary hot water all year round.
 
2.Unit Features-Eurostars water source heat pump with heat recovery
1).Heating capacity ranged from 212Kw to 3407 Kw.
2). Adopt good quality famous brand Hanbell screw compressor,high efficiency, low noise, less wearing and long life
3).Both Evaporator and Condenser are high quality and high efficiency
4). World famous brand parts: such Emerson expansion valve, FUJI contactor other brand like PUNP, Schneider.
5). Can be widely used in different area,such as Massage center, Hospital, Hotel, School, etc 
6). Strong unit base frame ensured the equipment stable operation 
7). Adopt leading brand PLC or SCM controller
8). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.
 
3.Technical parameter-water cooled water source heat pump with heat recovery
Please ask salesman for detailed complete data 
or visit our website: eurostarschiller.en.made-in-china.com
Screw-type Water Source Heat Pump with Heat Recovery (two compressors)
Model   ESGW 055DOQN 130DOQN 140DOQN 195DOQN 285DOQN 315DOQN 335DOQN 350DOQN
Rated Cooling Capacity Cooling Capacity (KW)  212 497 543 742 1094 1210 1290 1349
Cooling Capacity (USRT)  60.30  141.35  154.44  211.04  311.15  344.14  366.89  383.67 
Input Power (KW) 37.8 83.8 92.0 119.5 175.2 194.9 206.7 217.7
Rated Heating Capacity Heating Capacity (KW) 253 585 640 865 1126 1411 1501 1573
Heating Capacity (USRT) 71.96  166.38  182.03  246.02  320.25  401.31  426.91  447.38 
Input Power (KW) 53.4 117.8 129.2 167.0 245 272.3 288.6 304.2
Refrigerant R407C
Compressor Semi-hermetic  Screw Type
Power Supply  3φ-380V-50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection,
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit 2
Capacity Control (%) 0,25,37.5,50,62.5,75,87.5,100
Refrigerant Charge (Kg) 34 80 87 118 179 194 209 219
Chilled Water Temp of inlet/outlet water 12ºC/7ºC
Water Side Max Pressure (MPa)
Dia.of Pipe  (inch)  3" 5" 5" 5" 6" 6" 8" 8"
Water Flow (m3/h) 36.5  85.5  93.4  127.6  188.2  208.1  221.9  232.0 
Pressure drop (kPa)  29 39 49 40 43 48 47 51
Under Ground Water Temp of inlet/outlet water 18ºC/29ºC
Water Side Max Pressure (MPa) 1
Dia.of Pipe  (inch)  3" 4" 5" 5" 4"×2 5"×2 5"×2 5"×2
Water Flow (m3/h) 19.8 45.8 50 67.6 88 110.3 117.3 123
Pressure drop (kPa)  41 43 44 45 46 47 50 53
Running Noise dB(A) 76.1 82.0 82.2 83.4 88.2 89.3 89.6 89.9
Total weight (Kg) 1410 2260 2540 2930 3740 3950 4320 4810
Running Weight (Kg) 1790 2970 3330 3920 4830 5140 5540 5750
Heat Recovery Parameters
Refrigerant Charge (Kg) 34 80 87 118 179 194 209 219
Heat Reclaimed Volume  (KW) 63.6  149.1  162.9  222.6  328.2  363.0  387.0  404.7 
Heat Recovery unit Water Side Max Pressure (MPa) 1
Dia.of Pipe  (inch)  2" 2-1/2" 2-1/2" 2-1/2" 3" 3" 3" 3"
Water Flow (m3/h) 10.9  25.6  28.0  38.3  56.5  62.4  66.6  69.6 
Pressure drop (kPa)  23 26 26 29 34 35 38 39
Total weight (Kg) 1550 2510 2810 3330 3910 4470 4910 5360
Running Weight (Kg) 1950 3240 3580 4280 4970 5660 5920 6160
Dimension L×W×H Detailed dimensions are according to the actual finished product sizes.
 
Screw-type Water Source Heat Pump with Heat Recovery (two compressors)
Model ESGW 405DOQN 445DOQN 480DOQN 535DOQN 675DOQN 790DOQN 885DOQN
Rated Cooling Capacity Cooling Capacity (KW)  1570 1723 1850 2064 2592 3053 3407
Cooling Capacity (USRT)  446.53  490.05  526.17  587.03  737.20  868.32  969.00 
Input Power (KW) 250.6 275.3 293.4 327.2 412.7 483.2 533.9
Rated Heating Capacity Heating Capacity (KW) 1825 2005 2147 2396 3013 3543 3945
Heating Capacity (USRT) 519.06  570.25  610.64  681.46  856.94  1,007.68  1,122.01 
Input Power (KW) 350.2 384.6 409.8 457.1 576.5 675.1 745.8
Refrigerant R407C
Compressor Semi-hermetic  Screw Type  
Power Supply  3φ-380V-50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection,
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit 2
Capacity Control (%) 0,25,37.5,50,62.5,75,87.5,100
Refrigerant Charge (Kg) 255 281 300 336 414 486 558
Chilled Water Temp of inlet/outlet water 12ºC/7ºC
Water Side Max Pressure (MPa)
Dia.of Pipe  (inch)  8" 8" 8" 8" 8" 10" 10"
Water Flow (m3/h) 270.0  296.4  318.2  355.0  445.8  525.1  586.0 
Pressure drop (kPa)  55 71 69 66 64 71 76
Underground Water Temp of inlet/outlet water 18ºC/29ºC
Water Side Max Pressure (MPa) 1
Dia.of Pipe  (inch)  5"×2 5"×2 5"×2 6"×2 6"×2 8"×2 8"×2
Water Flow (m3/h) 142.7 156.7 167.9 187.3 235.5 276.9 308.4
Pressure drop (kPa)  59 61 67 74 76 80 85
Running Noise dB(A) 90.1 90.3 90.6 91.4 93.3 93.8 94.2
Total weight (Kg) 5270 5680 5890 6110 7380 8010 8550
Running Weight (Kg) 5970 6190 6500 6810 8420 9180 9720
Heat Recovery Parameters
Refrigerant Charge (Kg) 255 281 316 354 436 512 584
Heat Reclaimed Volume  (KW) 471 516.9 555 619.2 777.6 915.9 1022.1
Heat Recovery unit Water Side Max Pressure (MPa) 1
Dia.of Pipe  (inch)  4" 4" 4" 4" 5" 5" 5"
Water Flow (m3/h) 81.0  88.9  95.5  106.5  133.7  157.5  175.8 
Pressure drop (kPa)  42 42 43 43 43 43 43
Total weight (Kg) 5820 6290 6620 6840 7610 8440 8980
Running Weight (Kg) 6470 6790 7220 7440 8660 9520 10080
Dimension L×W×H   Detailed dimensions are according to the actual finished product sizes.

(1).Rated Cooling Capacity Based on: Underground water in/outlet temp 18ºC/29ºC;Chilled water in/outlet temp. 12ºC/7ºC,  Fouling factor: 0.088.°C/KW.
(2).Rated heating capacity based on:Underground water inlet temp. 15°C;Hhot water inlet temp. 40°C.

4.Eurostars water cooled water source heat pump water chiller protection devices
1)Phase reversion protection, 
2)Overload current protection,
4)Phase lack protection, 
5)Discharge air temp. protection, 
6)Low&High pressure protection, 
7)Reserved water flow protection interface,
8)Low temp. protection.

5.Eurostars water source heat pump chiller series
-Commercial Water Source Heat Pump Chiller
-Scroll type water cooled water source heat pump
-Screw type water cooled water source heat pump
-Flooded type water cooled water source heat pump
 
-Commercial Air Cooled Heat Pump Chiller
-Scroll type air cooled air source heat pump
-Screw type air cooled air source heat pump
 
-Cooling&Heating&Sanitay hot water
-Air source heat pump with heat recovery
-Water source heat pump with heat recovery
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier