  • European Super Thin Design Floor Standing Exposed Fan Coil Unit
  • European Super Thin Design Floor Standing Exposed Fan Coil Unit
  • European Super Thin Design Floor Standing Exposed Fan Coil Unit
  • European Super Thin Design Floor Standing Exposed Fan Coil Unit
  • European Super Thin Design Floor Standing Exposed Fan Coil Unit
  • European Super Thin Design Floor Standing Exposed Fan Coil Unit
Find Similar Products

Basic Info.

Model NO.
EST600VE2
Operating Voltage
230 VAC
Noise Level
Ultra Low
Application Fields
Villa/Restaurant/Hotel Room/Building
Mounting
Floor Standing
Lifetime
>20 years
Certification
CE, CCC
Condition
New
Fan Coil Unit Type
Vertical Exposed Fan Coil Unit
Pipe System
Two Pipe System
Thickness
130 mm
Optional
DC Motor
Inbuilt
Digital Thermostat
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Trademark
Eurostars
Origin
Guangdong, Prc.
HS Code
84159010
Production Capacity
10000 PCS/Year

Product Description

European Super Thin Design Floor Standing Exposed Fan Coil Unit

Floor mounted fan coil unit, Horizontal concealed fan coil unit, cassette fan coil unit, ceiling floor fan coil unit, wall mounted fan coil unit, ceiling suspended fan coil unit

1. Ultra-thin vertical exposed fan coil unit features:
(1)Ultra thin design,the thickness of fan coil unit is only 130mm.(see as below,less than IPHONE 5 length);
(2) Air return direction is selectable,side air return and bottom air return is optional,adjust to fit different environment;
(3) Air flow can becontrolled in a breeze status,very quiet; it is the best alernative to the radiator:
a. Radiators only offer heating,but our ultra thin fan coil unit can offer heating and cooling;
b.Radiators's heating speed is slow and radiation is narrow,inefficient air convection;Fan coil unit have higher heat exchange speed,therefore fan coil unit can create more uniform temperature field space.
(4)Standard design with inbuilt digital room thermostat.Without room thermostat is optional,user need prepare thermostat;
(5)Unit standard design is manual adjusting to air flow;auto swing is optional must with DC motor;
(6)Left or right water connection direction can be selected;
(7)Left and right side panels can be removed independently.It is easy for installation and maintenance;
(8)Easy-removable and washable filter was in-built.

In central air conditioner system, Eurostars ultra thin vertical exposed fan coil continuously exchanges the indoor air with cool & heat supplied by chiller system, in order to adjust the room temperature and humidity. Vertical floor standing fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.

2. Eurostars Ultra-thin vertical exposed fan coil unit nomenclature

ES  T   200    VE2     T     R      0   A    O   
1    2      3       4         5      6     7    8   9 
1: ES Eurostars
2 :T Terminal series
3 :200 Rated air flow: CFM
4 :VE2 Vertical exposed and the number of pipe system
5 :T Coil type:  T-2C0H (Note: C-Cold water coil; H-Hot water coil)                                    
6 :R Connection pipe direction: R-Right (face to air outlet)  L-Left (face to air outlet)
7 :0 Built-in electrical heating power: 0-None;
8: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ
9 :O Sales region: O-Other regions;  C-Mainland China

3. Eurostars ultra thin fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
Vertical Exposed Fan Coil Unit(Ultra thin type)
Model EST 200VE2 300VE2 400VE2 500VE2 600VE2
Air flow (m³/h) High  200 300 400 500 600
Low  80 120 180 220 260
Rated cooling capacity W 1000 1900 2800 3500 4000
BTU 3413 6485 9556 11946 13652
Rated heating capacity(1) W 1500 2850 4200 5250 6000
BTU 5120 9727 14335 17918 20478
Rated heating capacity (2) W 2000 3800 5550 6950 8000
BTU 6826 12969 18942 23720 27304
Motor power input  W 18 24 35 40 45
Noise  dB(A) 30 32 36 38 40
Water flow m3/h 0.17  0.33  0.49  0.60  0.64 
 Water resistance  kPa 12 14 18 20 24
Heat exchanger Type copper tubes with shutter-type aluminum fins
Max. Working pressure 1.6MPa
Testing pressure Airtightness test under pressurized water: 3.3MPa
Pipe  Inlet/outlet water pipe R1/2 "external thread
Condensation water pipe φ21
Dimensions(L*W*H) mm 700*130*681 900*130*681 1100*130*681 1300*130*681 1500*130*681
Note:
(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)Heating1: Inlet air temperature DB 20°C, heating water inlet temperature  60°C
     Heating2: Inlet air temperature DB 20°C, heating water inlet temperature  70°C 
(tested by the same water flow with cooling condition).
(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.
(4)Rated air flow is tested in standard air condition with DB 20ºC.
(5)Specifications are subject to product improvement and change without notice.