Ultra-Silent Horizontal Concealed Duct Fan Coil Unit for Hotel Room (EST400HC2)

Product Details
Customization: Available
Type: Fan Coil Unit
Air Tube Material: Galvanized Sheet
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
  • Ultra-Silent Horizontal Concealed Duct Fan Coil Unit for Hotel Room (EST400HC2)
  • Ultra-Silent Horizontal Concealed Duct Fan Coil Unit for Hotel Room (EST400HC2)
  • Ultra-Silent Horizontal Concealed Duct Fan Coil Unit for Hotel Room (EST400HC2)
  • Ultra-Silent Horizontal Concealed Duct Fan Coil Unit for Hotel Room (EST400HC2)
  • Ultra-Silent Horizontal Concealed Duct Fan Coil Unit for Hotel Room (EST400HC2)
  • Ultra-Silent Horizontal Concealed Duct Fan Coil Unit for Hotel Room (EST400HC2)
Find Similar Products

Basic Info.

Model NO.
EST400HC2
Operating Voltage
110V/220~240V-50Hz/60Hz-1pH
Noise Level
Low
Application Fields
Restaurant/Hotel Room
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
CE
Condition
New
Pipe System
Two Pipe and Four Pipe System
Air Outlet Static Pressure
0,12, 30,50PA
Air Return
Backward/Downward
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Trademark
Eurostars
Origin
Guangdong, Prc.
HS Code
84159010
Production Capacity
10000 PCS/Year

Product Description

Ultra-silent Horizontal Concealed Duct Fan Coil Unit for Hotel Room(400HC2)
1. Horizontal concealed fan coil features:
(1)Low noise-high quality reliability fan motor;
(2) High efficient and energy saving-seamless copper tube mechanically expanded to aluminum shutter fins;
(3) V shape designed drainage pan;
(4)Professional designed water connector;
(5) Flexible installation and easy operation.
In central air conditioner system, Eurostars ceiling duct horizontal concealed fan coil continuously exchanges the indoor air with cool & heat supplied by chiller system, in order to adjust the room temperature and humidity. Vertical floor standing fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.

2. Eurostars horizontal concealed fan coil main components introduction:
Ultra-Silent Horizontal Concealed Duct Fan Coil Unit for Hotel Room (EST400HC2)
3. Eurostars horizontal concealed ducted fan coil nomenclature
ES  T   200    HC2     C     R      B  A    O   
1    2      3       4         5      6     7    8   9 
1: ES Eurostars
2 :T Terminal series
3 :200 Rated air flow: CFM
4 :HC2 Horizontal exposed and the number of tube system
5 :C Coil type:  C-3C0H; T-2C0H (Note: C-Cold water coil; H-Hot water coil)                                    

6 :R Connection pipe direction: R-Right (face to air outlet)  L-Left (face to air outlet)
7 :B Return air box type: C-None;  B-Backward return air box  D-Downward return air box
8: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ
9 :O Sales region: O-Other regions;  C-Mainland China


4. Eurostars ceiling horizontal concealed fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
Horizontal Concealed Fan Coil Unit (2 pipe system)
Model EST~ 200HC2 300HC2 400HC2 500HC2 600HC2 800HC2 1000HC2 1200HC2 1400HC2
Air flow (m3/h)
(0/12Pa,30Pa,50Pa Static Pressure)
High  340 510 680 850 1020 1360 1700 2040 2380
Medium  255 383 510 638 765 1020 1275 1530 1785
Low  170 255 340 425 510 680 850 1020 1190
Rated cooling capacity  H TH(W) 1800 2700 3600 4500 5400 7200 9000 10800 12600
SH(W) 1311 1971 2700 3184 4196 5362 6707 8072 9070
M TH(W) 1500 2460 3000 3715 4423 6435 7848 9296 10500
SH(W) 994 1555 1995 2426 3041 4236 5393 6603 7190
L TH(W) 1391 2057 2479 2921 3793 5604 7223 8534 8900
SH(W) 823 1200 1530 1826 2373 3284 4416 5248 5500
Rated heating capacity (H) W 2700 4050 5400 6750 8100 10800 13500 16200 18900
BTU 9215 13823 18430 23038 27645 36860 46076 55291 64506
Power input W 0/12Pa 37 52 62 76 96 134 152 189 228
30Pa 44 59 72 87 108 156 174 212 253
50Pa 49 66 84 100 118 174 210 250 300
Noise dB(A) 0/12Pa 37.00  39.00  41.00  43.00  45.00  46.00  48.00  50.00  52.00 
30Pa 40.00  42.00  44.00  46.00  47.00  48.00  50.00  52.00  54.00 
50Pa 42.00  44.00  46.00  47.00  49.00  50.00  52.00  54.00  56.00 
Heat exchanger Water flow m3/h 0.34  0.50  0.66  0.81  0.96  1.28  1.61  1.92  2.18 
Type copper tubes with shutter-type aluminum fins
Max working pressure 1.6MPa
Testing pressure Airtightness test under pressurized water: 3.3MPa
Pressure loss (KPa) 30 30 30 30 40 40 40 40 50
Fan Type  Forward-pitched multi-wing centrifugal fan with double-suction impellers made from zinc-plated steel plates
Qty 1 1 2 2 2 2 3 4 4
Motor Type Single-phase capacitive motor equips with fine ball bearing, low noise and long service life
Qty 1 1 1 1 1 1 2 2 2
Power supply 220V-/50HZ
Protection grade IP20
Insulation class B
Pipe  Inlet/outlet water pipe ZG 3/4 " (DN20)
Condensation water pipe ZG 3/4"   (DN20)
 Net weight Kg without plenum
 air box
13.00  15.00  16.00  17.00  19.00  22.00  29.00  31.00  34.00 
with plenum
air box 
18.50  21.00  22.50  24.00  27.00  32.00  42.00  45.00  50.00 
Horizontal Concealed Fan Coil (4 pipe system)
Model EST 200HC4 300HC4 400HC4 500HC4 600HC4 800HC4 1000HC4 1200HC4 1400HC4
Air flow (m3/h)
(12Pa,30Pa,50Pa 
Static Pressure)
High  340 510 680 850 1020 1360 1700 2040 2380
Medium  279 418 558 697 836 1115 1394 1673 1952
Low  170 255 340 425 510 680 850 1020 1190
Cooling capacity
(cold water coil) 
TH (H) W 2530 3310 4240 5000 5890 8040 9290 11820 13600
BTU 8635 11297 14471 17065 20103 27441 31707 40342 46417
SH (H) W 1490 2100 2850 3350 4040 5520 6730 8300 9920
BTU 5085 7167 9727 11434 13789 18840 22969 28328 33857
Rated heating capacity
(cold water coil)(H)
W 4180 5300 7030 7920 9890 13120 16120 20150 21810
BTU 14266 18089 23993 27031 33755 44779 55018 68772 74438
Rated heating capacity 1
(hot water coil)(H)
W 2450 3170 4090 4470 5690 7290 8790 11610 21810
BTU 8362 10819 13959 15256 19420 24881 30000 39625 74438
Rated heating capacity 2
(hot water coil)(H)
W 3330 4240 5800 6670 7970 10200 12270 16420 19570
BTU 11365 14471 19795 22765 27202 34813 41878 56041 66792
Power input W 12Pa 32 46 56 73 93 133 164 188 229
30Pa 41 53 72 86 107 142 183 217 239
50Pa 46 65 77 90 115 162 187 227 279
Running current A 12Pa 0.15  0.21  0.26  0.33  0.42  0.61  0.74  0.85  1.04 
30Pa 0.20  0.24  0.33  0.38  0.48  0.65  0.83  0.99  1.09 
50Pa 0.22  0.29  0.35  0.41  0.52  0.74  0.85  1.03  1.27 
Noise dB(A) 12Pa 33.50 32.50 38.50 41.50 44.50 45.00 48.00 49.00 53.00
30Pa 39.50 40.00 43.00 44.00 46.00 46.00 50.50 50.50 54.00
50Pa 42.00 43.00 45.00 46.00 47.50 48.50 50.50 52.50 54.50
Cold water coil Water flow (m3/h) 0.44 0.57 0.73 0.88 1.03 1.41 1.62 2.04 2.36
 Water resistance (cooling) kPa 14 29 17 24 33 34 26 44 48
Water resistance (heating) kPa 11 21 13 21 26 27 21 36 38
Hot water coil Water flow  (m3/h) 0.21 0.27 0.35 0.38 0.49 0.63 0.75 0.97 1.17
 Water resistance (heating) kPa 7 14 22 28 54 15 21 40 54
Water flow  (m3/h) 0.13 0.17 0.23 0.26 0.31 0.40 0.48 0.63 0.76
Water resistance (heating) kPa 3 6 10 14 20 7 10 18 25
Heat Exchanger Type copper tubes with shutter-type aluminum fins
Working pressure 1.6MPa
Testing pressure Airtightness test under pressurized water: 3.3MPa
Fan Type  Forward-pitched multi-wing centrifugal fan with double-suction impellers
made from zinc-plated steel plates
Qty 1 2 2 2 2 3 3 4 4
Motor Type  Single-phase capacitive motor equips with fine ball bearing, low noise and long service life
Qty 1 1 1 1 1 2 2 2 2
Power supply 220V/1PH/50HZ
Protection grade IP20
Insulation class B
Pipe  Inlet/outlet water pipe ZG 3/4 " internal thread
Condensation water pipe ZG 3/4"   external thread
 Net weight Kg without return
 air box
12.50  12.50  16.50  17.00  19.00  25.00  28.00  32.50  35.50 
with return
air box 
15.80  15.80  20.50  21.30  23.80  31.10  34.60  39.90  43.60 
Note:
(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)Heating: Inlet air temperature DB 21°C, heating water inlet temperature  60°C (tested by the same water flow with cooling condition).
(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.
(4)Rated air flow is tested in standard air condition with DB 20ºC.
(5)Specifications are subject to product improvement and change without notice.

5.Horizontal concealed fan coil unit dimension air flow properties
Ultra-Silent Horizontal Concealed Duct Fan Coil Unit for Hotel Room (EST400HC2)
6. Horizontal concealed fan coil unit wiring and installation instruction
Ultra-Silent Horizontal Concealed Duct Fan Coil Unit for Hotel Room (EST400HC2)
7. Eurostars fan coil unit series
((1)Wall mounted split fan coil unit
(2)Ceiling floor fan coil unit
(3)Horizontal concealed ceiling duct fan coil unit
(4)Horizontal exposed fan coil unit
(5)Ceiling cassette fan coil unit
(6)Vertical exposed fan coil unit
(7)Vertical concealed fan coil unit

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier