Water Chiller Chilled Water Air Handling Unit

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
Find Similar Products

Basic Info.

Model NO.
EST Series
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
HVAC
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
CE
Condition
New
Air Handling Unit
Bule/White Panel
Transport Package
Standard Package
Specification
CE
Trademark
Eurostars
Origin
Guangdong, Prc
HS Code
8415909000

Product Description

1.Selling Point-Air handling unit
a)Low Noise
b)Efficient and Energy Saving
c)Easy Operation and Installation
d)Compact Exterior
e)High quality
f)Competitive price
 
2.Product series-Eurostars chilled water fan coil-air handling unit
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modulus Air Handling Unit-multi-function air handling unit
 
3.Main parts introduction-air handling unit
Water Chiller Chilled Water Air Handling Unit

4.Typical Unit Assembly-air handling unit
Water Chiller Chilled Water Air Handling Unit
Water Chiller Chilled Water Air Handling Unit
5.Nomenclature-air handling unit
 
ES  T   2   HCX   H   e   L
1   2   3   4     5   6   7
1  ES Eurostars
2  T Product Series: T-Terminal series
3  2 License No: Rated Air Flow Volume(*1000m³/h)
4  HCX Installation way: HCX--Horizontal concealed; VCX--Vertical concealed; VEX--Vertical exposed CDX--Ceiling ducted; ASX--Assembly (X means the number of rows)
5  H Working conditions: H--Return Air; X--Fresh Air
6  e Ceiling type: None--Standard type; e--Ultra-thin type
7  L Inlet/outlet Water pipe direction: L--Left; R--Right
 
For example: Model EST-2CD-6X/e-R
It means AHU, Rated air flow volume is 2000m³/h, Horizontal ultra-thin ceiling ducted type,with coil 6 Rows, Fresh air conditions, Inlet water pipe is on the right.
 
6.Unit specification-air handling unit
Following is only one part of our whole air handling unit specification,please ask Eurostars salesman for other detailed specification.

Heat exchanger:4Rows
Model Air Flow Volume Motor-external Linked  Return Air
Rated Air Flow Air Flow Range Pressure Power Input Cooling Capacity Heating Capacity Water Flow Water Resistance Water inlet/outlet pipe Diameter
*1000CMH Pa kW kW L/min kPa DN
EST2HC4 2 1.7~2.2 150 0.55 11.44 18.41 34.5 3 32
EST3HC4 3 2.2~3.4 200 0.75 13.89 22.36 41.9 3.5 32
EST4HC4 4 3.4~4.4 250 1.1 20.63 33.21 62.2 4.7 40
EST5HC4 5 4.4~5.4 250 1.5 25.74 41.44 77.6 6.2 40
EST6HC4 6 5.4~6.7 300 2.2 30.91 49.76 93.2 8.5 40
EST8HC4 8 6.7~8.7 300 2.2 41.26 66.42 124.4 10.5 50
EST10HC4 10 8.7~10.8 350 3 51.61 83.09 155.6 14.5 50
EST12HC4 12 10.8~13 350 4 62.12 100.01 187.3 15.1 50
EST15HC4 15 13~15.4 400 5.5 73.87 118.93 222.7 15.8 65
EST16HC4 16 15.4~16.8 400 5.5 79.61 128.17 240 16.2 65
EST18HC4 18 16.8~18.8 400 7.5 91.05 146.59 274.5 16.4 65
EST20HC4 20 18.8~21.5 500 2*4 103.6 166.79 309 16.6 65
EST24HC4 24 21.5~25.5 500 2*5.5 130 209.3 387.8 16.8 2*65
EST27HC4 27 25.5~28.5 500 2*5.5 149.8 241.17 446.8 17.5 2*65
EST30HC4 30 28.5~31 500 2*7.5 169.6 273.05 505.9 18.3 2*65
EST32HC4 32 31~32.8 500 2*7.5 183.9 296.07 548.5 18.7 2*65
EST34HC4 34 32.8~34.8 550 2*7.5 195.8 315.23 584 19.1 2*65
EST36HC4 36 34.8~37.5 550 2*7.5 206.9 333.1 617.3 19.4 2*65
EST40HC4 40 37.5~42 600 2*11 230.8 371.58 681.5 20.2 2*65
EST45HC4 45 42~47 600 2*11 259 416.99 764.5 22.2 2*65
EST50HC4 50 47~52 650 2*11 287.2 462.39 848.1 25 2*65
EST55HC4 55 52~57 650 2*11 316.2 509.08 933.7 28.3 2*65
EST60HC4 60 57~64.5 700 2*15 345.4 556.09 1020 31.7 2*65
EST70HC4 70 64.5~75 700 2*15 402.4 647.86 1188 38.4 2*80

Heat exchangers:6Rows
Model Air Flow Volume Motor-external Linked  Return Air
Rated Air Flow Air Flow Range Pressure Power Input Cooling Capacity Heating Capacity Water Flow Water Resistance Water inlet/outlet pipe Diameter
*1000CMH Pa kW kW L/min kPa DN
EST2HC6 2 1.7~2.2 150 0.55 15.4 24.79 46.5 3.8 32
EST3HC6 3 2.2~3.4 200 0.75 18.7 30.1 56.5 4.4 32
EST4HC6 4 3.4~4.4 250 1.1 27.8 44.75 83.9 6 40
EST5HC6 5 4.4~5.4 250 1.5 34.7 55.86 104.7 7.9 40
EST6HC6 6 5.4~6.7 300 2.2 41.7 67.13 125.8 10.8 40
EST8HC6 8 6.7~8.7 300 2.2 55.7 89.67 167.9 13.4 50
EST10HC6 10 8.7~10.8 350 3 69.7 112.21 210 18.5 50
EST12HC6 12 10.8~13 400 4 83.9 135.07 252.8 19.2 65
EST15HC6 15 13~15.4 400 5.5 99.7 160.51 300.6 20.1 65
EST16HC6 16 15.4~16.8 400 5.5 107.5 173.07 324 20.7 65
EST18HC6 18 16.8~18.8 400 7.5 122.9 197.86 370.5 20.9 65
EST20HC6 20 18.8~21.5 500 2*4 139.8 225.07 417.1 21.2 65
EST24HC6 24 21.5~25.5 500 2*5.5 175.5 282.55 523.5 21.4 2*65
EST27HC6 27 25.5~28.5 500 2*5.5 202.2 325.54 603.1 22.3 2*65
EST30HC6 30 28.5~31 500 2*7.5 228.9 368.52 682.9 23.3 2*65
EST32HC6 32 31~32.8 500 2*7.5 248.2 399.6 740.4 23.9 2*65
EST34HC6 34 32.8~34.8 550 2*7.5 264.3 425.52 788.4 24.4 2*65
EST36HC6 36 34.8~37.5 550 2*7.5 279.3 449.67 833.3 24.7 2*65
EST40HC6 40 37.5~42 600 2*11 311.6 501.67 920 25.8 2*65
EST45HC6 45 42~47 600 2*11 349.6 562.85 1032.2 28.3 2*65
EST50HC6 50 47~52 650 2*11 387.8 624.35 1144.9 31.9 2*65
EST55HC6 55 52~57 650 2*11 426.9 687.3 1260.4 36.1 2*80
EST60HC6 60 57~64.5 700 2*15 466.3 750.74 1376.7 40.5 2*80
EST70HC6 70 64.5~75 700 2*15 534.2 874.5 1603.8 49 2*80

Heat exchangers:8Rows
Model Air Flow Volume Motor-external Linked  Return Air
Rated Air Flow Air Flow Range Pressure Power Input Cooling Capacity Heating Capacity Water Flow Water Resistance Water inlet/outlet pipe Diameter
*1000CMH Pa kW kW L/min kPa DN
EST2HC8 2 1.7~2.2 150 0.55 19.43 31.28 58.6 4.6 32
EST3HC8 3 2.2~3.4 200 0.75 23.61 38.01 71.2 5.4 32
EST4HC8 4 3.4~4.4 250 1.1 35.06 56.44 105.7 7.3 40
EST5HC8 5 4.4~5.4 250 1.5 43.75 70.43 131.9 9.7 40
EST6HC8 6 5.4~6.7 300 2.2 52.54 84.58 158.4 13.2 50
EST8HC8 8 6.7~8.7 300 2.2 70.12 112.89 211.4 16.4 50
EST10HC8 10 8.7~10.8 350 3 87.73 141.24 264.5 22.6 50
EST12HC8 12 10.8~13 350 4 105.61 170.03 318.4 23.6 65
EST15HC8 15 13~15.4 400 5.5 125.55 202.13 378.5 24.7 65
EST16HC8 16 15.4~16.8 400 5.5 135.33 217.88 408 25.3 65
EST18HC8 18 16.8~18.8 400 7.5 154.77 249.17 466.6 25.6 65
EST20HC8 20 18.8~21.5 500 2*4 174.24 280.52 525.3 25.9 65
EST24HC8 24 21.5~25.5 500 2*5.5 218.66 352.04 659.2 26.2 2*65
EST27HC8 27 25.5~28.5 500 2*5.5 251.93 405.6 759.5 27.3 2*65
EST30HC8 30 28.5~31 500 2*7.5 285.26 459.26 860 28.6 2*65
EST32HC8 32 31~32.8 500 2*7.5 309.28 497.94 932.4 29.2 2*65
EST34HC8 34 32.8~34.8 550 2*7.5 329.32 530.2 992.8 29.8 2*65
EST36HC8 36 34.8~37.5 550 2*7.5 348.09 560.42 1049.4 30.3 2*65
EST40HC8 40 37.5~42 600 2*11 384.28 618.69 1158.5 31.6 2*65
EST45HC8 45 42~47 600 2*11 431.15 694.15 1299.8 34.7 2*65
EST50HC8 50 47~52 650 2*11 478.22 769.93 1441.7 39.1 2*65
EST55HC8 55 52~57 650 2*11 523.5 842.83 1578.2 44.2 2.*80
EST60HC8 60 57~64.5 700 2*15 575.04 925.81 1733.6 49.5 2*80
EST70HC8 70 64.5~75 700 2*15 669.91 1078.55 2019.6 60 2*100

7.Eurostars Quotation Remarks-Air handling unit
1.Packing: Standard export package
2.Delivery Day: 20 working days after deposit is confirmed
3.Delivery term: CIF,FOB or CNF EX-Work are welcomed
4.Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
  Or 100% Irrevocable non-transferred LC at sight
5.Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
6.Validity: 20 days
7.Payment currency: USD
 
8.CERTIFICATE-- CE certificated

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier