Water Cooled Chiller Lab Industrial Precision Water Chiller Freezer Alcohol
1. Eurostars industrial chiller protection devices
(1)Motor overload protection
Including for compressor motors, water pump motors.
There are some situations that will cause damage to motors in an industrial chiller, such as instable voltage, ambient temperature too high which mostly caused by poor ventilation, returning water temperature too high, etc. In these cases the motor running current will get higher than its safe range, which might damage the motor if keep it working. Built in protection for overload will shut down the chiller and warn you if the motors are working unhealthily.
(2)Compressor motor overheat protection
Compressor is the heart of an industrial chiller, it reflects problem of the whole chiller unit. The situation causes compressor motor overheat includes poor ventilation, dusty condenser, refrigerant circuit blocking, lack of refrigerant, etc.
This alarm reminds you to check through the chiller unit, prevent it from burning out because of unhealthy working condition.
(3)Discharge temperature overhigh protection
Discharge temperature overhigh normally caused by high suction temperature, high compressor motor temperature, lack of refrigerant, etc. It works as supplementary of compressor motor overheat.
(4)High&low pressure protection
High pressure normally caused by poor ventilation, dusty condenser, refrigerant circuit blocking, etc.
Low temperature caused by lack of refrigerant, system blocking and so on.
(5)Returning water overheat protection
Chiller supply cold water to cool the production process, normally the returning water temperature will be 3ºC to 8ºC higher than supplied water. If the chiller is not creating cooling energy, or the chiller capacity is not enough for the application, the temperature in the circuit will get higher and higher. This will cause damage for the production even the equipment.
While a chiller got an alarm function for returning water temperature, we can learn the situation promptly and make reaction.
(6)Low water flow/level protection
For a chiller with no open-circuit water tank, there will be a water flow switch to make sure the water circuit is working, preventing both production process and chiller unit from harmed by circuit blocking or water leaking.
(7)Phase protection
If an industrial chiller was falsely wired, motors will revert, which is a serious problem for all the motors. Phase protection will remind you to connect the power in a right way.
(8)Anti-freezing protection
This function prevents the water in the circuit from freezing, so to make sure the cooling circuit working in a healthy condition.
2. Eurostars water cooled industrial chiller applications
In industries as diverse as plastics manufacturing, metals finishing, pharmaceutical and chemical processing and dry cleaning, Eurostars has provided innovative solutions to some of the most challenging industrial process cooling problems.
From chillers that comply with rigorous food processing industry regulations to high-quality extrusion bath recirculators, Eurostars industry solutions keep paces with the evolving requirements of your business.
Major Industries Served:
*Plastics: Injection Molding, Blow Molding, Extrusion
*Chemical & Petrochemical Process Systems
*Environmental test chambers
*Metal Anodizing
*Pharmaceutical
*Automotive: Plastics, Laser, Coolant
*Metal Working: Laser, Stamping, Welding, Hydroforming
*Paint Lines
*Bottling Plants
*All Chilled Water Applications
3. Eurostars water cooled water chiller main components
Compressor |
famous branded scroll, such as Copeland,Danfoss,Panosonic(Sanyo),Dakin |
Condenser |
Shell and tube type condenser |
Evaporator |
shell and tube type, plate type, coil in tank type |
Expansion valve |
Famous brands such as Danfoss, Emerson |
Controller |
leading brand PLC or SCM controller (touch screen display optional) |
Pump |
Leading brand chilled pump, such as CNP |
4.Factory testing of Eurostars every chiller unit
(1)Pressurization and helium leak detection of refrigeration circuit |
(2)Pressurization and leak testing of fluid circuit |
(3)Chiller performance and power consumption at full load |
(4)Proper operation of all controls, safety devices, and alarms |
(5)Electrical tests according to standards |
5. Eurostars water cooled industrial chiller brief technical data
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Water Cooled Chiller Unit |
Model ESSW- |
03ISCN |
04ISCN |
05ISCN |
06ISCN |
08IDCN |
10IDCN |
12IDCN |
Item NO. |
3 |
4 |
5 |
6 |
8 |
10 |
12 |
Rated Cooling Capacity |
KW |
10.15 |
12.93 |
16.13 |
20.40 |
25.00 |
32.26 |
40.80 |
USRT |
2.89 |
3.68 |
4.59 |
5.80 |
7.11 |
9.17 |
11.60 |
×1000 kcal/h |
8.73 |
11.12 |
13.87 |
17.54 |
21.50 |
27.74 |
35.09 |
Water Cooled Chiller Unit |
Model ESSW- |
15IDCN |
20IDCN |
25IDCN |
30IDCN |
40IQCN |
50IQCN |
60IQCN |
Item NO. |
15 |
20 |
25 |
30 |
40 |
50 |
60 |
Rated Cooling Capacity |
KW |
49.23 |
66.21 |
80.44 |
99.56 |
132.42 |
160.89 |
199.12 |
USRT |
14.00 |
18.83 |
22.87 |
28.31 |
37.65 |
45.75 |
56.62 |
×1000 kcal/h |
42.34 |
56.94 |
69.18 |
85.62 |
113.88 |
138.37 |
171.24 |
Remarks:
(1) Rated Cooling Capacity Based on:Evaporating temperature 7ºC;Condensing temperature 40ºC.
(2)Chilled Water Range: 5~25ºC;
(3)Cooling Water Range: 20~40ºC.
6. Industrial chiller refrigerant changes and water recirculation system
7. Eurostars Company Ceritifcate & Customer Visiting
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
(1)With more certificate
(2) Professional team with over more than 10 years industry knowledge
(3) Oversea installation.
(4) Customer-made accepted.
(5) Diamond member of Made-In-China
(6) Audited supplier by SGS
8. Our factory view
Modern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numerical control punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,. etc..
Chiller production at our previous location as below
9. Eurostars industrial chiller package and delivery
Our standard package is plastic film with plywood case for safe delivery and easy to load/unload.
10. Eurostars industrial chiller projects
We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..
11. Types of water chiller and the differences
As described, two different cooling mediums (air or water) can facilitate the transfer of the latent heat given up as the refrigerant changes from vapor to liquid. Thus, chillers can use two different types of condensers, air-cooled and water-cooled.
(1)Air-cooled condensers resemble the "radiators" that cool automobile engines. They use a motorized blower to force air across a grid of refrigerant lines. Unless they are specially designed for high-ambient conditions, air-cooled condensers require ambient temperatures of 95°F (35°C) or below to operate effectively.
(2)Water-cooled condensers perform the same function as air-cooled condensers, but require two steps to complete the heat transfer. First, heat moves from refrigerant vapor into the condenser water. Then, the warm condenser water is pumped to a cooling tower where the process heat is ultimately discharged to the atmosphere.
(3)Water-cooled chillers are typically intended for indoor installation and operation, and are cooled by a separate condenser water loop and connected to outdoor cooling towers to expel heat to the atmosphere.
(4)Air-cooled and evaporative cooled chillers are intended for outdoor installation and operation. Air-cooled chillers are directly cooled by ambient air being mechanically circulated directly through the machine's condenser coil to expel heat to the atmosphere.
12. Our technical support
(1)Before selling
*Set up customers file, and arrange professional sale engineers to introduce company products and services to customers in detail.
*If customers are interested in our products, we will send professional technicians to survey the installation environment.
*Make the solution according to different customers' requirements.
(2)During selling
*Machine installs and test by qualification engineers.
*Ensure all the products we provided are qualified and new. The working life of the main engine is more than 15 years.
*Construct and install the heat pump according to national relevant policies strictly, and ensure high quality delivery on time.
*Test and debug the equipments strictly to ensure the safety and stability.
*During the delivery, provide comprehensive and professional technical training on instructions and maintenance to customers.
(3)After selling
*We promise to offer free consulting call in 7×24 hours mode to solve the problems found in practice.
*Products guarantee is 18~24 months from ex-factory date. Within 18months,if any components of your products damaged because of quality, we supply new replacement for free.
*After the expiration of the quality assurance, we will continue to provide lifelong maintenance services, with just charging some cost price.