Horizontal Ceiling Exposed Fan Coil Unit With Return Air Bottom
1. Ceiling exposed floor standing fan coil variable styles
Four style universal fan coil unit can be selected:
Horizontal ceiling type with air return from downward without supporting legs |
Floor standing type with air return from front with supporting legs |
Horizontal ceiling type with air return from backward without supporting legs |
Floor standing type with air return from bottom with supporting legs |
Product Type |
Ceiling exposed or floor standing Fan Coil Unit |
Motor |
AC (DC as optional) |
Pipe System |
2 pipes or 4 pipes |
Cooling Capacity |
1.8KW ~ 12.6KW (2 pipe system) |
Heating Capacity |
2.7KW ~ 18.9KW (2 pipe system) |
Cooling Capacity |
1.8KW ~ 12.6KW (4 pipe system) |
Heating Capacity |
1.3KW ~ 9.07W (4 pipe system) |
![Horizontal Ceiling Exposed Fan Coil Unit with Return Air Bottom](//www.micstatic.com/athena/img/transparent.png)
2. Ceiling exposed fan coil unit main components
(1) Fan
(2) Motor
(3) Drain pan
(4) Water coil
(5)Casing
(6)Return air plenum and filter
![Horizontal Ceiling Exposed Fan Coil Unit with Return Air Bottom](//www.micstatic.com/athena/img/transparent.png)
3. Ceiling exposed floor standing fan coil configuration
4. Eurostars Fan coil unit series
1 |
Ceiling concealed fan coil unit |
2 |
High ESP ducted fan coil unit |
3 |
Universal concealed fan coil unit |
4 |
Floor standing exposed fan coil unit |
5 |
Ultra thin exposed fan coil unit |
6 |
Ceiling exposed fan coil unit |
7 |
Ceiling cassette fan coil unit |
8 |
Ceiling exposed & floor standing fan coil unit |
9 |
Wall mounted fan coil unit |
5. Ceiling floor standing exposed fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Universal Exposed Fan Coil Unit(2 pipe system) |
Model EST |
200HE2 |
300HE2 |
400HE2 |
500HE2 |
600HE2 |
800HE2 |
1000HE2 |
1200HE2 |
1400HE2 |
200VE2 |
300VE2 |
400VE2 |
500VE2 |
600VE2 |
800VE2 |
1000VE2 |
1200VE2 |
1400VE2 |
Power supply |
220V/1PH/50HZ |
Air flow
(m3/h) |
H |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
M |
260 |
390 |
510 |
640 |
770 |
1020 |
1280 |
1530 |
1790 |
L |
170 |
260 |
340 |
430 |
510 |
680 |
850 |
1020 |
1190 |
Cooling capacity |
TH |
H |
W |
1800 |
2700 |
3600 |
4500 |
5400 |
7200 |
9000 |
10800 |
12600 |
SH |
W |
1368 |
2052 |
2736 |
3420 |
4103 |
5471 |
6839 |
8207 |
9575 |
TH |
M |
W |
1494 |
2242 |
2989 |
3736 |
4483 |
5978 |
7472 |
8967 |
10461 |
SH |
W |
1181 |
1771 |
2362 |
2952 |
3541 |
4722 |
5903 |
7084 |
8265 |
TH |
L |
W |
1162 |
1744 |
2325 |
2906 |
3487 |
4649 |
5812 |
6974 |
8136 |
SH |
W |
953 |
1430 |
1907 |
2383 |
2860 |
3813 |
4765 |
5718 |
6672 |
Heating capacity |
H |
W |
2700 |
4050 |
5400 |
6750 |
8100 |
10800 |
13500 |
16200 |
18900 |
M |
W |
2131 |
3197 |
4262 |
5328 |
6393 |
8524 |
10655 |
12786 |
14917 |
L |
W |
1675 |
2511 |
3349 |
4186 |
5024 |
6697 |
8372 |
10046 |
11721 |
Universal Exposed Fan Coil Unit(4 pipe system) |
Model EST |
200HE4 |
300HE4 |
400HE4 |
500HE4 |
600HE4 |
800HE4 |
1000HE4 |
1200HE4 |
1400HE4 |
200VE4 |
300VE4 |
400VE4 |
500VE4 |
600VE4 |
800VE4 |
1000VE4 |
1200VE4 |
1400VE4 |
Power supply |
220V/1PH/50HZ |
Air flow
(m3/h) |
H |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
M |
260 |
390 |
510 |
640 |
770 |
1020 |
1280 |
1530 |
1790 |
L |
170 |
260 |
340 |
430 |
510 |
680 |
850 |
1020 |
1190 |
Cooling capacity |
TH |
H |
W |
1800 |
2700 |
3600 |
4500 |
5400 |
7200 |
9000 |
10800 |
12600 |
SH |
W |
1368 |
2052 |
2736 |
3420 |
4103 |
5471 |
6839 |
8207 |
9575 |
TH |
M |
W |
1494 |
2242 |
2989 |
3736 |
4483 |
5978 |
7472 |
8967 |
10461 |
SH |
W |
1181 |
1771 |
2362 |
2952 |
3541 |
4722 |
5903 |
7084 |
8265 |
TH |
L |
W |
1162 |
1744 |
2325 |
2906 |
3487 |
4649 |
5812 |
6974 |
8136 |
SH |
W |
953 |
1430 |
1907 |
2383 |
2860 |
3813 |
4765 |
5718 |
6672 |
Heating capacity |
H |
W |
1300 |
1940 |
2590 |
3240 |
3890 |
5180 |
6480 |
7780 |
9070 |
M |
W |
1020 |
1530 |
2040 |
2550 |
3060 |
4070 |
5090 |
6110 |
7130 |
L |
W |
820 |
1230 |
1630 |
2040 |
2450 |
3270 |
4080 |
4900 |
5720 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
6.Why choose EUROSTARS?
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Webiste 1: http://eurostarschiller.en.made-in-china.com/
Website 2: http://eurostarschiller.en.made-in-china.com/
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
![Horizontal Ceiling Exposed Fan Coil Unit with Return Air Bottom](//www.micstatic.com/athena/img/transparent.png)
7. FAQ
Q: Can I have a sample for testing before ordering products?
A: Yes, you can. And you are warmly welcomed to visit our factory before PO.
Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
Q: How to properly install the fan coil unit?
A: We have very detailed user manual and installation instructions, also can be directly telephone or online video guidance.
8. Our fan coil production line
Every fan coil has strict production process, including assembly, testing, packing.
![Horizontal Ceiling Exposed Fan Coil Unit with Return Air Bottom](//www.micstatic.com/athena/img/transparent.png)
![Horizontal Ceiling Exposed Fan Coil Unit with Return Air Bottom](//www.micstatic.com/athena/img/transparent.png)
9. Our service and Customer visit
Pre-Sales Service
(1) Inquiry and consulting support.
(2) Sample testing support.
(3) View our Factory.
After-Sales Service
(1)Provide customers with installation and commissioning online instructions. And we also provide local whole project installation.
(2) Well-trained engineers available to overseas service.
(3) Worldwide agents and after-sale service available.
10. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
![Horizontal Ceiling Exposed Fan Coil Unit with Return Air Bottom](//www.micstatic.com/athena/img/transparent.png)
![Horizontal Ceiling Exposed Fan Coil Unit with Return Air Bottom](//www.micstatic.com/athena/img/transparent.png)
11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..
![Horizontal Ceiling Exposed Fan Coil Unit with Return Air Bottom](//www.micstatic.com/athena/img/transparent.png)