Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit
1. Ceiling mounted floor standing fan coil brief introduction
Fan coil unit is mainly composed of heat exchanger, motor, fan, water coil, shell and infrared remote controller.It is suitable for the centralized air conditioning system. Through heat exchanger, the fan coil unit provides cold/hot air to adjust the temperature. It can be used for hotel, department, restaurant, hospital, office building and etc.
Product Type |
Ceiling, Wall mounted or floor standing Fan Coil Unit |
Motor |
AC |
Pipe System |
2 pipes or 4 pipes |
Cooling Capacity |
2.7KW ~ 12.6KW (2 pipe system) |
Heating Capacity |
4.05KW ~ 18.9KW (2 pipe system) |
Cooling Capacity |
2.025KW ~ 9.45KW (4 pipe system) |
Heating Capacity |
1.62KW ~ 7.56KW (4 pipe system) |
2. Ceiling mounted floor standing fan coil unit main components
(1) Fan
Fans are centrifugal type. All fans are statically and dynamically balanced.
(2) Motor
Single-phase motors are suitable for different voltages, such as 110V, 115V, 120V, 220V, 230V, 240V. All motors have 10 percent voltage utilization range and wired to unit terminal box. Motors are designed for long life.
(3) Casing
Casing are constructed of heavy gauge steel. Air grille is ABS material that easily to open for maintenance.
(4) Heat exchanger
Coils are standard design together with rows. High efficient hydrophilic aluminum fins are mechanically bonded to seamless copper tubes. All coils are specifically designed and circuited for water use. All coils are tested at 3.3MPa.
(5) Drained pan
The condensate water should be drained out to ensure the fan coil unit safety running. The fan coil unit shall be factory installed return air plenum that encloses the fan section of the unit. No field fabrication is required. The return air arrangement is from front of the fan coil.
(6) Washable filter
Filter is easy to pull out and washable.
(7)Remote controller
Comfortable and intuitive, with a minimal and ergonomic design. Remote controller with LED display shows the set-up of the unit: room temperature, fan speed and running mode, etc.
3. Ceiling mounted exposed floor standing fan coil features
(1) Excellent performance
Air flow capacities from 300 to 1400 CFM, 2-pipe or 4-pipe system combinations, economical, 3-speed fans deliver the right amount of conditioned air for comfort needs at any load.
(2) High reliability
Coils are factory leak tested at 3.3MPa air pressure with coil submerged in water. Base units are CE certified for European standards. Unit casing meets requirements for flame and smoke generation.
(3) Easy maintenance
Removable panels make access to components and connections easy. Cleanable filters available.
Label information adhered to each unit includes model, cooling capacity, electrical information.
(4) Simple installation
Piping, drain and wiring connections are readily accessible. Predrilled mounting holes and slots.
Compact unit casing accommodates installation in reduced ceiling plenum space.
4. Eurostars Fan coil unit series
1 |
Ceiling concealed fan coil unit |
2 |
High ESP ducted fan coil unit |
3 |
Universal concealed fan coil unit |
4 |
Floor standing exposed fan coil unit |
5 |
Ultra thin exposed fan coil unit |
6 |
Ceiling exposed fan coil unit |
7 |
Ceiling cassette fan coil unit |
8 |
Ceiling exposed & floor standing fan coil unit |
9 |
Wall mounted fan coil unit |
5. Ceiling mounted floor standing exposed fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Ceiling Exposed/Floor Mounted Fan Coil Unit (2 pipe system) |
Model EST~ |
300CF2 |
400CF2 |
500CF2 |
600CF2 |
800CF2 |
1000CF2 |
1200CF2 |
1400CF2 |
Air flow
(m3/h) |
High |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
Medium |
420 |
560 |
770 |
910 |
1210 |
1450 |
1850 |
2150 |
Low |
340 |
480 |
610 |
820 |
1100 |
1380 |
1600 |
2000 |
Cooling capacity |
TH |
H |
W |
2700 |
3600 |
4500 |
5400 |
7200 |
9000 |
10800 |
12600 |
BTU |
9215 |
12287 |
15359 |
18430 |
24574 |
30717 |
36860 |
43004 |
SH |
W |
1990 |
2730 |
3174 |
4261 |
5385 |
6746 |
8109 |
9062 |
BTU |
6792 |
9317 |
10833 |
14543 |
18379 |
23024 |
27676 |
30929 |
TH |
M |
W |
2485 |
3030 |
3752 |
4467 |
6499 |
7926 |
9389 |
10605 |
BTU |
8481 |
10341 |
12806 |
15246 |
22181 |
27051 |
32045 |
36195 |
SH |
W |
1570 |
2015 |
2450 |
3070 |
4278 |
5447 |
6669 |
7262 |
BTU |
5358 |
6877 |
8362 |
10478 |
14601 |
18591 |
22761 |
24785 |
TH |
L |
W |
2078 |
2504 |
2950 |
3831 |
5660 |
7295 |
8619 |
8989 |
BTU |
7092 |
8546 |
10068 |
13075 |
19318 |
24898 |
29417 |
30679 |
SH |
W |
1212 |
1545 |
1844 |
2397 |
3317 |
4460 |
5300 |
5555 |
BTU |
4137 |
5273 |
6294 |
8181 |
11321 |
15222 |
18089 |
18959 |
Heating capacity |
H |
W |
4050 |
5400 |
6750 |
8100 |
10800 |
13500 |
16200 |
18900 |
BTU/h |
13823 |
18430 |
23038 |
27645 |
36860 |
46076 |
55291 |
64506 |
M |
W |
2792 |
3970 |
4941 |
5740 |
7987 |
10557 |
13101 |
14011 |
BTU/h |
9529 |
13550 |
16864 |
19591 |
27260 |
36031 |
44714 |
47820 |
L |
W |
1788 |
2800 |
3533 |
3907 |
5464 |
7048 |
8714 |
9778 |
BTU/h |
6102 |
9556 |
12058 |
13335 |
18649 |
24055 |
29741 |
33372 |
Ceiling Exposed/Floor Mounted Fan Coil Unit (4 pipe system) |
Model EST~ |
300CF4 |
400CF4 |
500CF4 |
600CF4 |
800CF4 |
1000CF4 |
1200CF4 |
1400CF4 |
Air flow
(m3/h) |
High |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
Medium |
420 |
560 |
770 |
910 |
1210 |
1450 |
1850 |
2150 |
Low |
340 |
480 |
610 |
820 |
1100 |
1380 |
1600 |
2000 |
Cooling capacity |
TH |
H |
W |
2025 |
2700 |
3375 |
4050 |
5400 |
6750 |
8100 |
9450 |
BTU |
6911 |
9215 |
11519 |
13823 |
18430 |
23038 |
27645 |
32253 |
SH |
W |
1532 |
2102 |
2445 |
3281 |
4146 |
5194 |
6245 |
6978 |
BTU |
5229 |
7174 |
8345 |
11198 |
14150 |
17727 |
21314 |
23816 |
TH |
M |
W |
1864 |
2273 |
2814 |
3350 |
4874 |
5945 |
7042 |
7954 |
BTU |
6362 |
7758 |
9604 |
11434 |
16635 |
20290 |
24034 |
27147 |
SH |
W |
1210 |
1552 |
1887 |
2365 |
3295 |
4195 |
5135 |
5592 |
BTU |
4130 |
5297 |
6440 |
8072 |
11246 |
14318 |
17526 |
19085 |
TH |
L |
W |
1559 |
1878 |
2213 |
2873 |
4245 |
5470 |
6465 |
6742 |
BTU |
5321 |
6410 |
7553 |
9806 |
14488 |
18669 |
22065 |
23010 |
SH |
W |
933 |
1190 |
1420 |
1845 |
2555 |
3435 |
4081 |
4277 |
BTU |
3184 |
4061 |
4846 |
6297 |
8720 |
11724 |
13928 |
14597 |
Heating capacity |
H |
W |
1620 |
2160 |
2701 |
3240 |
4320 |
5400 |
6480 |
7560 |
BTU/h |
5529 |
7372 |
9219 |
11058 |
14744 |
18430 |
22116 |
25802 |
M |
W |
1115 |
1588 |
1976 |
2296 |
3195 |
4223 |
5240 |
5604 |
BTU/h |
3805 |
5420 |
6744 |
7836 |
10905 |
14413 |
17884 |
19126 |
L |
W |
715 |
1120 |
1413 |
1563 |
2186 |
2819 |
3486 |
3911 |
BTU/h |
2440 |
3823 |
4823 |
5335 |
7461 |
9621 |
11898 |
13348 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
6. Ceiling floor fan coil unit construction parts
7. About EUROSTARS?
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
(1)With more certificate
(2) Professional team with over more than 10 years industry knowledge
(3) Oversea installation.
(4) Customer-made accepted.
(5) Diamond member of Made-In-China
(6) Audited supplier by SGS
8. Our fan coil production line
Every fan coil has strict production process, including assembly, testing, packing.
9. Our service and Customer visit
Pre-Sales Service
(1) Inquiry and consulting support.
(2) Sample testing support.
(3) View our Factory.
After-Sales Service
(1)Provide customers with installation and commissioning online instructions. And we also provide local whole project installation.
(2) Well-trained engineers available to overseas service.
(3) Worldwide agents and after-sale service available.
10. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..