  • Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit
  • Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit
  • Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit
  • Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit
  • Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit
  • Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit
Find Similar Products

Basic Info.

Model NO.
EST-CF Series
Corrosion Durability
Higher
Operating Voltage
110V/220~240V-50Hz/60Hz-1pH
Noise Level
Low
Application Fields
Restaurant/Hotel Room/Meeting Room/Office
Mounting
Ceiling Mounted, Floor Standing
Lifetime
>20 years
Certification
CE
Condition
New
Motor
AC Motor
Pipe System
Two Pipe, Four Pipe System
Main Usage
Chiller, Heat Pump, Underfloor Heating
Controller
Infrared Remote Controller, Wiire Controller
Production Time
20 Days for Bulk Order
Installation
Wall Mounted /Floor Standing
Air Return
From Front
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Trademark
ESACIR
Origin
Guangdong, Prc.
HS Code
8415830000
Production Capacity
10000 PCS/Year

Product Description

Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit

1. Ceiling mounted floor standing fan coil brief introduction
Fan coil unit is mainly composed of heat exchanger, motor, fan, water coil, shell and infrared remote controller.It is suitable for the centralized air conditioning system. Through heat exchanger, the fan coil unit provides cold/hot air to adjust the temperature. It can be used for hotel, department, restaurant, hospital, office building and etc.
Product Type Ceiling, Wall mounted or floor standing Fan Coil Unit
Motor AC
Pipe System 2 pipes or 4 pipes 
Cooling Capacity 2.7KW ~ 12.6KW (2 pipe system)
Heating Capacity 4.05KW ~ 18.9KW (2 pipe system)
Cooling Capacity 2.025KW ~ 9.45KW (4 pipe system)
Heating Capacity 1.62KW ~ 7.56KW (4 pipe system)

2. Ceiling mounted floor standing fan coil unit main components
(1) Fan 

Fans are centrifugal type. All fans are statically and dynamically balanced.
(2) Motor
Single-phase motors are suitable for different voltages, such as 110V, 115V, 120V, 220V, 230V, 240V. All motors have 10 percent voltage utilization range and wired to unit terminal box. Motors are designed for long life.
(3) Casing
Casing are constructed of heavy gauge steel. Air grille is ABS material that easily to open for maintenance.
(4) Heat exchanger
Coils are standard design together with rows. High efficient hydrophilic aluminum fins are mechanically bonded to seamless copper tubes. All coils are specifically designed and circuited for water use. All coils are tested at 3.3MPa.
(5) Drained pan
The condensate water should be drained out to ensure the fan coil unit safety running. The fan coil unit shall be factory installed return air plenum that encloses the fan section of the unit. No field fabrication is required. The return air arrangement is from front of the fan coil.
(6) Washable filter
Filter is easy to pull out and washable.
(7)Remote controller
Comfortable and intuitive, with a minimal and ergonomic design. Remote controller with LED display shows the set-up of the unit: room temperature, fan speed and running mode, etc.


Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit

3. Ceiling mounted exposed floor standing fan coil features
(1) Excellent performance
Air flow capacities from 300 to 1400 CFM, 2-pipe or 4-pipe system combinations, economical, 3-speed fans deliver the right amount of conditioned air for comfort needs at any load.
(2) High reliability
Coils are factory leak tested at 3.3MPa air pressure with coil submerged in water. Base units are CE certified for European standards. Unit casing meets requirements for flame and smoke generation.
(3) Easy maintenance
Removable panels make access to components and connections easy. Cleanable filters available.
Label information adhered to each unit includes model, cooling capacity, electrical information.
(4) Simple installation
Piping, drain and wiring connections are readily accessible. Predrilled mounting holes and slots.
Compact unit casing accommodates installation in reduced ceiling plenum space.

 
4. Eurostars Fan coil unit series
Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit
1 Ceiling concealed fan coil unit
2 High ESP ducted fan coil unit
3 Universal concealed fan coil unit
4 Floor standing exposed fan coil unit
5 Ultra thin exposed fan coil unit
6 Ceiling exposed fan coil unit
7 Ceiling cassette fan coil unit
8 Ceiling exposed & floor standing fan coil unit
9 Wall mounted fan coil unit

5. Ceiling mounted floor standing exposed fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Ceiling Exposed/Floor Mounted Fan Coil Unit (2 pipe system)
Model EST~ 300CF2 400CF2 500CF2 600CF2 800CF2 1000CF2 1200CF2 1400CF2
Air flow
 (m3/h)
High  510 680 850 1020 1360 1700 2040 2380
Medium 420 560 770 910 1210 1450 1850 2150
Low  340 480 610 820 1100 1380 1600 2000
Cooling capacity TH H W 2700 3600 4500 5400 7200 9000 10800 12600
BTU 9215 12287 15359 18430 24574 30717 36860 43004
SH W 1990 2730 3174 4261 5385 6746 8109 9062
BTU 6792 9317 10833 14543 18379 23024 27676 30929
TH M W 2485 3030 3752 4467 6499 7926 9389 10605
BTU 8481 10341 12806 15246 22181 27051 32045 36195
SH W 1570 2015 2450 3070 4278 5447 6669 7262
BTU 5358 6877 8362 10478 14601 18591 22761 24785
TH L W 2078 2504 2950 3831 5660 7295 8619 8989
BTU 7092 8546 10068 13075 19318 24898 29417 30679
SH W 1212 1545 1844 2397 3317 4460 5300 5555
BTU 4137 5273 6294 8181 11321 15222 18089 18959
Heating capacity H W 4050 5400 6750 8100 10800 13500 16200 18900
BTU/h 13823  18430  23038  27645  36860  46076  55291  64506 
M W 2792 3970 4941 5740 7987 10557 13101 14011
BTU/h 9529  13550  16864  19591  27260  36031  44714  47820 
L W 1788 2800 3533 3907 5464 7048 8714 9778
BTU/h 6102  9556  12058  13335  18649  24055  29741  33372 
Ceiling Exposed/Floor Mounted Fan Coil Unit (4 pipe system)
Model EST~ 300CF4 400CF4 500CF4 600CF4 800CF4 1000CF4 1200CF4 1400CF4
Air flow
 (m3/h)
High  510 680 850 1020 1360 1700 2040 2380
Medium 420 560 770 910 1210 1450 1850 2150
Low  340 480 610 820 1100 1380 1600 2000
Cooling capacity TH H W 2025 2700 3375 4050 5400 6750 8100 9450
BTU 6911 9215 11519 13823 18430 23038 27645 32253
 SH W 1532 2102 2445 3281 4146 5194 6245 6978
BTU 5229 7174 8345 11198 14150 17727 21314 23816
TH M W 1864 2273 2814 3350 4874 5945 7042 7954
BTU 6362 7758 9604 11434 16635 20290 24034 27147
SH W 1210 1552 1887 2365 3295 4195 5135 5592
BTU 4130 5297 6440 8072 11246 14318 17526 19085
TH L W 1559 1878 2213 2873 4245 5470 6465 6742
BTU 5321 6410 7553 9806 14488 18669 22065 23010
SH W 933 1190 1420 1845 2555 3435 4081 4277
BTU 3184 4061 4846 6297 8720 11724 13928 14597
Heating capacity H W 1620 2160 2701 3240 4320 5400 6480 7560
BTU/h 5529  7372  9219  11058  14744  18430  22116  25802 
M W 1115 1588 1976 2296 3195 4223 5240 5604
BTU/h 3805  5420  6744  7836  10905  14413  17884  19126 
L W 715 1120 1413 1563 2186 2819 3486 3911
BTU/h 2440  3823  4823  5335  7461  9621  11898  13348 

Remarks:
(1)  Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)  Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature  60°C/50ºC.

6. Ceiling floor fan coil unit construction parts
Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit

 
7. About EUROSTARS?  
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
(1)With more certificate
(2) Professional team with over more than 10 years industry knowledge
(3) Oversea installation.
(4) Customer-made accepted.
(5) Diamond member of Made-In-China
(6) Audited supplier by SGS

Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit

8. Our fan coil production line
Every fan coil has strict production process, including assembly, testing, packing.

Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit
Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit

9. Our service and Customer visit
Pre-Sales Service
(1) Inquiry and consulting support.
(2) Sample testing support.
(3) View our Factory.
After-Sales Service
(1)Provide customers with installation and commissioning online instructions. And we also provide local whole project installation.
(2) Well-trained engineers available to overseas service.
(3) Worldwide agents and after-sale service available.

Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit
Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit

 
10. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit
Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit
11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..
Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit

Heat Pump Fan Coil Wall Mounted Exposed Fan Coil Unit

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier