Concealed Fan Coil Duct Installation for Central Air Conditioning System

Type: Fan Coil Unit
Air Tube Material: Galvanized Sheet
Corrosion Durability: Higher
Operating Voltage: 110V/220~240V-50Hz/60Hz-1pH
Noise Level: Low
Application Fields: Restaurant/Hotel Room
Samples:
US$ 195/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
EST series
Mounting
Ceiling Concealed
Lifetime
>20 years
Certification
CE
Condition
New
Motor
AC or DC
Rows
3 Rows or 4 Rows
Main Usage
Chiller, Heat Pump, Underfloor Heating
Air Return
Backward/Downward
Production Time
20 Days for Bulk Order
Pipe System
Two Pipe and Four Pipe System
Air Outlet Static Pressure
0, 12, 30, 50PA
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Trademark
ESACIR
Origin
Guangdong, Prc.
HS Code
8415830000
Production Capacity
10000 PCS/Year

Product Description

Concealed Fan Coil Duct Installation For Central Air Conditioning System 

1. Ceiling concealed fan coil brief description
Fan coil units are mainly composed of centrifugal fans and coil heat exchangers. It is the terminal device of the central air conditioning system. And the fan sends indoor air or outdoor mixed air through the air cooler to be cooled or heated and then sends the air into the room to lower or raise the indoor temperature to meet people's comfort requirements.
It is widely used in hotels, restaurants, factories, hospitals, exhibition gall eries, shopping malls and moving buildings.It is used to meet the requirements of cooling, dehumidification, heating and so on.

 
2. Fan coil unit series
Concealed Fan Coil Duct Installation for Central Air Conditioning System

Ceiling concealed fan coil unit
High ESP ducted fan coil unit
Universal concealed fan coil unit
Floor standing exposed fan coil unit
Ultra thin exposed fan coil unit
Ceiling exposed fan coil unit
Ceiling cassette fan coil unit
Ceiling exposed & floor standing fan coil unit
Wall mounted fan coil unit

3. Ceiling concealed fan coil unit main components
(1) Fan 
Fans are double inlets multi-blade centrifugal type. All fans are statically and dynamically balanced.
(2) Motor
Single-phase motors are suitable for different voltages, such as 110V, 115V, 120V, 220V, 230V, 240V. All motors have 10 percent voltage utilization range and wired to unit terminal box. Motors are designed for long life.
(3) Drain pan
Dray pan is integrally attached to coil casings and ended with drain hose. All pans are galvanized for corrosion resistance and cover the entire coil.
(4) Water coil
Coils are 3-row as standard design together with 4-row design as option. High efficient hydrophilic aluminum fins are mechanically bonded to seamless copper tubes. All coils are specifically designed and circuited for water use. All coils are tested at 3.3MPa.
(5) Casing
Casing are constructed of heavy gauge steel. Interior surface of unit panels are acoustically and thermally insulated with polyethylene foam.
Units are furnished as standard with a 1 inch duct collar to facilitate connection of the supply air duct.
(6) Return air plenum (optional)
The fan coil unit shall be factory installed return air plenum that encloses the fan section of the unit. No field fabrication is required. The return air arrangement is adaptable between bottom or rear return of the plenum.
(7) Washable filter (optional)
Filter should be accessible from return air grille.


Concealed Fan Coil Duct Installation for Central Air Conditioning System

4. Ceiling horizontal concealed fan coil unit technical specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com

Horizontal Concealed Fan Coil Unit (2 pipe system)
Model EST~ 200HC2 300HC2 400HC2 500HC2 600HC2 800HC2 1000HC2 1200HC2 1400HC2
Air flow (m3/h)
(0/12Pa,30Pa Static Pressure)
High  340 510 680 850 1020 1360 1700 2040 2380
Medium  270 380 515 660 765 1040 1280 1550 1800
Low  190 260 340 430 530 710 860 1050 1280
Rated cooling capacity  H TH(W) 1800 2700 3600 4500 5400 7200 9000 10800 12600
SH(W) 1341 2012 2682 3353 4023 5364 6705 8046 9387
M TH(W) 1485 2187 2916 3645 4374 5832 7290 8748 10206
SH(W) 1152 1728 2304 2880 3455 4607 5759 6911 8063
L TH(W) 1134 1701 2268 2835 3402 4536 5670 6804 7938
SH(W) 930 1395 1860 2325 2790 3720 4649 5579 6509
Rated heating capacity  H W 2700 4050 5400 6750 8100 10800 13500 16200 18900
M 2079 3119 4158 5198 6237 8316 10395 12474 14553
L 1634 2450 3267 4084 4901 6534 8168 9801 11435
Horizontal Concealed Fan Coil Unit (2 pipe system 4 rows)
Model EST~ 200HC2 300HC2 400HC2 500HC2 600HC2 800HC2 1000HC2 1200HC2 1400HC2
Air flow (m3/h)
(0/12Pa,30Pa,45Pa
Static Pressure)
High  340 510 680 850 1020 1360 1700 2040 2380
Medium  270 380 515 660 765 1040 1280 1550 1800
Low  190 260 340 430 530 710 860 1050 1280
Rated cooling capacity  H TH(W) 2000 2950 3950 4950 5950 7900 9900 11900 13850
SH(W) 1375 2062 2749 3437 4124 5498 6873 8247 9622
M TH(W) 1560 2340 3120 3900 4680 6240 7800 9360 10920
SH(W) 1232 1849 2465 3081 3697 4930 6162 7394 8627
L TH(W) 1213 1820 2427 3033 3640 4854 6067 7280 8494
SH(W) 995 1492 1990 2487 2985 3980 4975 5970 6965
Rated heating capacity  H W 2950 4450 5950 7450 8900 11900 14850 17800 20800
M 2256 3383 4511 5639 6768 9023 11279 13534 15790
L 1773 2658 3545 4431 5317 7089 8862 10634 12407
Horizontal Concealed Fan Coil Unit (4 pipe system)
Model EST~ 200HC4 300HC4 400HC4 500HC4 600HC4 800HC4 1000HC4 1200HC4 1400HC4
Air flow (m3/h)
(0/12Pa,30Pa Static Pressure)
High  340 510 680 850 1020 1360 1700 2040 2380
Medium  270 380 515 660 765 1040 1280 1550 1800
Low  190 260 340 430 530 710 860 1050 1280
Rated cooling capacity  H TH(W) 1800 2700 3600 4500 5400 7200 9000 10800 12600
SH(W) 1341 2012 2682 3353 4023 5364 6705 8046 9387
M TH(W) 1485 2187 2916 3645 4374 5832 7290 8748 10206
SH(W) 1152 1728 2304 2880 3455 4607 5759 6911 8063
L TH(W) 1134 1701 2268 2835 3402 4536 5670 6804 7938
SH(W) 930 1395 1860 2325 2790 3720 4649 5579 6509
Rated heating capacity  H W 1080 1620 2160 2700 3240 4320 5400 6480 7560
M 832 1248 1663 2079 2495 3326 4158 4990 5821
L 654 980 1307 1634 1960 2614 3267 3920 4574
Remarks:
(1)  Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)  Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature  60°C/50ºC.

5. Ceiling concealed fan coil unit features
(1) Excellent performance
(2) High reliability
(3) Easy maintenance
(4) Simple installation

 
6.Why choose EUROSTARS?  
1) With more certificate
2) Professional team with over more than 10 years industry knowledge
3) Oversea installation.
4) Customer-made accepted.
5) Diamond member of Made-In-China
6) Audited supplier by SGS

Concealed Fan Coil Duct Installation for Central Air Conditioning System
Concealed Fan Coil Duct Installation for Central Air Conditioning System

7. Our fan coil production line

Every fan coil has strict production process, including assembly, testing, packing.
Concealed Fan Coil Duct Installation for Central Air Conditioning System
Concealed Fan Coil Duct Installation for Central Air Conditioning System

8. Our service
Considerate after-sales service & product maintenance.You can contact us at any time.
Economical and energy-saving design scheme
Overseas engineer services
Integrated quality and profession R&D team
OEM/ODM available

 
9. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
Concealed Fan Coil Duct Installation for Central Air Conditioning System

10. Ceiling concealed fan coil installation instruction
(1) Air duct must be fireproof regulations for buildings.
(2) For horizontal air supply, N≥150 MM; if air duct is longer than 1 m, N≥200 mm.
(3) Size of M depends on air duct installation. Pressure loss of circulatory air must be consistent with outlet static pressure of the unit.
Concealed Fan Coil Duct Installation for Central Air Conditioning System

11. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..