Ce Certifcated Low Ambient Temp. Cooling and Heating Air Cooled Chiller

Product Details
Customization: Available
Heat Temperature: 50-70°C
Work Environment: Common Heat Pump
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
Find Similar Products

Basic Info.

Model NO.
ESGA series
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE
Heat Pump Compresor
Taiwan Hanbell
Heat Pump Expansion Valve
Emerson
Heat Pump Dry Filter
Danfoss
Transport Package
Standard Export Package
Specification
CE
Trademark
Eurostars
Origin
Guangdong, Prc
HS Code
8418692090
Production Capacity
800PCS/Year

Product Description

1.Unit Features-Eurostars air cooled air source heat pump
1).Heating capacity ranged from 130Kw to 790 Kw.
2). Adopt good quality famous brand Hanbell screw compressor,high efficiency, low noise, less wearing and long life
3).Both Evaporator and Condenser are high quality and high efficiency
4). World famous brand parts: such Emerson expansion valve, FUJI contactor other brand like PUNP, Schneider.
5). Can be widely used in different area,such as Massage center, Hospital, Hotel, School, etc 
6). Strong unit base frame ensured the equipment stable operation 
7). Adopt leading brand PLC or SCM controller
8). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.
 
2.Unit main parts photos and brand-Eurostars air cooled air source heat pump
Ce Certifcated Low Ambient Temp. Cooling and Heating Air Cooled Chiller
3.Technical parameter-air cooled air source heat pump



Refrigerant-R407C
Model     ESGA- 30SHTN 40SHTN 55SHTN 65SHTN 75SHTN 85SHTN 90SHTN
Rated Cooling Capacity Cooling Capacity (KW) 111 161 215 254 294 321 346
 Cooling Capacity (USRT) 31.57  45.79  61.15  72.24  83.62  91.30  98.41 
Comp. Input Power (KW) 34.6 48.2 63.8 70.5 82.4 90.2 98.9
Rated Heating Capacity Heating Capacity (KW) 122 174 232 269 311 341 369
Heating Capacity (USRT) 34.70  49.49  65.98  76.51  88.45  96.99  104.95 
Comp. Input Power (KW) 34.1  47.4  62.8  69.2  80.8  88.4  97.2 
Refrigerant  R407C
Power Supply  3φ-380V/50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection, 
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit 1
Capacity Control (%) 0, 66, 100 0, 50, 75, 100
Refrigerant Charge (Kg) 30 42 56 68 78 84 93
Air Cooled Heat Exchanger Ripple Aluminum Fins Around Copper Pipe
Water Cooled 
Heat Exchanger
Dia.of Pipe (inch) 2-1/2" 3" 3" 3" 4" 4" 4"
Water Side Max Pressure  (MPa) 1
Chilled  Water Flow(m3/h) 19.09  27.69  36.98  43.69  50.57  55.21  59.51 
Water Pressure Drop (kPa)  28 33 48 55 61 64 66
Flow of Hot Water(m3/h) 20.98  29.93  39.90  46.27  53.49  58.65  63.47 
Axial Fan Air Flow×1000m3/h 56.8 80.4 85.2 120.6 120.6 160.8 160.8
Power×Qty (KW) 1.2×4 2.0×4 1.2×8 1.2×8 1.2×8 2.0×8 2.0×8

Model     ESGA- 100DHTN 110DHTN 130DHTN 140DHTN 150DHTN 165DHTN 180DHTN
Rated Cooling Capacity Cooling Capacity (KW) 392 439 509 537 588 642 693
 Cooling Capacity (USRT) 111.49  124.86  144.77  152.73  167.24  182.59  197.10 
Comp. Input Power (KW) 116.4 127.6 141.0 148.2 164.8 180.4 197.8
Rated Heating Capacity Heating Capacity (KW) 424 464 538 568 624 682 740
Heating Capacity (USRT) 120.59  131.97  153.01  161.55  177.47  193.97  210.47 
Comp. Input Power (KW) 114.4  125.6 138.3  145.4  161.7  176.9  194.4
Refrigerant  R407C
Power Supply  3φ-380V-50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection,
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit 2
Capacity Control (%) 0, 25, 37.5, 50, 62.5, 75, 87.5, 100
Refrigerant Charge (Kg) 114 122 146 150 164 178 196
Air Cooled Heat Exchanger Ripple Aluminum Fins Around Copper Pipe
Water Cooled 
Heat Exchanger
Dia.of Pipe (inch) 5" 5" 3"×2 3"×2 4"×2 4"×2 4"×2
Water Side Max Pressure  (MPa) 1
Chilled  Water Flow(m3/h) 67.42  75.51  87.55  92.36  101.14  110.42  119.20 
Water Pressure Drop (kPa)  42 54 44 52 54 55 65
Flow of Hot Water(m3/h) 72.93  79.81  92.54  97.70  107.33  117.30  127.28 
Axial Fan Air Flow×1000m3/h 160.8 160.8 172.8 241.2 230.4 321.6 321.6
Power×Qty (KW) 1.2×12 1.2×12 2.0×12 2.0×12 1.2×16 2.0×16 2.0×16

1. Rated Cooling Capacity Based on: DB Temperature 35ºC/WB Temperature 24ºC;Chilled water in/outlet temp. 12ºC/7ºC,  Fouling factor: 0.088.°C/KW.
 2. Rated Cooling Capacity Based on: DB Temperature 7ºC/WB Temperature 6ºC;Hot water in/outlet temp. 40ºC/45ºC;  Hot water range: 45ºC~50ºC;


4.Project photos-Air source heat pump
Ce Certifcated Low Ambient Temp. Cooling and Heating Air Cooled Chiller























Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now