Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner

Product Details
Customization: Available
Type: Cabinet Air Conditioner
Capacity: 40ton
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
  • Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
  • Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
  • Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
  • Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
  • Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
  • Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
Find Similar Products

Basic Info.

Model NO.
ESSW-08DC
Indoor Machine Noise
36-49dB
Certification
CE
Cooling/Heating
Cooling/Heating
Power Source
Electrical
Power Type
AC
Condition
New
Compressor Brand
Danfoss/Copeland/SANYO/Dakin
Compressor Type
Scroll
Cooling Mode
Water Cooling
Condenser
Shell and Tube Type
Evaporator
Finned Tube Type
Controller Type
Ddc/PLC
Safety Protection
Multi Protections
Electrical Heating
Option
60Hz
Option
Structure
Galvanized Steel Sheet/PU Panel
Refrigerant
R22,R407c,R410A,R134A
Transport Package
Standard Export Packing, Such as Wooden Case.
Specification
CE Approval
Trademark
ESACIR
Origin
Guangdong, China
HS Code
841861209
Production Capacity
30~100units/Month

Product Description

1. Eurostars Water Cooling Packaged Air Conditioner/Air Conditioning Features
1) Adopt processed electrostatic powder coating of high-strength galvanized steel sheet, high-performance anti-corrosion;
 Or insulation material used PE or PU material with excellent insulation and sound-absorbing effect, non-absorbent and can effectively prevent producing cold bridge
2) Adopt Single-phase capacitance asynchronous motor, can be third gear speed to meet the different needs of air flow
3) Using thin-walled brass and the new fin, mechanical pipe up. Ensure the brass close coordination between the fins, so as to ensure the coil has the best possible effect of heat transfer, provide a reliable Protection for the efficient operation of the unit.
4) Adopt efficient centrifugal blower, low-noise, stable and reliable performance; fan and motor in conjunction with the drive shaft, bearing select high-precision imported high-quality ball bearings, no need to make up oil.
5) First effect nylon net filters or Plate type non-woven fabric filter or washable Aluminum alloy mesh in the air into the Department


2.Eurostars Water Cooling Packaged Air Conditioner/Air Conditioning Application
EUROSTARS unitary packaged air conditioners is used for purpose of air conditioning and ventilation for shops, banks, laboratories, computing centers, hotels, etc. places. Because of the package type air conditioner , it is provided ease of installation and maintenance. It has been the preferred device with the quiet and safe operation.

3.Eurostars Packaged Air Conditioning Technical Data and Photo
Model ESSW- 03SC 05SC 08DC 10DC 12SC 15TC 20DC 25DC 30TC 36TC 40QC 50QC 60FC
Technical
Parameters
Cooling Capacity KW 9.2 16.2 25.4 32.4 38.7 48.6 66.2 77.4 99.3 116.1 132.4 154.8 193.5
TR 2.6 4.6 7.2 9.2 11.0 13.8 18.8 22.0 28.2 33.0 37.7 44.0 55.0
Rated Air Flow m3/h 1500 2500 4000 5100 6200 7800 10200 12600 15300 18000 20400 25500 30000
External Static Pressure Pa 100 100 150 150 150 150 200 250 300 300 350 400 400
Power Supply 380/400/415V-3PH-50Hz
Running Power KW 2.24 3.58 5.93 7.36 9.51 10.89 15.34 19.02 23.71 28.03 31.78 39.54 51.05
Noise dB(A) ≤60 ≤62 ≤62 ≤65 ≤66 ≤67 ≤68 ≤70 ≤70 ≤73 ≤74 ≤76 ≤78

Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
4. Eurostars Packaged Air Conditioning Product Range or Series
-Ordinary floor standing type(supply air from side or supply air from top)
-Ceiling ducted type(ceiling suspended ducted)
-Purified type
-Constant temperature and humidity type(Precision air conditioner)
-Purified-constant temperature and humidity type
Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
5. Components- Packaged Air Conditioning
FRAME
--It is painted galvanized sheet steel and has very solid skeleton. Skeleton can be opened easily with double-walled, glass wool insulation fitted caps. It is painted with Stained electrostatic powder in order to be protected against foreign influences and It has a decorative appearance.
--Base made of hot dip coating box iron, frame made of anodized aluminum profiles, Paneling made of double-layer
steel plate, sandwiched with polyurethane insulation.
Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
COMPRESSOR
R407C(R410A,R134A or R22) gas hermetic scroll has compressors cooling with a very quiet and safe working. It is used for 1 , 2 or more compressors according to the capacity value. There are inlet - outlet valves and crankcase heater on the compressor.
Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
EVAPORATOR BATTERY
Direct expansion of copper pipe and aluminum fins, the surface has a high heat transmission and to provide the necessary capacity.

EVAPORATOR FAN-MOTOR GRUP
Quiet and low-speed running with a galvanized body and the rotor used in double inlet(DIDW) centrifugal belt-pulley-driven fan. Fan pressure can be adjusted .
Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
HEATING MIXER (OPTIONAL)
Copper tubes are produced in aluminum fins. As a heater, hot water and steam can be used. In addition to battery electric resistance and heat-pump system also be preferred.

AIR FILTER
It is located at the front or back. It is washable same as EU3-quality type and easily demountable. It allows to give clean air environment. It is a special filter systems for clean room applications.
Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
ELECTRICAL PANEL
Electrical panels are composed of element contactors , thermals, auto fuses, switches, signal lamps and equipped with power and control circuit. The control system is with a standard digital thermostat. Optionally ,RS 485 modem, the microprocessor control system can be selected with the building automation connectivity.

COOLING CIRCUIT ELEMENTS
DRIER : Moisture in the refrigerant circuit is Humidity is taken by cooler.
SIGHT GLASS : Fluid can be seen from the pipe.(option)
EXPANSION VAVE : Sets the cooling capacity of the evaporator
Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
SOLENOID VAVE : Room thermostat admini 's notification system provides regular work by cutting off the path of refrigerant.
LOW HIGH PRESSURE PROSESTAD : It ensures that the suction and discharge pressures within certain limits. Prostatic control is available for winter work.
DIFFERENTIAL PRESSURE SWITCH : The warning lamps get on if the belts break or filter blockage(option)
FREEZE THERMOSTAT : It protects to compressor against low evaporation temperature of the system which may occur(option)
4 WAY SOLENOID VALVE : It is used for Heat-Pump applications.
AUTOMATIC CONTROL ELEMENTS : It is placed as an option.
With Temperature and humidity panels can be made precision air-conditioning.

6.Why Choose Us?
EUROSTARS Advantages: 
1) The Proof of Quality: Now we have customers in different countries and places, such as Mexico, Australia, New Zealand, Singapore, Argentina, Middle- East, Africa…
2) The Guarantee of Quality: Reasonable design, Professional technicians, Stable production workers, Full-scale
 Equipments, Strict QA & QC system…
3) Custom-made Design: We supply our design drawing according to customer practical situation
4) Technique Support: 
 Walk in cold room: we supply our diagrammatic drawing, feel easier for installation.
 Cold storage warehouse: We have professional engineers who can go aboard to supply technology support and direction, until  turn key for our customers.
5)International Trade Operation: We have concentrated on international trade of cold storage room line for many years, accumulated various experience from different customers of different countries. So we can update our operation in time according to our customers and new rules. It is helpful to clear custom and save cost and time for our customers.
Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
7.FAQ
Q:What is packaged air conditioner?
A: A packaged air conditioner is a cooling system that has all the components covered inside one unit. Similar to a central system, the package system also connects to ductwork to distribute the chilled air to every room in the property.

Q: What information do you need to provide in order to get a quotation?
A: Generally, we need to know following items:
--Cooling Capacity in KW or RT or Btu
--Air cooling mode or water cooling mode
- -Local ambient temperature conditions
--Application
--If there are temperature and humidity requires??
--If there is filer class requires??
--Electrical power supply, such as 380V-3Phase-50HZ or 440V-3Phase-60HZ or others.
--Refrigerant:R22,R407C,R410A or R134A
If can not give full answers for above items, we can guide you through emails.

8.Customer Visit Us
Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
9.Packaged Air Conditioning Delivery or Container Loading
Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
10.Installation Instruction ,Installation Diagram or Installation Photo, Project Photos

Floor Standing Type Heating Cooling Ventilation Packaged Air Conditioner
1)Preparations
--Check construction documents related with installation; and read the installation and maintenance manual in full;
--Check if the delivered chiller is compliant with design requirements;
--Check whether all accessories are complete for field installation.
2)Limited matters
--The product should not be installed outdoor.
--The product should not be directly installed in an office space where the noise is strictly controlled; noise-proof measures should be taken.
--The AC should not be exposed under direct sunlight, or placed in a moist, corrosive, and explosive environment.
--The AC should be installed in a ventilated environment, to protect its performance and normal running.
--If the product or cooling tower is installed in low temperature environment, the company shall not be liable for any antifreeze protection.
3)Installation Location
--Check whether enough space is reserved for product maintenance is enough or not, please contact related engineers for discussion when problem is found.
--The product must be installed on concrete foundation that can bear the product operating weight, check and insure --The product foundation with sufficient strength, rigidity, levelness and stability, can not be sinking or deflecting.
Please carefully check if the actual size of the product is matched with the reserved foot hole size on foundation.

4)Water and power supply
--The installation place of product should be provided with water source available for operating requirements.
When the product is supplied with industrial water or well water, river water and other water sources, which contains a lot of HCO3-, HSO4- and other acidic salt, and may cause condenser and pipes scaling, and affect the refrigeration effects during seriously running, the water system should be designed as a circulatory system, and the water should be softened. The following water quality characteristics are applicable to the condenser hereto (Table ):
 
Items
 
Unit Water circulating quality Supplementary water quality standard
Standard values Trend
Corrosion Scaling
PH (25 ºC)   6.5~8.0 + + 6.0~8.0
Electrical conductivity (25 ºC) μS/cm <800 + + <200
Chloride ion Cl- mg/L <200 +   <50
Sulfate ions SO42- mg/L <200 +   <50
Acid consumption (PH4.8) mg/L <100   + <50
Full hardness (CaCO3) mg/L <200   + <50
Total iron (Fe) mg/L <1.0 + + <0.3
Sulfide ion S2- mg/L Undetectable +   Undetectable
Ammonium ion NH4 + mg/L <1.0 +   <0.2
Silicon dioxide SiO2 mg/L <50   + <30
 
Note: in the table, "+" indicates that over-standard values may result in corrosion and scaling.
--The installation site should be provide with power that meets the requirements on operation

Except above information, users can refer our manual for more information, such as installation steps, commissioning and operating, maintenance.