• Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller
  • Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller
  • Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller
  • Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller
  • Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller
  • Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller

Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 220~460V-50Hz/60Hz-3pH
Compressor Number: 1, 2, 4
Noise Level: Low
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ESSA Series
Application Fields
Chemical
Application Machine
Jacketed Vessels
Certification
CE
Condition
New
Expansion Valve
Danfoss, Emerson
Refrigerant
R407c, R404A
Compressor
Copeland
Cabinet
Polyurethane Coated for Anti-Corrosion
Controller
Microcomputer Control Punp
Evaporator
Plate, Shell Tube, Coil in Tank
Condenser
Aluminum Finned Copper Tube
Color
Blue White
Tank
Stainless Steel, Unpressurized
Water Pump
Centrifugal Cnp
Solenoid Valve
Optional Castel, Hongsen
Fan
Axial
Service
OEM, ODM
Transport Package
Wooden Case
Specification
Chilled liquid outlet temp.: 0, -5, -10C
Trademark
ESACIR
Origin
Shenzhen
HS Code
8418692090
Production Capacity
3000 Units Per Year

Product Description

Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller

1. Eurostars air cooled glycol chiller main components
Compressor famous branded scroll, such as Copeland
Condenser finned type condenser(hydrophilic aluminium fin is optional)
Evaporator shell and tube type, plate type, coil in tank type
Expansion valve Famous brands such as Danfoss, Emerson
Controller leading brand PLC or SCM controller (touch screen display optional)
Pump Leading brand chilled pump, such as CNP


Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller

2. Air cooled industrial glycol chiller applications
Glycol chillers are specialized refrigeration systems, and often involves the use of antifreeze. A popular application is in beverage production, wherein the food grade chemical propylene glycol is used. Propylene glycol plays a significant role in the application of a glycol chiller. For cooling in brewing, there are few processes where decreasing or maintaining temperature are important - like crash cooling a beer after fermentation, or keeping a steady temperature during fermentation (which generates heat), or cooling the wort after an initial boiling process.

3. Air cooled glycol chiller main features
(1)High Efficiency
Utilizing advanced high efficient scroll /rotary type compressor, equipping with high efficient condenser and evaporator and imported expansion valve, to realize high EER .
(2)Reliability Operation
-Multi-protection device to keep units safety operation.
-Modular system is optional for mini chiller unit
-All chiller units has passed national standard safety system test before leaving factory, to accord with national standard.
(3)Intellectualized Control System
Adopt SCM micro computer control,can operate via centralized manage system (PLC controller is optional);clients also can choose remote controller which can also indicate chiller running condition.
(4)Easy and Simply Installation and Maintenance
-Fin coil type air side heat exchanger, no need cooling tower system and machine room, can work in draughty places.
-Refrigerant and refrigeration oil are charged well before leaving factory, just connecting with inlet/outlet water pipe and power on to start running it.
- Controller interface indicating fault information directly in order to know and maintain it in time.
(5)Special Design Is Optional
-Optional for refrigerant R22, R407C ,R134a,R410a,R404a according to customer's need;
-Optional for different kinds of power supply,such
as 380/400/415V-3PH-50HZ,220~230/380/460V-3PH-60HZ;
-Customized unit is optional,such anti-corrosion,salt water heat exchanger,etc.

4. Eurostars air cooled industrial chiller protection devices
(1)Motor overload protection
Including for compressor motors, water pump motors and fan motors.
There are some situations that will cause damage to motors in an industrial chiller, such as instable voltage, ambient temperature too high which mostly caused by poor ventilation, returning water temperature too high, etc. In these cases the motor running current will get higher than its safe range, which might damage the motor if keep it working. Built in protection for overload will shut down the chiller and warn you if the motors are working unhealthily.
(2)Compressor motor overheat protection
Compressor is the heart of an industrial chiller, it reflects problem of the whole chiller unit. The situation causes compressor motor overheat includes poor ventilation, dusty condenser, refrigerant circuit blocking, lack of refrigerant, etc.
This alarm reminds you to check through the chiller unit, prevent it from burning out because of unhealthy working condition. 
(3)Discharge temperature overhigh protection
Discharge temperature overhigh normally caused by high suction temperature, high compressor motor temperature, lack of refrigerant, etc. It works as supplementary of compressor motor overheat.
(4)High&low pressure protection
High pressure normally caused by poor ventilation, dusty condenser, refrigerant circuit blocking, etc.
Low temperature caused by lack of refrigerant, system blocking and so on.
(5)Returning water overheat protection
Chiller supply cold water to cool the production process, normally the returning water temperature will be 3ºC to 8ºC higher than supplied water. If the chiller is not creating cooling energy, or the chiller capacity is not enough for the application, the temperature in the circuit will get higher and higher. This will cause damage for the production even the equipment.
While a chiller got an alarm function for returning water temperature, we can learn the situation promptly and make reaction.
(6)Low water flow/level protection
For a chiller with no open-circuit water tank, there will be a water flow switch to make sure the water circuit is working, preventing both production process and chiller unit from harmed by circuit blocking or water leaking.
(7)Phase protection
If an industrial chiller was falsely wired, motors will revert, which is a serious problem for all the motors. Phase protection will remind you to connect the power in a right way.
(8)Anti-freezing protection
This function prevents the water in the circuit from freezing, so to make sure the cooling circuit working in a healthy condition. 

5. Eurostars air cooled glycol chiller brief technical data 
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Air Cooled Chiller Unit(R407C,-5ºC)
Model      ESSA- 03ISJTY 05ISJTY 08ISJTY 10ISJTY 12ISJTY 15ISJTY
Rated Cooling Capacity KW 4.69  8.02  12.40  16.60  20.30  24.00 
USRT 1.33  2.28  3.53  4.72  5.77  6.83 
×1000 kcal/h 4.03  6.90  10.66  14.28  17.46  20.64 
Air Cooled Chiller Unit(R407C,-5ºC)
Model      ESSA- 20IDJTY 25IDJTY 30IDJTY 40IQJTY 50IQJTY 60IQJTY
Rated Cooling Capacity KW 33.20  40.6 48 66.4 81.2 96
USRT 9.44  11.55  13.65  18.89  23.09  27.30 
×1000 kcal/h 28.55  34.92  41.28  57.10  69.83  82.56 

Remarks:
(1) Rated Cooling Capacity Based on:DB Temperature 35ºC/WB Temperature 24ºC.
(2)Chilled glycol-water liquid in/outlet temp. 0ºC/-5ºC
(3)Chilled glycol-waterl iquid range: -5~5ºC; Ambient Temperature: 5ºC~43ºC.

6.Factory testing of Eurostars every chiller unit
(1)Pressurization and helium leak detection of refrigeration circuit
(2)Pressurization and leak testing of fluid circuit
(3)Chiller performance and power consumption at full load
(4)Proper operation of all controls, safety devices, and alarms
(5)Electrical tests according to standards 
Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller
 
7. What concentration of glycol is needed for freeze protection?
Glycol must be used in applications where the chiller is installed outdoors or when fluid temperatures below freezing are required. The freezing point of the water-glycol solution depends on the type and concentration of glycol, and whether or not the glycol contains inhibitors for corrosion protection. The table below provides a rough guide of the ethylene glycol concentration required for various ambient or operating temperatures. Choose a glycol concentration that results in a freezing point of several degrees below the lowest anticipated ambient or operating temperature.
Temperature (°C) 0 -5 -10 -15 -35
Temperature (°F) 32 23 14 5 -31
Ethylene glycol (% by volume) 20 30 30 40 55

8. FAQ about glycol for industrial chiller
Glycol is a very important element in any cooling system. Despite its ubiquity and its importance, most customers don't fully understand all that it does. In an effort to clear up some of the confusion about glycol, here are our answers to the most commonly asked questions.

Q: What is Glycol?
A: Glycol is a water-miscible organic compound in the alcohol family. It is commonly used for cooling in industrial and mechanical applications. Glycol is sometimes called antifreeze or a coolant. Though it acts similarly to a refrigerant, and someone may refer to glycol as a refrigerant, this statement is incorrect. Glycol cools solely through heat transfer in an exchanger; whereas, refrigerant uses an evaporation-condensation cycle to remove heat.

Q: What does glycol do in a processing cooling system?
A: The most important role glycol plays in a process cooling system is to adjust the temperature range of the system. Without any glycol in the system, the water will freeze at the normal 32°F (0°C). In this case, the system ambient temperature can never go below this temperature. However, many systems need temperature flexibility as pipes travel outside and into unheated areas. Adding glycol to the water lowers the freezing point. The percent of glycol determines what the new freezing point will be.

A lower freezing point means process fluid can be kept at colder temperatures. A greater difference between medium temperatures allows for a faster heat transfer process. Heat always travels in the direction of higher temperature to lower temperature. When a coolant with a colder temperature is used, more of the energy can be transferred from the other fluid or process to the coolant.

Q: What are the benefits of using glycol in my system?
A: Glycol often contains corrosion inhibitors which can help to prolong the life of components. Its main function is to enable a cooling system to operate at temperatures below the freezing point of water. Certain systems may require this lowered cooling for optimum performance.

Q: What percentage of glycol does my system require?
A: Deciding on the perfect glycol-water mixture is critical to your chiller's operation. You will need to consider factors such as ambient temperature, desired lowered temperature, and heat transfer rate. As there can be adverse effects on the cooling system when using glycol, the glycol concentration should be limited only to what is required for freeze protection.

Q: Are there different types of glycol?
A: Yes. There are two types of glycol commonly used for process chillers: Propylene and Ethylene Glycol. These products vary on metrics such as performance, environmental factors, and general safety. The specific needs of your process will determine which glycol type is best for your system.

Q: Is glycol safe to use around food and beverage products?
A: In general, propylene glycol is considered food grade and can be used in food and beverage operations. Most brewery applications use this type of glycol.

9. Eurostars Company Ceritifcate & Customer Visiting
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.

Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.

Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller


Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller
10. Our factory view

Modern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numerical control punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,. etc..

Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller
Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller

Chiller production at our previous location as below
Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller

11. Eurostars air cooled industrial chiller package and delivery

Our standard package is plastic film with plywood case for safe delivery and easy to load/unload.


Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller
Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller

12. Eurostars industrial chiller projects

We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..
Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller
Glycol Chiller Brine Chiller Air Cooled Chiller Industrial Water Chiller

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now