Eurostars Water Cooling Air Handing Unit

Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Corrosion Durability: Higher
Operating Voltage: 380/400 VAC
Noise Level: Low
Application Fields: HVAC
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
EST
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
CE
Condition
New
Air Handling Unit
Bule/White Panel
Motor
Jiangsheng/Siemens
Fan
Deton/Nicotra
Panel
30mm or 50mm
Heat Exchanger
Eurostars
Other Kinds of Power
400V/415V-50Hz;380V/440V/460V-60Hz
Transport Package
Standard Package
Specification
CE
Trademark
Eurostars
Origin
Guangdong, Prc
HS Code
8415909000
Production Capacity
2000PCS/Year

Product Description

1.Selling Point-Eurostars chilled water fan coil-air handling unit
a)Low Noise
b)Efficient and Energy Saving
c)Easy Operation and Installation
d)Compact Exterior
e)High quality
f)Competitive price
 
2.Product series-Eurostars chilled water fan coil-air handling unit
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modulus Air Handling Unit-multi-function air handling unit
 
3.Unit specification-air handling unit
Following is only one part of our whole air handling unit specification,please ask Eurostars salesman for other detailed specification.
Heat exchanger:4Rows
Heat exchangers:6Rows
Heat exchangers:8Rows
 
Model Air Flow Volume   Air Return  Fresh Air
Rated Air Flow Air Flow Range Pressure Cooling Capacity Heating Capacity Water Flow  Water Resistance Cooling Capacity Heating Capacity Water Flow  Water Resistance
*1000CMH Pa kW L/min kPa kW L/min kPa
EST2VC4 2 1.7~2.2 150 11.44 18.41 34.5 3 22.72 20.67 68.5 9.5
EST3VC4 3 2.2~3.4 200 13.89 22.36 41.9 3.5 33.1 30.12 99.8 11.8
EST4VC4 4 3.4~4.4 250 20.63 33.21 62.2 4.7 45.94 41.8 138.5 15.3
EST5VC4 5 4.4~5.4 250 25.74 41.44 77.6 6.2 56.48 51.39 170.3 18
EST6VC4 6 5.4~6.7 300 30.91 49.76 93.2 8.5 68.19 62.05 205.6 18.3
EST8VC4 8 6.7~8.7 300 41.26 66.42 124.4 10.5 91.55 83.31 276 18.9
EST10VC4 10 8.7~10.8 350 51.61 83.09 155.6 14.5 114.9 104.55 346.4 19.3
EST12VC4 12 10.8~13 350 62.12 100.01 187.3 15.1 140.04 127.43 422.2 19.8
EST15VC4 15 13~15.4 400 73.87 118.93 222.7 15.8 167.41 152.34 504.7 21
EST16VC4 16 15.4~16.8 400 79.61 128.17 240 16.2 175.4 159.61 528.8 21.4
EST18VC4 18 16.8~18.8 400 91.05 146.59 274.5 16.4 204.79 186.35 617.4 22.1
EST20VC4 20 18.8~21.5 500 103.6 166.79 309 16.6 237.5 216.12 708.6 22.8
EST24VC4 24 21.5~25.5 500 130 209.3 387.8 16.8 287.5 261.62 857.6 23.7
EST27VC4 27 25.5~28.5 500 149.8 241.17 446.8 17.5 328.9 299.29 981.3 24.5
EST30VC4 30 28.5~31 500 169.6 273.05 505.9 18.3 375.8 341.97 1121 25.2
EST32VC4 32 31~32.8 500 183.9 296.07 548.5 18.7 356.9 324.77 1065 25.6
EST34VC4 34 32.8~34.8 550 195.8 315.23 584 19.1 424.8 386.56 1267 26
EST36VC4 36 34.8~37.5 550 206.9 333.1 617.3 19.4 467.8 425.69 1396 26.4
EST40VC4 40 37.5~42 600 230.8 371.58 681.5 20.2 532.1 484.21 1571 27.2
EST45VC4 45 42~47 600 259 416.99 764.5 22.2 594.4 540.9 1755 30.3
EST50VC4 50 47~52 650 287.2 462.39 848.1 25 670.8 610.42 1981 34.5
EST55VC4 55 52~57 650 316.2 509.08 933.7 28.3 737.6 671.21 2178 34.4
EST60VC4 60 57~64.5 700 345.4 556.09 1020 31.7 804.4 732 2375 40.2
EST70VC4 70 64.5~75 700 402.4 647.86 1188 38.4 939.9 855.3 2775 46
 
Model Air Flow Volume   Air Return  Fresh Air
Rated Air Flow Air Flow Range Pressure Cooling Capacity Heating Capacity Water Flow  Water Resistance Cooling Capacity Heating Capacity Water Flow  Water Resistance
*1000CMH Pa kW L/min kPa kW L/min kPa
EST2VC6 2 1.7~2.2 150 15.4 24.79 46.5 3.8 31.6 28.75 95.2 12.3
EST3VC6 3 2.2~3.4 200 18.7 30.1 56.5 4.4 46 41.86 138.7 15.3
EST4VC6 4 3.4~4.4 250 27.8 44.75 83.9 6 63.9 58.14 192.5 19.8
EST5VC6 5 4.4~5.4 250 34.7 55.86 104.7 7.9 78.5 71.43 236.7 23.3
EST6VC6 6 5.4~6.7 300 41.7 67.13 125.8 10.8 94.8 86.26 285.7 23.7
EST8VC6 8 6.7~8.7 300 55.7 89.67 167.9 13.4 127.2 115.75 383.6 24.5
EST10VC6 10 8.7~10.8 350 69.7 112.21 210 18.5 159.7 145.32 481.4 25
EST12VC6 12 10.8~13 400 83.9 135.07 252.8 19.2 194.6 177.08 586.8 25.6
EST15VC6 15 13~15.4 400 99.7 160.51 300.6 20.1 232.7 211.75 701.5 27.2
EST16VC6 16 15.4~16.8 400 107.5 173.07 324 20.7 243.8 221.85 735 27.7
EST18VC6 18 16.8~18.8 400 122.9 197.86 370.5 20.9 284.6 258.98 858.1 28.6
EST20VC6 20 18.8~21.5 500 139.8 225.07 417.1 21.2 326.7 297.29 984.9 29.5
EST24VC6 24 21.5~25.5 500 175.5 282.55 523.5 21.4 395.4 359.81 1192 30.7
EST27VC6 27 25.5~28.5 500 202.2 325.54 603.1 22.3 452.5 411.77 1364 31.7
EST30VC6 30 28.5~31 500 228.9 368.52 682.9 23.3 516.8 470.28 1558.1 32.6
EST32VC6 32 31~32.8 500 248.2 399.6 740.4 23.9 490.9 446.71 1480 33.2
EST34VC6 34 32.8~34.8 550 264.3 425.52 788.4 24.4 584.3 531.71 1761.5 33.7
EST36VC6 36 34.8~37.5 550 279.3 449.67 833.3 24.7 643.4 585.49 1939.7 34.2
EST40VC6 40 37.5~42 600 311.6 501.67 920 25.8 724.3 659.11 2183.6 35.2
EST45VC6 45 42~47 600 349.6 562.85 1032.2 28.3 809.2 736.37 2439.4 39.2
EST50VC6 50 47~52 650 387.8 624.35 1144.9 31.9 913.1 830.92 2752.8 44.7
EST55VC6 55 52~57 650 426.9 687.3 1260.4 36.1 1004.1 913.73 3027.1 44.6
EST60VC6 60 57~64.5 700 466.3 750.74 1376.7 40.5 1095 996.45 3310.2 52.1
EST70VC6 70 64.5~75 700 534.2 874.5 1603.8 49 1279.5 1164.34 3857.2 59.6
 
Model Air Flow Volume   Air Return  Fresh Air
Rated Air Flow Air Flow Range Pressure Cooling Capacity Heating Capacity Water Flow  Water Resistance Cooling Capacity Heating Capacity Water Flow  Water Resistance
*1000CMH Pa kW L/min kPa kW L/min kPa
EST2VC8 2 1.7~2.2 150 19.43 31.28 58.6 4.6 37.71 34.31 113.7 14.6
EST3VC8 3 2.2~3.4 200 23.61 38.01 71.2 5.4 54.93 49.98 165.6 18.2
EST4VC8 4 3.4~4.4 250 35.06 56.44 105.7 7.3 76.25 69.38 229.9 23.6
EST5VC8 5 4.4~5.4 250 43.75 70.43 131.9 9.7 93.74 85.3 282.6 27.8
EST6VC8 6 5.4~6.7 300 52.54 84.58 158.4 13.2 113.17 102.98 341.2 28.2
EST8VC8 8 6.7~8.7 300 70.12 112.89 211.4 16.4 151.95 138.27 458.1 29.2
EST10VC8 10 8.7~10.8 350 87.73 141.24 264.5 22.6 190.73 173.56 575 29.8
EST12VC8 12 10.8~13 350 105.61 170.03 318.4 23.6 232.46 211.53 700.8 30.6
EST15VC8 15 13~15.4 400 125.55 202.13 378.5 24.7 277.9 252.88 837.8 32.4
EST16VC8 16 15.4~16.8 400 135.33 217.88 408 25.3 291.17 264.96 877.8 33
EST18VC8 18 16.8~18.8 400 154.77 249.17 466.6 25.6 339.93 309.33 1024.8 34.1
EST20VC8 20 18.8~21.5 500 174.24 280.52 525.3 25.9 390.15 355.03 1176.2 35.2
EST24VC8 24 21.5~25.5 500 218.66 352.04 659.2 26.2 472.21 429.71 1423.6 36.6
EST27VC8 27 25.5~28.5 500 251.93 405.6 759.5 27.3 540.31 491.68 1628.9 37.8
EST30VC8 30 28.5~31 500 285.26 459.26 860 28.6 586.46 533.67 1768 38.9
EST32VC8 32 31~32.8 500 309.28 497.94 932.4 29.2 617.3 561.74 1861 39.5
EST34VC8 34 32.8~34.8 550 329.32 530.2 992.8 29.8 706.77 643.16 2130.7 40.1
EST36VC8 36 34.8~37.5 550 348.09 560.42 1049.4 30.3 768.4 699.24 2316.5 40.8
EST40VC8 40 37.5~42 600 384.28 618.69 1158.5 31.6 865.02 787.16 2607.8 42
EST45VC8 45 42~47 600 431.15 694.15 1299.8 34.7 966.36 879.38 2913.3 46.8
EST50VC8 50 47~52 650 478.22 769.93 1441.7 39.1 1090.52 992.37 3287.6 53.3
EST55VC8 55 52~57 650 523.5 842.83 1578.2 44.2 1199.15 1091.22 3615.1 53.1
EST60VC8 60 57~64.5 700 575.04 925.81 1733.6 49.5 1307.76 1190.06 3942.5 62.1
EST70VC8 70 64.5~75 700 669.91 1078.55 2019.6 60 1528.01 1390.48 4606.5 71.1


4.Eurostars Quotation Remarks-Air handling unit
*1.Packing: Standard export package
*2.Delivery Day: 20 working days after deposit is confirmed
*3.Delivery term: CIF,FOB or CNF EX-Work are welcomed
*4.Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
  Or 100% Irrevocable non-transferred LC at sight
*5.Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
*6.Validity: 20 days
*7.Payment currency: USD
 
5.CERTIFICATE-- CE certificated

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now