• Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems
  • Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems
  • Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems
  • Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems
  • Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems
  • Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems

Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 220~480V-50Hz/60Hz-3pH
Compressor Number: 1, 2, 3 or 4
Noise Level: Low
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ESSA-80DTP
Application Fields
Air-Conditioning (HVAC)
Application Machine
Cooling
Certification
CE
Condition
New
Compressor
Copeland/Danfoss/Panasonic/SANYO
Working Ambient Termp.
15deg C~43deg C
Housing Material
Galvanized Steel
Throttle Unit
Expansion Valve
Evaporator
Tube in Shell Tank Type/Plate Type
Refrigerant
R407c/R410A, R134A Is Optional
Application
Cooling, Air-Conditioning (HVAC)
Structure
Monoblock Type
DC Inverter
Optional
Warranty
2 Years, 18 Months, 1 Year
Overseas Service
Available
Condenser
Blue Aluminum Fin Arround Copper Tube
OEM/ODM
Available
Power Source
Electric
Power Supply
50Hz, 60Hz(Optional)
Transport Package
Standard Export Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8418692090
Production Capacity
2000PCS/Year

Product Description

1.Application of scroll commercial air cooling water chiller
Eurostars air cooling water chiller can supply domestic/commercial room cooling. 
Wide Range of Applications: air to water water chilles could meet the space cooling requirements of different places, such as villas, families, schools, factories, hotels, hospitals, etc.


2.Eurostars Commercial Air Cooling Scroll Water Chillers Features:
Eurostars air cooling water chillers are designed for commercial cooling. They have the following important features: 
--- Efficient and Energy-saving 
---Green and Environmental Protection
By using air source energy and electric power, there is no harmful gas being discharged during the operation of heat pumps. R410A and R407C refrigerant guarantees fluoride-free emission. 
---All-weather Operation
Stable operation without being influenced by windy, rainy or snowy weather. 
---Endurable 
Copeland or other famous brand scroll compressor, famous brand electronic expansion valve, Eaton/ Schneider/FUJI AC contactor and thermal relay as well as other brand components of the water chiller guarantee high product quality and a long lifespan. All of our screws and clips (both external and internal) are rust resistant , stainless steel is optional. The cabinet we are using is made of galvanized steel, making the product more rust resistant and durable.
 ---Multiple Protections
Eurostars water chiller with multiple protections: For example, if water flow is not enough in the system, the system will show high pressure protection and stop the water chiller automatically to protect the compressor from being damaged. Also, there is high current protection: if the power supply is not stable, the chiller will show the high current error to stop the heat pump and avoid compressor damage.
---Guaranteed Safety
Complete isolation of water and electricity avoids electric shock, explosion and poisoning. 
---Convenient: 
Air cooling water chillers are easy to install.


3.Air Cooled Scroll Commercial Water Chiller Technical Datas
Air Cooled Chiller Unit(commerical type)
Model      ESSA- 05STN 10DTN 12DTN 20QTN 25QTN 20DTN 25DTN
Rated Cooling Capacity KW 14 28 34.5 58.2 66 58 67
USRT 4.0 8.0 9.8 16.6 18.8 16.5 19.1
×1000 kcal/h 12.0 24.1 29.7 50.1 56.8 49.9 57.6
Refrigerant R407C
Evaporator Tank Tube in Shell  Shell and Tube
Condenser Ripple Aluminum Fins around Cooper Pipe
                   
Model      ESSA- 25DTP 40QTN 50QTP 80DTP 100QTP 160QTP
Rated Cooling Capacity KW 66 106 130 230 290 460
USRT 18.8 30.1 37.0 65.4 82.5 130.8
×1000 kcal/h 56.8 91.2 111.8 197.8 249.4 395.6
Refrigerant R410A R407C R410A
Evaporator Shell and Tube 
Condenser Ripple Aluminum Fins around Cooper Pipe

4.Air Cooled Scroll Water Chiller Main Components Introduction
(1)High Efficiency Scroll Type Compressor
---Flexible high-efficiency scroll compressor, which patent flexible design provides best ability of fluid-attack resistance and impurity tolerance.
---Continuous compression output ensure the pulse of air flow to be reduced, with low vibration noise
Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems

(2)High Efficiency Air Side Heat Exchanger
---Special shaped design, inner grooved patent sawtooth design and aluminum fin guarantee efficient heat exchange between the air side exchanger and ambient air.
(3)High Efficiency Water Side Heat Exchanger
---Tube in shell tank type: Optimize design of both inner and outer screwed tube, it helps to increase heating exchange efficiency, and provide better heating capacity. The special design of liquid refrigerant circulating tube on the bottom of condenser ensures the heat pump system run smoothly in severe working condition.
---Brazed-plate evaporator made from stainless steel features a brand-new diagonal design to better utilize heat exchanging surfaces.
---Shell and tube evaporator with inner grooved cooper tubes optimizes the cooling and heating efficiency.
Self-cleaning,high intensity,anti-shaking design and heat insulation covering material ensure shell and tube heat exchanger unstained,reliable,quiet,highly efficient.
Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems

(4)Throttling Device
Adopt superior quality famous exterior balanced thermal expansion valve or capillary type throttling device, which is high reliability and adjustability, can realize precise refrigerant and temperature control to ensure operating in precise and reliable status.
Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems

(5)Axial fan
Adopt famous brand axial fan,compact structure,which is accord with aerodynamic principles; falciform impeller which can assure it runs with high efficiency and low noise,also can keep a better aerodynamic performance even under a short air inlet condition.
(6)Intellectualized Controller
Adopt micro computer control, can operate via centralized manage system; whole system can realize remote operation. The system can monitor the water temperature, capacity status while running. The water temperature can be controlled according to the water outlet temperature.
Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems

5. EUROSTARS Commercial Air Coooling Scroll Water Chiller Series

Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems
6.About US
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services; which be always here to provide following service:
1) Project system design;
2) Technical support;
3) Manufacturing production;
4) Delivery;
5) Installation;
6) Test and commissioning;
7) Repair and maintenance;
8) After sale service, etc


Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems
7.FAQ
Q: What kind of Technical support Eurostars can provide?
Before selling
1. Set up customers file, and arrange professional sale engineers to introduce company products and services to customers in detail.
2. If customers are interested in our products, we will send professional technicians to survey the installation environment.
3. Make the solution according to different customers' requirements.

During selling
1. Machine installs and test by qualification engineers.
2. Ensure all the products we provided are qualified and new. The working life of the main engine is 15-20 years.
3. Construct and install the heat pump according to national relevant policies strictly, and ensure high quality delivery on time.
4. Test and debug the equipments strictly to ensure the safety and stability.
5. During the delivery, provide comprehensive and professional technical training on instructions and maintenance to customers.

After selling
1. We promise to offer free consulting call in 7×24 hours mode to solve the problems found in practice.
2. Products guarantee is 12~18 months from ex-factory date. Within 18months,if any components of your products damaged because of quality, we supply new replacement for free.
3. After the expiration of the quality assurance, we will continue to provide lifelong maintenance services, with just charging some cost price.


8.Customer visit us
Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems
9.Air cooled water chiller delivery or container loading
Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems

10. Installation instruction or installation photo, project photos

Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems

A,Place selection of installation Heat pump

 1). Heat pump should be installed in a large space, and have good air flow condition.
 2). Air inlet and outlet must be a clear road, the distance from barrier to inlet and outlet must be longer than 2m.
 3). Set drain ditch or drain outlet, so that can drain water easily.
 4). The installation base or bracket must be firm, make sure heat pump work balancely.
 5). Make sure heat pump is vertical, can't be slanted.
 6). Don't install heat pump at the place in where there is plenty of pollutional and corrosive gas or sand or fallen leaves.
 7). The installation place can't be near inflammable, flammable thing or fire.
 8). Installation:
---The installation base can be concrete construction, or steel bracket, and must use anti-vibration rubber pad, And the surface should be smooth.
---The design of installation base can be according to heat pump weight.
---The heat pump bottom should be fixed by bolt.
B,Pipe connection
The drain pipe and overflow pipe should be installed near drain ditch or drain outlet, easy to drain, and install drain water valve on drain pipe before magnetic valve there should be service valve on water pipe.
 If use plastic pipe (such as PPR pipe or ABS pipe), users should consider pipe expand and contract problem between heat pump and water tank.
 Water supply valve and cut-off valve maybe need insulation (according to local weather condition),avoid frost crack.
C,Water pipe system installation
Water pipe should be straight, and the arrange should be reasonable, reduce bend as little as possible. Reduce the water pipe resistance.
There can't be leaking at any place of pipe.
After all equipments and pipes installation finished, users should test water pressure, and drive air out, drain dirty out, make sure water cycle system is  clean. After confirm there is not any problem, then insulate all hot water pipes.
D,Power supply wiring
 220V heat pump use single phase power supply, 380V heat pump use three phase power supply, wire line is 3phase 4lines, A B C connects live line, N connects null line, E connect earth. Be sure not to connect N line to live line of power supply.
 1).When repairing, please turn power supply at "off" side.
 2).Power supply connecting process:make sure a equipment power supply is cut off before its installation is finished. Install power supply switch at suitable place, Use rubber hole for wiring line in electric box.
Power supply demand:
220V rated voltage±10%
380V rated voltage±10%
frequency:50Hz rated frequency±2%
 3).if power supply fluctuation is out of demand, please don't start your heat pump.

Industrial Commercial Water / Air Cooled Chiller / Conditioner Cooling Systems

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now