Industrial Air Conditioners Fan Coil Units Ceiling Exposed Installation
1. Ceiling exposed floor standing fan coil brief introduction
Fan coil unit is the terminal of central air conditioning system.It consists of centrifugal fan and copper tube heat exchanger. The ceiling suspended exposed fan coil unit can be floor standing installation with supporting legs, and suitable for those places that required delicate decoration. Only exposing air outlet, which save space and easy maintenance. Widely used in hotels, restaurants, factories, hospitals, exhibition hall, shopping malls, office rooms and other industrial and civil construction of the combined air-conditioning system to meet the cooling, heating and other requirements.
Product name |
Ceiling or floor fan coil unit |
Cooling capacity |
1.8-12.6kW |
Heating capacity |
2.7-18.9kW |
DB/WB |
27ºC / 19.5ºC |
Model |
EST200VE2~EST1400VE2 |
Airflow |
200-1400 CFM |
Fan type |
Centrifugal |
Funtion |
Heat pump or chiller terminals |
Pipe configuration |
2 pipe system, 4 pipe system |
2. Ceiling exposed fan coil unit main components
(1) Fan
Fans are double inlets multi-blade centrifugal type. All fans are statically and dynamically balanced.
(2) Motor
Single-phase motors are suitable for different voltages, such as 110V, 115V, 120V, 220V, 230V, 240V. All motors have 10 percent voltage utilization range and wired to unit terminal box. Motors are designed for long life.
(3) Drain pan
Drain tray is made of plastic with hollow inside L shape and cover the entire coil.
(4) Water coil
Coils are standard design together with rows. High efficient hydrophilic aluminum fins are mechanically bonded to seamless copper tubes. All coils are specifically designed and circuited for water use. All coils are tested at 3.3MPa.
(5) Casing
Casing are constructed of heavy gauge steel. Air outlet grille and return air grille is ABS material for easy maintenance.
Units are furnished as standard with a 1 inch duct collar to facilitate connection of the supply air duct.
(6) Return air plenum
The fan coil unit shall be factory installed return air plenum that encloses the fan section of the unit. No field fabrication is required. The return air arrangement is adaptable between bottom or front return of the plenum.
(7) Washable filter
Filter should be accessible from return air grille.
3. Ceiling exposed floor standing fan coil features
(1) Excellent performance
Air flow capacities from 200 to 1400 CFM, 2-pipe or 4-pipe system combinations, economical, 3-speed fans deliver the right amount of conditioned air for comfort needs at any load.
(2) High reliability
Coils are factory leak tested at 3.3MPa air pressure with coil submerged in water. Base units are CE certified for European standards. Unit casing meets requirements for flame and smoke generation.
(3) Easy maintenance
Removable panels make access to components and connections easy. Cleanable filters available.
Label information adhered to each unit includes model, cooling capacity, electrical information.
(4) Simple installation
Piping, drain and wiring connections are readily accessible. Predrilled mounting holes and slots.
Compact unit casing accommodates installation in reduced ceiling plenum space.
4. Eurostars Fan coil unit series
1 |
Ceiling concealed fan coil unit |
2 |
High ESP ducted fan coil unit |
3 |
Universal concealed fan coil unit |
4 |
Floor standing exposed fan coil unit |
5 |
Ultra thin exposed fan coil unit |
6 |
Ceiling exposed fan coil unit |
7 |
Ceiling cassette fan coil unit |
8 |
Ceiling exposed & floor standing fan coil unit |
9 |
Wall mounted fan coil unit |
5. Ceiling floor standing exposed fan coil unit specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Universal Exposed Fan Coil Unit(2 pipe system) |
Model EST |
200HE2 |
300HE2 |
400HE2 |
500HE2 |
600HE2 |
800HE2 |
1000HE2 |
1200HE2 |
1400HE2 |
200VE2 |
300VE2 |
400VE2 |
500VE2 |
600VE2 |
800VE2 |
1000VE2 |
1200VE2 |
1400VE2 |
Power supply |
220V/1PH/50HZ |
Air flow
(m3/h) |
H |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
M |
260 |
390 |
510 |
640 |
770 |
1020 |
1280 |
1530 |
1790 |
L |
170 |
260 |
340 |
430 |
510 |
680 |
850 |
1020 |
1190 |
Cooling capacity |
TH |
H |
W |
1800 |
2700 |
3600 |
4500 |
5400 |
7200 |
9000 |
10800 |
12600 |
SH |
W |
1368 |
2052 |
2736 |
3420 |
4103 |
5471 |
6839 |
8207 |
9575 |
TH |
M |
W |
1494 |
2242 |
2989 |
3736 |
4483 |
5978 |
7472 |
8967 |
10461 |
SH |
W |
1181 |
1771 |
2362 |
2952 |
3541 |
4722 |
5903 |
7084 |
8265 |
TH |
L |
W |
1162 |
1744 |
2325 |
2906 |
3487 |
4649 |
5812 |
6974 |
8136 |
SH |
W |
953 |
1430 |
1907 |
2383 |
2860 |
3813 |
4765 |
5718 |
6672 |
Heating capacity |
H |
W |
2700 |
4050 |
5400 |
6750 |
8100 |
10800 |
13500 |
16200 |
18900 |
M |
W |
2131 |
3197 |
4262 |
5328 |
6393 |
8524 |
10655 |
12786 |
14917 |
L |
W |
1675 |
2511 |
3349 |
4186 |
5024 |
6697 |
8372 |
10046 |
11721 |
Universal Exposed Fan Coil Unit(4 pipe system) |
Model EST |
200HE4 |
300HE4 |
400HE4 |
500HE4 |
600HE4 |
800HE4 |
1000HE4 |
1200HE4 |
1400HE4 |
200VE4 |
300VE4 |
400VE4 |
500VE4 |
600VE4 |
800VE4 |
1000VE4 |
1200VE4 |
1400VE4 |
Power supply |
220V/1PH/50HZ |
Air flow
(m3/h) |
H |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
M |
260 |
390 |
510 |
640 |
770 |
1020 |
1280 |
1530 |
1790 |
L |
170 |
260 |
340 |
430 |
510 |
680 |
850 |
1020 |
1190 |
Cooling capacity |
TH |
H |
W |
1800 |
2700 |
3600 |
4500 |
5400 |
7200 |
9000 |
10800 |
12600 |
SH |
W |
1368 |
2052 |
2736 |
3420 |
4103 |
5471 |
6839 |
8207 |
9575 |
TH |
M |
W |
1494 |
2242 |
2989 |
3736 |
4483 |
5978 |
7472 |
8967 |
10461 |
SH |
W |
1181 |
1771 |
2362 |
2952 |
3541 |
4722 |
5903 |
7084 |
8265 |
TH |
L |
W |
1162 |
1744 |
2325 |
2906 |
3487 |
4649 |
5812 |
6974 |
8136 |
SH |
W |
953 |
1430 |
1907 |
2383 |
2860 |
3813 |
4765 |
5718 |
6672 |
Heating capacity |
H |
W |
1300 |
1940 |
2590 |
3240 |
3890 |
5180 |
6480 |
7780 |
9070 |
M |
W |
1020 |
1530 |
2040 |
2550 |
3060 |
4070 |
5090 |
6110 |
7130 |
L |
W |
820 |
1230 |
1630 |
2040 |
2450 |
3270 |
4080 |
4900 |
5720 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
6.Why choose EUROSTARS?
(1)With more certificate
(2) Professional team with over more than 10 years industry knowledge
(3) Oversea installation.
(4) Customer-made accepted.
(5) Diamond member of Made-In-China
(6) Audited supplier by SGS
7. Our fan coil production line
Every fan coil has strict production process, including assembly, testing, packing.
8. Our service and Customer visit
Pre-Sales Service
(1) Inquiry and consulting support.
(2) Sample testing support.
(3) View our Factory.
After-Sales Service
(1)Provide customers with installation and commissioning online instructions. And we also provide local whole project installation.
(2) Well-trained engineers available to overseas service.
(3) Worldwide agents and after-sale service available.
9. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
10. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..