Model NO.
EST3CD4
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Air-Conditioning (HVAC)System
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
ISO, CE
Condition
New
Ahu Construction
25mm/ 50mm/ 75mm Double Skin
Ahu Framework
Aluminum
Ahu Panels
Painted Steel, Gi, Ss Panels
Cooling/ Heating Coil 1
Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr
Cooling/ Heating Coil 2
Copper Tube with Copper Fins (Cu/Cu), Gi/SUS Frame
PU Foam Insulation
43-48kg/M3
Fan
Belt Drive Centrifugal Fans or Hygiene Plug Fan
Control
Option for PLC, Ddc
Base
C-Channel Hot DIP Base
Filters
Pre-Filter, Bag Filter, HEPA Filter
Cold Bridge Free Design
Yes
Side Sliding Filter with Tracks
Yes
Optional 1
VSD, VFD
Optional 2
Heat Recovery Wheel
Optional 3
Ep, Chemical Filter, Plasma Sterilizer, Ak
Transport Package
Standard Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8415830000
Production Capacity
2000pieces/Year

Product Description

1. Eurostars air handling unit and air handler features
1) 25mm/ 50mm/ 75mm Double Skin Construction;
2) Aluminum Framework;
3) Painted Steel, GI, SS Panels;
4) Modular Sections Configuration;
5) Cold Bridge Free Design;
6) Air-tightness GB/T14294-93Standard;
7) PU Foam Insulation 43-48kg/m3;
8) Pre-Filter, Bag Filter, HEPA Filter;
9) Side Sliding Filter with Tracks;
10) Multi-coils Design;
11) Double Seal Inspection Doors;
12) Quiet Belt Drive Centrifugal Fans or Hygiene Plug Fan;
13) Option for PLC, DDC control;
14) C-Channel Base;
15) Option for VSD;
16) Option for heat recovery wheel.
17) Option for EP,Chemical filter, Plasma Sterilizer, AK.


2.Eurostars Air handler,air handling unit, ahu application
Eurostars air handlers widely used in stadium, exhibition centers, airport, large station, as well as in all kinds of factories, such as car, electronics, textile, medicine, tobacco, alternator, and precise instrument. 


3.Air handler technical data, Assembly drawing diagram and photo
Ceiling Ducted Air Handling Unit(Return Air Condition-4 Rows)
Model Air Flow   Total
Pressure
Power Input Return Air
Cooling Capacity Heating Capacity Water Flow  Water Resistance Water inlet/outlet pipe Diameter
*1000CMH Pa kW kW L/min kPa DN
EST2CD4 2 250 0.25 12.7 17.6 36 8.8 25
EST2.5CD4 2.5 250 0.32 15.5 21.6 44.4 12.7 25
EST3CD4 3 300 0.55 18.7 26.1 53.4 19.6 32
EST4CD4 4 300 0.75 26 36.2 74.4 21.6 32
EST5CD4 5 350 1.1 32.3 44.8 92.4 17.6 40
EST6CD4 6 350 1.5 37.3 52.1 106.8 20.6 40
EST7CD4 7 350 1.5 43.9 61.3 126 28.4 50
EST8CD4 8 350 2.2 50.6 70.5 145.2 29.4 50
EST10CD4 10 350 2.2 60.4 84 172.8 21.6 50
EST12CD4 12 350 3 73 101.7 209.4 22.5 50
NOTE:
  1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC;
  2. Return air: Heaing: Air in 15ºC DB,Hot water in: 60ºC.
Ceiling Ducted Air Handling Unit(Return Air Condition-6 Rows)
Model Air Flow   Total
Pressure
Power Input Return Air
Cooling Capacity Heating Capacity Water Flow  Water Resistance Water inlet/outlet pipe Diameter
*1000CMH Pa kW kW L/min kPa DN
EST2CD6 2 250 0.25 16.9 21.8 48 10.8 25
EST2.5CD6 2.5 250 0.32 20.7 26.7 58.8 16.7 25
EST3CD6 3 300 0.55 24.3 31.5 69.6 18.6 32
EST4CD6 4 300 0.75 31.6 40.9 90.6 20.6 40
EST5CD6 5 350 1.1 39.3 50.7 112.2 30.4 40
EST6CD6 6 350 1.5 45.6 59.1 130.8 17.6 50
EST7CD6 7 350 1.5 54 69.9 154.8 21.6 50
EST8CD6 8 350 2.2 62.8 81.3 180 22.5 50
EST10CD6 10 350 2.2 78.7 101.8 225.6 30.4 50
EST12CD6 12 350 3 94.4 122.1 270.6 33.3 65
NOTE:
  1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC;
  2. Return air: Heaing: Air in 15ºC DB,Hot water in: 60ºC.
Eurostars ceiling Mounted Return Air Air Handler
4. Eurostars air handling unit , air handler range or series
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modular Modulus Air Handling Unit-multi-function air handling unit
Eurostars ceiling Mounted Return Air Air Handler

5. Components-air handling unit or air handler

Casing Panel and Insulation
• Double skin construction is provided by sandwich type panels comprising inner and outer painted steel skins and polyurethane foam with minimum 48kg/m3 density, providing a good thermal and acoustical performance
• The gasket liner between the panels and frame ensures the air leakage rate to comply with GB/T 14294 clean air conditioning requirement
• The factory painted steel sheet covered with 6 insulation coatings, complies to 500h salt spray testing, showing an excellent corrosion protection performance
Eurostars ceiling Mounted Return Air Air Handler

Frame
•Penta-post extra heavy gauge aluminum profiles and strong fiber-reinforced PE corner connection forming the structural  frame
• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation
• Thermal bridge free design, the profiles filled with polyurethane foam for insulation
• Anodizing surface treatment for profiles, corrosion-resistant
• Stainless steel frame available
Eurostars ceiling Mounted Return Air Air Handler

Famous Brand Fan and Motor
• Fan selection based on the air flow and air static requirement  is done by fan selection software
• Direct driven/ belt driven, forward curve/ backward curve centrifugal fans, and EC fan is available for option
• Nicotra, Kruger, Deton, Yilida is offered as option
• Motor is TEFC type, class F insulation and IP54 or IP55 protection, energy saving and stable operation
• Mounted on an adjustable slide for belt tension adjustment
• Variable frequency drive (VFD) motor is available
• Siemens, ABB, WEG, TECO is offered as option
Eurostars ceiling Mounted Return Air Air Handler

Vibration Eliminator
• To reduce the transmission of vibration and noise, fan and motor are installed on an independent complete base frame
• The complete base frame is isolated by deflection type spring isolators
• This unique structure not only reduce the vibration and noise, but also protect fan and motor during transportation
Eurostars ceiling Mounted Return Air Air Handler
High Efficiency Cooling and Heating Coil
• All coils calculation and selection is done by selection software to match the required conditions
• Large coil face area ensures maximum heat transfer rate
• All coils tested at 30bar pressure underwater 24 hours
• Various corrosion resistance coils for option:
-Cooper tube with cooper fins coil
 -Epoxy coated fins coil
 -Electrophoresis fins coil
-Heresite coated coil
Eurostars ceiling Mounted Return Air Air Handler
High efficiency filter
Filters are to remove particles and contaminants of various sizes from the air. The type of air filter being used will very much depend on the application of the system.
Panel Filter is a flat and rectangular in shape and provides a minimum low efficiency filtration which is acceptable to the air conditioning industry. The high velocity filter is arranged vertically whereas the low velocity filter is arranged in V shape. Typical air velocity that moves through the filters is in the range of 2-3 m/s.

HEPA Filter is very efficient and is able to achieve efficiencies up to 99.97%, removing minute particles and airborne bacteria from the air. It is usually used in clean room applications such as semiconductor production floor, operating theaters and critical processes.

Electrostatic Filter is used to remove particles from the air by using highly charged electrodes that ionized the air.
Bag Filter is able to remove dust particles and is thrown away after use.
Roll Filter is used for high velocity filtration where the used part is rolled up automatically/manually.
Eurostars ceiling Mounted Return Air Air Handler

Electrical control cabinet(optioanl)
•According to the requirements and functions of the unit to design the control console or cabinet
•Auto control each section of the unit to make sure the temperature, humidity and cleaness 
•High quality and international brand electrical elements
•DDC and PLC available

6.Why choose us?
Eurostars offers One Stop Solutions for:
•Pharmaceuticals industry
•Electronics industry
•Automobile industry
•Printing and food industry
•Commercial building
•VOC treatment and environment protection
•Indoor air quality
•Marine ventilation
Eurostars ceiling Mounted Return Air Air Handler
7.FAQ
Q:What is air handler?
A: An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system.
 
Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU. Sometimes AHUs discharge (supply) and admit (return) air directly to and from the space served without ductwork.

Small air handlers, for local use, are called terminal units, and may only include an air filter, coil, and blower; these simple terminal units are called blower coils or fan coil units.

A larger air handler that conditions 100% outside air, and no recirculated air, is known as a makeup air unit . An air handler designed for outdoor use, typically on roofs, is known as a packaged unit or rooftop unit .

Q: What information do you need to provide in order to get a quotation?
A: Generally, we need to know following items:
-Cooling Capacity in KW or RT or Btu
-Cold water conditions if available is better
- Local ambient temperature conditions
-Application
-Electrical power supply, such as 380V-3Phase-50HZ or 440V-3Phase-60HZ or others.
 
If can not give full answers for above items, we can via another way, such as room or building drawing,application,etc

8.Customer visit us
Eurostars ceiling Mounted Return Air Air Handler
9.Air handling unit,air handler delivery or container loading
Eurostars ceiling Mounted Return Air Air Handler
10.Installation instruction or installation photo, project photos
Eurostars ceiling Mounted Return Air Air Handler
---1. During installation, enough space should be reserved around the unit, especially aside the access door and water pipe, for the repair machine passing. 
---2. The unit should be mounted on flat base (concrete or welded C-channel).  Drainages are available around the base.
---3. Floor drain should be set in the machine room for the discharge of condensing water and washing water.
---4.Pay attention to condensing water discharging; to ensure the condensing water discharge smoothly.
---5. The unit should be installed on a horizontal platform or hanger.  After the unit is installed, connect the kinds of pipes and ducts:
A. The chilled water pipe connection with cooling coil;
B. The condensing water drain pipe connection;
C. Humidifier pipes connection;
D. The connection for the fresh/return air inlet with its air ducts;
E. The wiring connection for the control box.
When connecting the air duct, 100-150mm flexible connection (airtight canvas or artificial leather cloth) should be set between flange and air inlet/outlet, to avoid the air leakage caused by the unit vibration.

The control box normally is installed on the unit cabinet or in the machine room. Please make the wiring according to the related electrical regulation by your country.

---6.After all water pipe, wirings and air duct are correctly connected, the air handling unit can be started.
[ !]The first time starting should be instructed by an experienced person at site, non-experienced person can't operate the equipment without permit.  The defect caused by misuse shall not be our obligation;
[ !] Before first time starting, please remove the temporary fixing plate from the fan and motor;
[ !] The power and voltage supply must be compatible with the unit.  After connecting the power to the motor, start motor first, then check the running direction of the fan. If it is running in opposite direction, please stop and change the phase sequence, then connect the power to motor finally. If there is protection device on the supply fan motor, the motor raring should be connected to ground.  The motor in this unit use "reduced voltage starting".
---7. Adjustment of the driving belt
---8. Before moving the unit, please fasten the damping device.  Putting down should be slowly to make sure that the damping device is forced evenly to protect the damping device.  The connection between damping device and the unit should not be by welding

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier