Horizontal Concealed Fan Coil Central Air Conditioning Fan Coil Unit
1. Ceiling concealed fan coil brief description
Fan coil units are mainly composed of centrifugal fans and coil heat exchangers. It is the terminal device of the central air conditioning system. And the fan sends indoor air or outdoor mixed air through the air cooler to be cooled or heated and then sends the air into the room to lower or raise the indoor temperature to meet people's comfort requirements.
It is widely used in hotels, restaurants, factories, hospitals, exhibition gall eries, shopping malls and moving buildings.It is used to meet the requirements of cooling, dehumidification, heating and so on.
2. ESAICR Fan coil unit series
Ceiling concealed fan coil unit
High ESP ducted fan coil unit
Universal concealed fan coil unit
Floor standing exposed fan coil unit
Ultra thin exposed fan coil unit
Ceiling exposed fan coil unit
Ceiling cassette fan coil unit
Ceiling exposed & floor standing fan coil unit
Wall mounted fan coil unit
3. Ceiling concealed fan coil unit main components
(1) Fan
(2) Motor
(3) Drain pan
4) Water coil
(5)Casing
(6) Optional return air plenum and filter
4. Ceiling horizontal concealed fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Horizontal Concealed Fan Coil Unit (2 pipe system) |
Model EST~ |
200HC2 |
300HC2 |
400HC2 |
500HC2 |
600HC2 |
800HC2 |
1000HC2 |
1200HC2 |
1400HC2 |
Air flow (m3/h)
(0/12Pa,30Pa Static Pressure) |
High |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
Medium |
270 |
380 |
515 |
660 |
765 |
1040 |
1280 |
1550 |
1800 |
Low |
190 |
260 |
340 |
430 |
530 |
710 |
860 |
1050 |
1280 |
Rated cooling capacity |
H |
TH(W) |
1800 |
2700 |
3600 |
4500 |
5400 |
7200 |
9000 |
10800 |
12600 |
SH(W) |
1341 |
2012 |
2682 |
3353 |
4023 |
5364 |
6705 |
8046 |
9387 |
M |
TH(W) |
1485 |
2187 |
2916 |
3645 |
4374 |
5832 |
7290 |
8748 |
10206 |
SH(W) |
1152 |
1728 |
2304 |
2880 |
3455 |
4607 |
5759 |
6911 |
8063 |
L |
TH(W) |
1134 |
1701 |
2268 |
2835 |
3402 |
4536 |
5670 |
6804 |
7938 |
SH(W) |
930 |
1395 |
1860 |
2325 |
2790 |
3720 |
4649 |
5579 |
6509 |
Rated heating capacity |
H |
W |
2700 |
4050 |
5400 |
6750 |
8100 |
10800 |
13500 |
16200 |
18900 |
M |
2079 |
3119 |
4158 |
5198 |
6237 |
8316 |
10395 |
12474 |
14553 |
L |
1634 |
2450 |
3267 |
4084 |
4901 |
6534 |
8168 |
9801 |
11435 |
Horizontal Concealed Fan Coil Unit (4 pipe system) |
Model EST~ |
200HC4 |
300HC4 |
400HC4 |
500HC4 |
600HC4 |
800HC4 |
1000HC4 |
1200HC4 |
1400HC4 |
Air flow (m3/h)
(0/12Pa,30Pa Static Pressure) |
High |
340 |
510 |
680 |
850 |
1020 |
1360 |
1700 |
2040 |
2380 |
Medium |
270 |
380 |
515 |
660 |
765 |
1040 |
1280 |
1550 |
1800 |
Low |
190 |
260 |
340 |
430 |
530 |
710 |
860 |
1050 |
1280 |
Rated cooling capacity |
H |
TH(W) |
1800 |
2700 |
3600 |
4500 |
5400 |
7200 |
9000 |
10800 |
12600 |
SH(W) |
1341 |
2012 |
2682 |
3353 |
4023 |
5364 |
6705 |
8046 |
9387 |
M |
TH(W) |
1485 |
2187 |
2916 |
3645 |
4374 |
5832 |
7290 |
8748 |
10206 |
SH(W) |
1152 |
1728 |
2304 |
2880 |
3455 |
4607 |
5759 |
6911 |
8063 |
L |
TH(W) |
1134 |
1701 |
2268 |
2835 |
3402 |
4536 |
5670 |
6804 |
7938 |
SH(W) |
930 |
1395 |
1860 |
2325 |
2790 |
3720 |
4649 |
5579 |
6509 |
Rated heating capacity |
H |
W |
1080 |
1620 |
2160 |
2700 |
3240 |
4320 |
5400 |
6480 |
7560 |
M |
832 |
1248 |
1663 |
2079 |
2495 |
3326 |
4158 |
4990 |
5821 |
L |
654 |
980 |
1307 |
1634 |
1960 |
2614 |
3267 |
3920 |
4574 |
Remarks:
(1) Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2) Heating: Inlet air temperature DB 20°C, heating water inlet/outlet temperature 60°C/50ºC.
5.About us:
(1) With more certificate
(2) Professional team with over more than 10 years industry knowledge
(3) Oversea installation.
(4) Customer-made accepted.
(5) Diamond member of Made-In-China
(6) Audited supplier by SGS
7. How to choose the fan coil?
(1) Firstly need to know the application site, for example, hotel room generally choose ceiling concealed fan coil, restaurant generally choose ceiling cassette fan coil, it depends on site requirements.
(2) If need to calculate cooling capacity, please get the acreage data.
(3) Confirm the pipe system: 2 pipe or 4 pipe according to the cooling and heating source.
8. Our service
Before-sale services:
(1)Tell clients how to use our products and matters needing attention.
(2)Guide clients to choose the best and economic product, recover the investment within short time.
(3)Site inspection if client require.
In-sale services:
(1)Quality control must be inspect strictly.
(2)In accordance with the agrements stipulated in the contract.
After-sale services
(1)If the project needs our installation guidance, we can send our engineer and translator. We can also send customers installation video to teach them how to fix and operate with our product.
(2)Usually, our product warranty is 12 months since BL date, within this warranty period, all parts broken will be responsible for our factory.
9. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
10. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..