Indirect Air Handling Unit for Marine Air Conditioning in HVAC

Product Details
Customization: Available
Type: Air Handling Unit
Air Tube Material: Galvanized Sheet
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Terms of Payment
LC, T/T
OEM/ODM Availability
Yes
  • Indirect Air Handling Unit for Marine Air Conditioning in HVAC
  • Indirect Air Handling Unit for Marine Air Conditioning in HVAC
  • Indirect Air Handling Unit for Marine Air Conditioning in HVAC
  • Indirect Air Handling Unit for Marine Air Conditioning in HVAC
  • Indirect Air Handling Unit for Marine Air Conditioning in HVAC
  • Indirect Air Handling Unit for Marine Air Conditioning in HVAC
Find Similar Products

Basic Info.

Model NO.
EST8VC6
Corrosion Durability
Higher
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Air-Conditioning (HVAC)System
Mounting
Ceiling Mount
Lifetime
>20 years
Certification
ISO, CE
Condition
New
Ahu Construction
25mm/ 50mm/ 75mm Double Skin
Filters
Pre-Filter, Bag Filter, HEPA Filter
PU Foam Insulation
43-48kg/M3
Ahu Framework
Aluminum
Cooling/ Heating Coil 1
Copper Tube with Aluminium Fins (Cu/Al), Gi/SUS Fr
Optional 1
VSD, VFD
Side Sliding Filter with Tracks
Yes
Base
C-Channel Hot DIP Base
Fan
Belt Drive Centrifugal Fans or Hygiene Plug Fan
Ahu Panels
Painted Steel, Gi, Ss Panels
Optional 3
Ep, Chemical Filter, Plasma Sterilizer, Ak
Control
Option for PLC, Ddc
Cooling/ Heating Coil 2
Copper Tube with Copper Fins (Cu/Cu), Gi/SUS Frame
Optional 2
Heat Recovery Wheel
Cold Bridge Free Design
Yes
Transport Package
Standard Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8415830000
Production Capacity
2000pieces/Year

Product Description

1. Eurostars air handling unit and air handler features
• Vertical Fresh /Return Air Handling Unit (AHU) is designed for restaurant, mall, office, factory production lines
• Large air flow, high supply air static pressure and cooling capacity (type and capacity upon requirement)
• Large and high level condenser coil design to increase operation efficiency and energy saving
• Operation efficiency and energy saving
• Outstanding reliability and performance
• Configured flexibly, numerous options for customization


2.Eurostars Air handler,air handling unit, ahu application
Eurostars air handlers widely used in stadium, exhibition centers, airport, large station, as well as in all kinds of factories, such as car, electronics, textile, medicine, tobacco, alternator, and precise instrument. 

3.Air handler technical data, Assembly drawing diagram and photo
Vertical Air Handling Unit(Return Air Condition-4 Rows)
Model Air Flow   Total
Pressure
Power Input Return Air
Cooling Capacity Heating Capacity Water Flow  Water Resistance Water inlet/outlet pipe Diameter
*1000CMH Pa kW kW L/min kPa DN
EST3VC4 3 300 0.55 18.7 26.1 53.4 12.7 32
EST4VC4 4 300 0.75 26 36.2 74.4 14.7 32
EST5VC4 5 350 1.1 32.3 44.8 92.4 14.7 40
EST6VC4 6 350 1.5 37.3 52.1 106.8 19.6 40
EST7VC4 7 350 1.5 43.9 61.3 126 28.4 50
EST8VC4 8 350 2.2 50.6 70.5 145.2 29.4 50
EST10VC4 10 350 2.2 60.4 84 172.8 18.6 50
EST12VC4 12 400 3 73 101.7 209.4 20.6 50
EST15VC4 15 400 4 98.6 138.9 282.6 22.5 65
EST18VC4 18 400 5.5 118.3 165 339.6 24.5 65
EST21VC4 21 400 5.5 139.5 194.4 400.2 30.4 65
EST25VC4 25 400 7.5 169.5 236.3 486.6 34.3 80
Vertical Air Handling Unit(Return Air Condition-6 Rows)
Model Air Flow   Total
Pressure
Power Input Return Air
Cooling Capacity Heating Capacity Water Flow  Water Resistance Water inlet/outlet pipe Diameter
*1000CMH Pa kW kW L/min kPa DN
EST3VC6 3 300 0.55 24.3 31.5 69.6 16.7 32
EST4VC6 4 300 0.75 31.6 40.9 90.6 28.4 40
EST5VC6 5 350 1.1 39.3 50.7 112.2 30.4 40
EST6VC6 6 350 1.5 45.6 59.1 130.8 14.7 50
EST7VC6 7 350 1.5 54 69.9 154.8 17.6 50
EST8VC6 8 350 2.2 62.8 81.3 180 21.6 50
EST10VC6 10 350 2.2 78.7 101.8 225.6 33.3 50
EST12VC6 12 400 3 94.4 122.1 270.6 30.4 65
EST15VC6 15 400 4 119.3 154.4 342 38.2 65
EST18VC6 18 400 5.5 143.1 185 410.4 40.2 65
EST21VC6 21 400 5.5 167.8 217.1 480.6 41.2 80
EST25VC6 25 400 7.5 203.6 263.4 583.8 45.1 80
NOTE:
  1. Return air: Cooling: Air in 27ºC DB, 19.5ºC WB,Chilled water in/out:7ºC /12ºC;
  2. Return air: Heaing: Air in 15ºC DB,Hot water in: 60ºC.

Indirect Air Handling Unit for Marine Air Conditioning in HVAC
4. Eurostars air handling unit , air handler range or series
-Horizontal ceiling ducted air handling unit
-Horizontal concealed air handling unit
-Vertical concealed air handling unit
-Vertical exposed air handling unit
-Modular Modulus Air Handling Unit-multi-function air handling unit
Indirect Air Handling Unit for Marine Air Conditioning in HVAC
5. Components-air handling unit or air handler

Casing Panel and Insulation
• Double skin construction is provided by sandwich type panels comprising inner and outer painted steel skins and polyurethane foam with minimum 48kg/m3 density, providing a good thermal and acoustical performance
• The gasket liner between the panels and frame ensures the air leakage rate to comply with GB/T 14294 clean air conditioning requirement
• The factory painted steel sheet covered with 6 insulation coatings, complies to 500h salt spray testing, showing an excellent corrosion protection performance
Indirect Air Handling Unit for Marine Air Conditioning in HVAC
Frame
•Penta-post extra heavy gauge aluminum profiles and strong fiber-reinforced PE corner connection forming the structural  frame
• superior mechanical strength and rigidity to the unit frame and to prevent any buckling or deformation
• Thermal bridge free design, the profiles filled with polyurethane foam for insulation
• Anodizing surface treatment for profiles, corrosion-resistant
• Stainless steel frame available
Indirect Air Handling Unit for Marine Air Conditioning in HVAC
Famous Brand Blower and Motor
•Energy saving Fan with low speed and low noise
•Type: Direct driven / Belt driven
            Forward curve and backward curve
            Centrifugal fan and EC plug fan
•Brand: Nicotra, Kruger, Deton, Yilida available
•Low noise long life Motor
•Brand: Siemens, ABB and Teco available

Indirect Air Handling Unit for Marine Air Conditioning in HVAC
Shock Absorber
•High quality spring isolators 
•Protect the unit during transportation
•Guard lock for fan start up
•Eliminate shock and noise during operation

Cooling/ Heating Coil
•Large coil face area with low air speed
•Various anti-corossion coating for option, Electrophoresis and Heresite coating available
•Type: Copper tube with Aluminium fins (Cu/Al), GI/SUS frame
            Copper tube with Copper fins (Cu/Cu), GI/SUS frame
•Rows: 4R/6R(can be 2R+4R design)/8R (can be 4R+4R design)
Copper Tube Protection
•Every mounting hole filled up glass cement to prevent copper tube damage during transportation and operation
Indirect Air Handling Unit for Marine Air Conditioning in HVAC
High efficiency filter
Filters are to remove particles and contaminants of various sizes from the air. The type of air filter being used will very much depend on the application of the system.
Panel Filter is a flat and rectangular in shape and provides a minimum low efficiency filtration which is acceptable to the air conditioning industry. The high velocity filter is arranged vertically whereas the low velocity filter is arranged in V shape. Typical air velocity that moves through the filters is in the range of 2-3 m/s.

HEPA Filter is very efficient and is able to achieve efficiencies up to 99.97%, removing minute particles and airborne bacteria from the air. It is usually used in clean room applications such as semiconductor production floor, operating theaters and critical processes.

Electrostatic Filter is used to remove particles from the air by using highly charged electrodes that ionized the air.
Bag Filter is able to remove dust particles and is thrown away after use.
Roll Filter is used for high velocity filtration where the used part is rolled up automatically/manually.
Indirect Air Handling Unit for Marine Air Conditioning in HVAC
Stainless Steel Drain Pan
• Slop type design, no drain water carryover and keep the pan dry
• Avoid the micro-organisms growth inside the drain pan
Antimicrobial Drain Pan is offered as option
• SteriTouch technology Drip Pan Coating
• Antimicrobial surface
• Good exterior durability and corrosion resistance
• Excellent adhesion
• Non-toxic, comply with BS476 part 7
Indirect Air Handling Unit for Marine Air Conditioning in HVAC
Electrical control cabinet(optioanl)
•According to the requirements and functions of the unit to design the control console or cabinet
•Auto control each section of the unit to make sure the temperature, humidity and cleaness 
•High quality and international brand electrical elements
•DDC and PLC available

6.Why choose us?
Eurostars offers One Stop Solutions for:
•Pharmaceuticals industry
•Electronics industry
•Automobile industry
•Printing and food industry
•Commercial building
•VOC treatment and environment protection
•Indoor air quality
•Marine ventilation
Indirect Air Handling Unit for Marine Air Conditioning in HVAC
7.FAQ
Q:What is air handler?
A: An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning (HVAC) system.
 
Air handlers usually connect to a ductwork ventilation system that distributes the conditioned air through the building and returns it to the AHU. Sometimes AHUs discharge (supply) and admit (return) air directly to and from the space served without ductwork.

Small air handlers, for local use, are called terminal units, and may only include an air filter, coil, and blower; these simple terminal units are called blower coils or fan coil units.

A larger air handler that conditions 100% outside air, and no recirculated air, is known as a makeup air unit . An air handler designed for outdoor use, typically on roofs, is known as a packaged unit or rooftop unit .

Q: What information do you need to provide in order to get a quotation?
A: Generally, we need to know following items:
-Cooling Capacity in KW or RT or Btu
-Cold water conditions if available is better
- Local ambient temperature conditions
-Application
-Electrical power supply, such as 380V-3Phase-50HZ or 440V-3Phase-60HZ or others.
 
If can not give full answers for above items, we can via another way, such as room or building drawing,application,etc
Q: Can I have a sample for testing before ordering products?
A: Yes, you can.And you are warmly welcomed to visit our factory before PO.

Q: What is the warranty of products?
A: Warranty: 12~24 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines

8.Customer visit us
Indirect Air Handling Unit for Marine Air Conditioning in HVAC
9.Air handling unit,air handler delivery or container loading
Indirect Air Handling Unit for Marine Air Conditioning in HVAC
10.Installation instruction or installation photo, project photos
Indirect Air Handling Unit for Marine Air Conditioning in HVAC

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier