• Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater
  • Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater
  • Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater
  • Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater
  • Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater
  • Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater

Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater

Certification: ISO9001, CE
Working Medium: R407c, R410A
Heat Source Type: Air Source Heat Pump
DC Inverter: Optional
Compressor: Emerson Copeland Evi Series
Working Ambient Termp.: -25deg C~43deg C
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ESSA Series
Power Supply
50Hz, 60Hz(Optional)
Water Side Heat Exchanger
Tube in Shell Type/Plate Type(Optional)
Warranty
2 Years, 18 Months, 1 Year
Air Side Heat Exchanger
Blue Aluminum Fin Arround Copper Tube
Overseas Service
Available
Throttle Unit
Electric Expansion Valve
OEM,ODM
Available
Power Source
Electric
Housing Material
Galvanized Steel
Structure
Monoblock Type
Application
Cooling and Heating
Refrigerant
R407c, R410A(Optional)
Transport Package
Standard Export Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8418692090
Production Capacity
2000PCS/Year

Product Description

1.Application of Air Source Heat Pump
In heating, ventilation, and air conditioning (HVAC) applications, a heat pump is typically a vapor-compression refrigeration device that includes a reversing valve and optimized heat exchangers so that the direction of heat flow (thermal energy movement) may be reversed. The reversing valve switches the direction of refrigerant through the cycle and therefore the heat pump may deliver either heating or cooling to a building.


2.Eurostars Air Source Heat Pump Features:
1) EVI compressor special designed for high COP (Coefficient of Performance): 4.0 even in bad weather condition or area.  
2) Base frame and external panels made of galvanized powder coated steel                         
3) Water exchanger equipped with high efficiency tube in shell heat exchanger                         
4) Reliable compressor with R407C/R410A refrigerant                     
5) Stable water flow switch & backflow proof.                        
6) Fully sealed control box with water proof level IPX4                      
7) Intelligent microprocessor control systems                       
8) Air exchanger (fin-coil) with hydrophilic coating                      
9) Thermostatic heating element for evaporator, anti-frosting
10)Every capillary tube of SANHUA/DANFOSS/EMERSON expansion valve full-covered by silicon/soft pipe refucing buffer friction, subtle vibration from compressor/fan, keeping strong as 15-20 years working life, even longer.                          
11)No need of auxiliary electrical heating and works well even at -25 ºC~30 ºC.   
12) Lowest noise that fan motor & Copeland high efficient compressor, thermostability PE material with bond for soundproof & heat preservation.   


3. Air Source Heat Pump Technical Data
Air Source Heat Pump Unit(EVI Low Ambient Temp.Type)  (Heating&Cooling)
Model ESSA-05LHN ESSA-05LHN ESSA-05LHN ESSA-05LHN
2.5ES 3ES 4.5ES 5ES
Working mode Heating&Cooling
Power supply 220V/50HZ 380V/50HZ 220V/50HZ 380V/50HZ
Heating Air DB/WB:
7ºC/6ºC,
water In/outlet:
40
ºC/45ºC
Heating capacity (kW)  7.6 8.4 14.0 15.2
Input power(kW)  2.32 2.58 4.38 4.75
Current(A)  11.1 4.7 21.0 8.7
COP(W/W) 3.28 3.26 3.20 3.20
Water flow(m3/h) 1.7 1.9 3.1 3.4
Air: -10ºC/ ,
Water In/outlet:
40
ºC/45ºC
Heating capacity (kW)  5.32 5.88 9.8 10.64
Input power(kW)  2.20 2.45 4.16 4.51
COP(W/W) 2.41 2.40 2.36 2.36
Air: -20ºC/   ,
Water In/outlet:
40
ºC/45ºC
Heating capacity (kW)  4.0 4.4 7.4 8.0
Input power(kW)  2.09 2.33 3.95 4.29
COP(W/W) 1.91 1.89 1.86 1.86
Air: -25ºC/ ,  
Water In/outlet:
40
ºC/45ºC
Heating capacity (kW)  3.9 4.2 6.4 7
Input power(kW)  2.35 2.52 4.40 4.30
COP(W/W) 1.66 1.67 1.45 1.63
Cooling Air DB/WB:
35ºC/24ºC,
water In/outlet:
12
ºC/7ºC
Cooling capacity (kW) 6.8 7.6 12.6 13.7
Input power (kW) 2.39 2.66 4.51 4.89
Current (A) 11.4 4.8 21.6 8.9
COP(W/W) 2.86 2.84 2.79 2.80
Water flow (m3/H) 1.5 1.7 2.8 3.1
             
Model ESSA-10LHN ESSA-10LHN ESSA-10LHN ESSA-15LHN
5.5ES 7ES 2*5ES 2*7ES
Working mode Heating&Cooling
Power supply 220V/50HZ 380V/50HZ 380V/50HZ 380V/50HZ
Heating Air DB/WB:
7ºC/6ºC,
water In/outlet:
40
ºC/45ºC
Heating capacity (kW)  17.5 19.0 30.4 40.8
Input power(kW)  5.46 5.94 9.5 12.75
Current(A)  26.1 10.8 17.3 23.2
COP(W/W) 3.2 3.2 3.2 3.2
Water flow(m3/h) 3.9 4.2 6.8 9.1
Air: -10ºC/ ,
Water In/outlet:
40
ºC/45ºC
Heating capacity (kW)  12.25 13.3 21.28 28.56
Input power(kW)  5.19 5.64 9.03 12.11
COP(W/W) 2.36 2.36 2.36 2.36
Air: -20ºC/   ,
Water In/outlet:
40
ºC/45ºC
Heating capacity (kW)  9.2 10.0 16.0 21.4
Input power(kW)  4.93 5.36 8.57 11.51
COP(W/W) 1.86 1.86 1.86 1.86
Air: -25ºC/ ,  
Water In/outlet:
40
ºC/45ºC
Heating capacity (kW)  7.5 9 14 19
Input power(kW)  5.10 5.80 8.60 12.00
COP(W/W) 1.47 1.55 1.63 1.58
Cooling Air DB/WB:
35ºC/24ºC,
water In/outlet:
12
ºC/7ºC
Cooling capacity (kW) 15.8 17.1 27.4 36.7
Input power (kW) 5.62 6.12 9.79 13.13
Current (A) 26.9 11.2 17.8 23.9
COP(W/W) 2.80 2.79 2.80 2.80
Water flow (m3/H) 3.5 3.8 6.1 8.2
             
Model ESSA-20LHN ESSA-30LHN ESSA-40LHN  
4*5ES 4*7ES 4*9ES  
Working mode Heating&Cooling
Power supply 380V/50HZ 380V/50HZ 380V/50HZ  
Heating Air DB/WB:
7ºC/6ºC,
water In/outlet:
40
ºC/45ºC
Heating capacity (kW)  60.0 76.0 115  
Input power(kW)  18.7 23.76 35.9  
Current(A)  34.1 43.3 65.5  
COP(W/W) 3.21 3.20 3.20  
Water flow(m3/h) 13.4 17.0 25.7  
Air: -10ºC/ ,
Water In/outlet:
40
ºC/45ºC
Heating capacity (kW)  42 53.2 80.5  
Input power(kW)  17.77 22.57 34.11  
Current(A)  2.36 2.36 2.36  
Air: -20ºC/   ,
Water In/outlet:
40
ºC/45ºC
Heating capacity (kW)  31.5 39.9 60.4  
Input power(kW)  16.88 21.44 32.40  
Current(A)  1.87 1.86 1.86  
Air: -25ºC/ ,  
Water In/outlet:
40
ºC/45ºC
Heating capacity (kW)  28 38    
Input power(kW)  17.20 24.00    
Current(A)  1.63 1.58    
Cooling Air DB/WB:
35ºC/24ºC,
water In/outlet:
12
ºC/7ºC
Cooling capacity (kW) 54.0 68.4 103.5  
Input power (kW) 19.26 24.47 36.98  
Current (A) 35.1 44.6 67.4  
COP(W/W) 2.80 2.79 2.80  
Water flow (m3/H) 12.1 15.3 23.1  

4.Air Source Heat Pump Main Components Introduction
1)Copeland Compressor :High quality Scroll Compressor .
Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater

2)Fan: Well selected axial fan motor combined with large fan blade, which provide heavy air blow at low rotate speed, reducing vibration and noise.

3)Expansion Valve: SANHUA/Danfoss Expansion valve, with more precise control of refrigerant flow system, which optimize heat pump working capacity and efficiency under different ambient conditions.
Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater

4)High Efficient tube in shell water side heat exchanger: Optimize design of both inner and outer screwed tube, it helps to increase heating exchange efficiency, and provide better heating capacity. The special design of liquid refrigerant circulating tube on the bottom of condenser ensures the heat pump system run smoothly in severe working condition.
Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater

5)Air Side Heat exchanger: Blue hydrophilic fin and copper tube heat exchanger.
6)Outfitting both liquid-storage & gas-liquid separator: Our heat pump outfitting both liquid-storage and gas-liquid separator ensures units run smoothly in different kinds of extreme hostile environment.
7)AC contactor & Thermal relay: High quality FUJ/Schneider /EATON or other brand contactor and thermal relay can freely turn on/off more times.
8)Humanized PCB Design: Military level PCB components, intelligent controlling program reinforced a reliable operation of the heat pump unit. Special colored wiring design on the PCB provides great convenience in installation and further maintenance.
Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater

9)Noise Isolated Material: Using high quality aerial noise isolated material, noise and vibration is avoided perfectly.


5. EUROSTARS Heat Pump Range:
(1) Water source heat pump
(2) Geothermal source heat pump
(3) Air source heat pump, including swimming pool heat pump
(4) EVI air source heat pump
(5) Split heat pump
(6) DC Inverter heat pump
Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater

6.About US
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services;
One Stop Solution For Your Project:
-- Project Consultation
--Professional Customized Design & Planning
--Supply Full Set Optimum Equipment & Accessary Accordingly
--Whole Project Installation & Commissioning
--Project Running Management, Engineer and Operator Training, Turnkey
--Long Life Quality Assurance & Maintenance

Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater

7.FAQ
Q:HOW TO SELECT A HEAT PUMP?
How do users know what kind heat pump should buy? Such as air source heat pump, geothermal source heat pump, water source heat pump and swimming pool heat pump. 
A:--Air source heat pump working condition is from -25C to +43C. And the efficiency is affected by air temperature greatly. Colder weather, lower efficiency. So air source heat pump is suitable for the place where air temperature is above -25C. 
--Geothermal source heat pump is: bury pipe in the garden ground, and water in the buried pipe deliver heat from soil to heat pump, heat pump transfer heat to house or hot water. Because soil temperature changes little and about 10C all the year, so that geothermal source heat pump gives constant and high efficiency all the time. If there is enough place to bury pipe, geothermal source heat pump is the best choice. But to install geothermal source heat pump cost higher than air source heat pump.


Q:Why it can work at -25ºC?
Because of the Enhanced Vapor Injection (EVI) technology from Copeland compressor, EUROSTARS designed EVI gas piping system and controlling system, make EVI air source heat pump can work stably in the low temperature condition.

8.Customer visit us
Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater
9.Air source heat pump delivery or container loading
Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater

10.Installation instruction or installation photo, project photos

Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater

Apartment Use Heat Pump Monobloc Type Heating Cooling Water Heater



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now