• Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump
  • Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump
  • Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump
  • Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump
  • Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump
  • Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump

Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump

Certification: ISO9001, CE
Working Medium: R410A
Heat Source Type: Air Source Heat Pump
Compressor: Panasonic DC Evi
DC Inverter: Yes
Working Ambient Termp.: -25deg C~43deg C
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ESSA-05LHP(5ES)
Warranty
2 Years, 18 Months, 1 Year
Throttle Unit
Electric Expansion Valve
Housing Material
Galvanized Steel
Application
Cooling and Heating
Water Side Heat Exchanger
Tube in Shell Type/Plate Type(Optional)
Overseas Service
Available
Air Side Heat Exchanger
Blue Aluminum Fin Arround Copper Tube
Structure
Monoblock Type
OEM/ODM
Available
Power Source
Electric
Power Supply
50Hz, 60Hz(Optional)
Refrigerant
R410A
Transport Package
Standard Export Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8418692090
Production Capacity
2000PCS/Year

Product Description

1.Application of Air Source Heat Pump
Eurostars Air source heat pumps can supply domestic/commercial room heating and cooling. 
Wide Range of Applications: air to water heat pumps could meet the space heating and cooling requirements of different places, such as villas, families, schools, factories, hotels, hospitals, sauna centers, greenhouses, flower gardens, farms, etc.


2.Eurostars Air Source Heat Pump Features:
1) Twin rotary compressor with inverter control - DC inverter technology control the heat pump output according to the household's energy requirements. Low waste of power;
2) R410a refrigerant, environment friendly - Green energy, no CO2 emission;
3) Safe operation with multi-protections;
4) Electronic Expansion Value allows the accurate refrigerant go through under different working conditions;
5) Hydrophilic coating air exchanger and plate heat exchanger all available.


3. Air Source Heat Pump Technical Data
Air Source Heat Pump Unit( EVI DC Inverter Monoblock Type ) (Heating&Cooling)
Model ESSA-05LHP ESSA-05LHP ESSA-10LHP ESSA-10LHP
3ES 5ES 6ES 8ES
Working mode Heating&Cooling
Working environment temperature range  -25ºC~43ºC
Power supply 220-240V/1PH/50HZ 220-240V/1PH/50HZ 220-240V/1PH/50HZ 380-420V/3PH/50HZ
Heating Air DB/WB:
7ºC/6ºC,
water In/outlet:
30ºC/35ºC
Heating capacity (kW)  9.51 16.0 18.3 23.8
Min.~Max.(kW)  4.3~9.51 7.1~16.4 8.3~18.3 9.2~23.5
Input power(kW)  2.14 3.68 4.21 5.41
Current(A)  10.5 16 19 9
COP(W/W) 4.44 4.35 4.35 4.40
Air DB/WB:
7ºC/6ºC,
water In/outlet:
40ºC/45ºC
Heating capacity (kW)  8.9 15.0 17.2 20.5
Min.~Max.(kW)  4.1~8.9 7.1~15.4 8.1~17.2 9.2~20.5
Input power(kW)  2.5 4.33 4.96 5.98
COP(W/W) 3.58 3.47 3.47 3.43
Cooling Air DB/WB:
35ºC/24ºC,
water In/outlet:
12ºC/7ºC
Cooling capacity (kW) 7.3 12.3 14.2 17.5
Min.~Max.(kW)  3.1~7.3 5.4~12.3 6.3~14.2 7.4~17.5
Input power (kW) 2.8 4.6 5.5 6.3
EER 2.61 2.67 2.58 2.78

4.Air Source Heat Pump Main Components Introduction
1)DC EVI Compressor :High quality Panasonic DC EVI compressor
Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump
2)Fan: Well selected axial DC fan motor combined with large fan blade, which provide heavy air blow at low rotate speed, reducing vibration and noise.
Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump

Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump

3)Expansion Valve: SANHUA/Danfoss Expansion valve, with more precise control of refrigerant flow system, which optimize heat pump working capacity and efficiency under different ambient conditions.

4)High Efficient tube in shell water side heat exchanger: Optimize design of both inner and outer screwed tube, it helps to increase heating exchange efficiency, and provide better heating capacity. The special design of liquid refrigerant circulating tube on the bottom of condenser ensures the heat pump system run smoothly in severe working condition.
Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump
5)Air Side Heat exchanger: Blue hydrophilic fin and copper tube heat exchanger.
Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump

6)Outfitting both liquid-storage & gas-liquid separator: Our heat pump outfitting both liquid-storage and gas-liquid separator ensures units run smoothly in different kinds of extreme hostile environment. 
7)AC contactor & Thermal relay: High quality FUJ/Schneider /EATON or other brand contactor and thermal relay can freely turn on/off more times.

8)Humanized PCB Design: Military level PCB components, intelligent controlling program reinforced a reliable operation of the heat pump unit. Special colored wiring design on the PCB provides great convenience in installation and further maintenance.
Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump
9)Noise Isolated Material: Using high quality aerial noise isolated material, noise and vibration is avoided perfectly.


5. EUROSTARS Heat Pump Range:
(1) Water source heat pump
(2) Geothermal source heat pump
(3) Air source heat pump, including swimming pool heat pump
(4) EVI air source heat pump 
(5) Split heat pump
(6) DC Inverter heat pump
Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump

6.About US
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.

 

Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump
7.FAQ
Q:How to select heat pump for house? 
--If cool house, you can calculate the total cooling load like this: average cooling load is about 220w/m2, so the heat pump total cooling capacity should be larger than your house cooling load. 
--If you heat house, the average heating load is about 100w/m2, so the heat pump heating capacity should be larger than your house total heating capacity. 
--If you use heat pump supply hot water for shower, 3.5kw to 7kw heating capacity heat pump should be ok for a common family. If a large family, you can consider a larger model. 
--If you need both heating house and hot water, the heat pump heating capacity should be above two heating load add together.

Q:How to select heat pump for house? 

--If cool house, you can calculate the total cooling load like this: average cooling load is about 220w/m2, so the heat pump total cooling capacity should be larger than your house cooling load. 
--If you heat house, the average heating load is about 100w/m2, so the heat pump heating capacity should be larger than your house total heating capacity. 
--If you use heat pump supply hot water for shower, 3.5kw to 7kw heating capacity heat pump should be ok for a common family. If a large family, you can consider a larger model. 
--If you need both heating house and hot water, the heat pump heating capacity should be above two heating load add together.


8.Customer visit us
Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump
9.Air source heat pump delivery or container loading

Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump

10.Installation instruction or installation photo, project photos

Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump

A,Place selection of installation Heat pump

 1). Heat pump should be installed in a large space, and have good air flow condition.
 2). Air inlet and outlet must be a clear road, the distance from barrier to inlet and outlet must be longer than 2m.
 3). Set drain ditch or drain outlet, so that can drain water easily.
 4). The installation base or bracket must be firm, make sure heat pump work balancely.
 5). Make sure heat pump is vertical, can't be slanted.
 6). Don't install heat pump at the place in where there is plenty of pollutional and corrosive gas or sand or fallen leaves.
 7). The installation place can't be near inflammable, flammable thing or fire.
 8). Installation:
---The installation base can be concrete construction, or steel bracket, and must use anti-vibration rubber pad, And the surface should be smooth.
---The design of installation base can be according to heat pump weight.
---The heat pump bottom should be fixed by bolt.
B,Pipe connection
The drain pipe and overflow pipe should be installed near drain ditch or drain outlet, easy to drain, and install drain water valve on drain pipe before magnetic valve there should be service valve on water pipe.
 If use plastic pipe (such as PPR pipe or ABS pipe), users should consider pipe expand and contract problem between heat pump and water tank.
 Water supply valve and cut-off valve maybe need insulation (according to local weather condition),avoid frost crack.
C,Water pipe system installation
Water pipe should be straight, and the arrange should be reasonable, reduce bend as little as possible. Reduce the water pipe resistance.
There can't be leaking at any place of pipe.
After all equipments and pipes installation finished, users should test water pressure, and drive air out, drain dirty out, make sure water cycle system is  clean. After confirm there is not any problem, then insulate all hot water pipes.
D,Power supply wiring
 220V heat pump use single phase power supply, 380V heat pump use three phase power supply, wire line is 3phase 4lines, A B C connects live line, N connects null line, E connect earth. Be sure not to connect N line to live line of power supply.
 1).When repairing, please turn power supply at "off" side.
 2).Power supply connecting process:make sure a equipment power supply is cut off before its installation is finished. Install power supply switch at suitable place, Use rubber hole for wiring line in electric box.
Power supply demand:
220V rated voltage±10%
380V rated voltage±10%
frequency:50Hz rated frequency±2%
 3).if power supply fluctuation is out of demand, please don't start your heat pump.

Heatpump DC Floor Heating Inverter Air Source to Water Heater Heat Pump

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now