Household Air Source Heatpump with Fan Coil Unit

Certification: ISO9001, CE
Working Medium: R407c;R410A
Heat Source Type: Air Source Heat Pump
Working Ambient Termp.: -7deg C~43deg C
Power Supply: 50Hz, 60Hz(Optional)
DC Inverter: Optional
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ESSA-10HN(2*5ES)
Throttle Unit
Electric Expansion Valve
Air Side Heat Exchanger
Blue Aluminum Fin Arround Copper Tube
Water Side Heat Exchanger
Tube in Shell Type/Plate Type(Optional)
Power Source
Electric
Warranty
2 Years, 18 Months, 1 Year
Refrigerant
R407c, R410A(Optional)
Compressor
Emerson Copeland
Overseas Service
Available
OEM,ODM
Available
Housing Material
Galvanized Steel
Structure
Monoblock Type
Casing Color
Gray/ White
Transport Package
Standard Export Package
Specification
CE
Trademark
ESACIR
Origin
Guangdong, China
HS Code
8418692090
Production Capacity
2000PCS/Year

Product Description

1.Application of Air Source Heat Pump
--Heating, ventilation, and air conditioning
In heating, ventilation, and air conditioning (HVAC) applications, a heat pump is typically a vapor-compression refrigeration device that includes a reversing valve and optimized heat exchangers so that the direction of heat flow (thermal energy movement) may be reversed. The reversing valve switches the direction of refrigerant through the cycle and therefore the heat pump may deliver either heating or cooling to a building.

--Water heating
In water heating applications, a heat pump may be used to heat or preheat water for swimming pools or heating potable water for use by homes and industry. Usually heat is extracted from outdoor air and transferred to an indoor water tank.

--District heating
Heat pumps can also be used as heat supplier for district heating. Possible heat sources for such applications are 
sewage water, ambient water (like sea, lake and river water), industrial waste heatgeothermal energyflue gas, waste heat from district cooling and heat from solar heat storage.

--Industrial heating
There is a great potential to reduce the energy consumption and related greenhouse gas emissions in the industry by application of industrial heat pumps.


Household Air Source Heatpump with Fan Coil Unit
2.Eurostars Air Source Heat Pump Features:
1) Base frame and external panels are made of galvanized sheet.
2) High efficiency compressor with R407C/R410A/R134A Refrigerant.
3) Touch design LCD control panel, and the control signals are easier to be transferred to the control system;
4) Openable cabinet door design for faster and simpler checking and maintenance
5) Well heat insulation inside the unit to increase the COP.
6) Exterior rotor fan ensures lower noise and vibration
7) Lovely outlook and sharp edges reduction cabinet design
8) High quality copper tube coils constructed of thread technology
9) Automatic defrosting function included.
10) Clock & Timing on/off function.
11) General testing and operational test carried out for every unit before package in the factory.
12) With full protection functions including water flow, high/low pressure, phase order, over-current etc.
13) Big evaporator to extract more heat from the air.
14) Metal Galvanized powder coated frame
15) For low temperature area: -25ºC(optional);


3. Air Source Heat Pump Technical Data
Air Source Heat Pump Unit(Heating-Cooling)
Model ESSA-5HN ESSA-10HN ESSA-12.5HN
5ES 2*5ES 2*6ES
Working mode Heating&Cooling
Rated heating capacity Heating KW 15 30 36
Rated input power KW 4.28 8.48 10.2
Rated current A 7.8 15.5 18.5
COP  KW/KW 3.50 3.54 3.53
Rater water flow m3/h 2.58 5.16 6.192
Rated cooling capacity Cooling KW 13.5 27 32.4
Rated input power KW 4.62 9.2 11.2
EER KW/KW 2.92 2.93 2.89
Rater water flow m3/h 2.32 4.64 5.57
           
Model ESSA-20HN ESSA-25HN ESSA-40HN
4*5ES 4*6ES 4*10ES
Working mode Heating&Cooling
Rated heating capacity Heating KW 60 74 120
Rated input power KW 17.15 20.5 34
Rated current A 31.2 37.4 106
COP  KW/KW 3.50 3.61 3.53
Rater water flow m3/h 10.32 12.728 20.64
Rated cooling capacity Cooling KW 54 66 106
Rated input power KW 18.3 22.2 36
EER KW/KW 2.95 2.97 2.94
Rater water flow m3/h 9.29 11.35 18.23
Remarks: 
1.Working air temperature range:-7ºC to 43ºC
2.Rated working condition: 
Heating: air temperature (DB/WB): 7ºC/6ºC, water temperature (inlet/outlet):40ºC/45ºC;
Cooling: air temperature (DB/WB): 35ºC/24ºC, water temperature (inlet/outlet):12ºC/7ºC.

4.Air Source Heat Pump Main Components Introduction
No Name Description
1 Compressor Brand: Copeland/Panasonic
2 Air Heat exchanger Hydrophilic Aluminum foil and copper pipe with inner thread heat exchanger
3 Water Heat exchanger Type: Tube in shell, advantage: thick copper pipe, strong quality. Big diameter of water flow: small water resistance. Thread coil: large heat exchanging surface
4 Expansion valve Brand: Danfoss/Sanhua or other brand, Type: Electronic type
5 Four way valve Brand: SANHUA, most famous in China
6 Fan Blade: low noise and large air flow. Motor: Axial type, stable and large air flow
7 AC contactor Brand: EATON/FUJI/ Schneider,etc, smart action, stable quality
8 Controller LCD screen, multi protections, remote control, simple operating

Household Air Source Heatpump with Fan Coil Unit

5. EUROSTARS Heat Pump Range:

Based on the "Reverse Carnot Cycle" principle, air to water heat pump is a type of air source heat pump (ASHP), which utilizes energy from the air to generate heat and provide domestic/commercial hot water, house heating and/or cooling. At the same time, ASHPs are among the most efficient heat pumps on the market, since they consume the least energy to complete the above requirements. And they are becoming more and more popular among households and businesses with their guaranteed safety, eco-friendliness, long service life and many other advantages. The service life of an air to water heat pump can usually reach 15 to 20 years.

Eurostars is one of the leading air to water heat pump manufacturers in China, which provides several types of air to water heat pumps such as hot water heat pumps, DC inverter (monoblock & split types), EVI low temp, household, and swimming pool heat pumps.

(1) Water source heat pump
(2) Geothermal source heat pump
(3) Air source heat pump, including swimming pool heat pump
(4) EVI air source heat pump
(5) Split heat pump
(6) DC Inverter heat pump
Household Air Source Heatpump with Fan Coil Unit

6.About US
Eurostars company can provide fillowing Technical support:
Before selling
1. Set up customers file, and arrange professional sale engineers to introduce company products and services to customers in detail.
2. If customers are interested in our products, we will send professional technicians to survey the installation environment.
3. Make the solution according to different customers' requirements.

During selling
1. Machine installs and test by qualification engineers.
2. Ensure all the products we provided are qualified and new. The working life of the main engine is 15-20 years.
3. Construct and install the heat pump according to national relevant policies strictly, and ensure high quality delivery on time.
4. Test and debug the equipments strictly to ensure the safety and stability.
5. During the delivery, provide comprehensive and professional technical training on instructions and maintenance to customers.

After selling
1. We promise to offer free consulting call in 7×24 hours mode to solve the problems found in practice.
2. Products guarantee is 12~18 months from ex-factory date. Within 18months,if any components of your products damaged because of quality, we supply new replacement for free.
3. After the expiration of the quality assurance, we will continue to provide lifelong maintenance services, with just charging some cost price.
Household Air Source Heatpump with Fan Coil Unit

Household Air Source Heatpump with Fan Coil Unit

7.FAQ
Q:What is the Daily Maintenance for Heat Pump Water Heaters?
Heat pump water heaters are the automation devices, if conduct the daily maintenance when using, the working life and stability of the units will be guaranteed. 
1. We should set the outlet water temperature according to the factory settings. The best energy saving water outlet temperature is 46-52ºC.
2. The filters installed outside should be cleaned regularly to ensure the clear water quality inside the system and to prevent the breaking from the blocking.
3. All the protection devices have been set before delivery, personal adjustment is not allowed.
4. Check regularly if the connection between the power supply and the electric system is tight. If there is something wrong with the electric system, we should maintain and change it in time.
5. Don't turn on/off the units by pulling the plug directly, and check the leakage protection at regular time.
6. Check if the water compensation, safety valves and air exhausting device are in normal condition to ensure the heating capacity and operation stability..
7. Check if there is leakage existed in water pipe connection.
8. Environment outside the units should be dry and clean, and cleaning the heat exchangers every 3-6 months to ensure the heat exchange efficiency.
9. Check every part of the units to ensure there is no gas leakage and no refrigerant leakage.
10. If power off the units for a long time, it's better to discharge all the water and power off the units. Before restart the units, complete inspection is necessary.
11. If there is some noise from the units when restarting, check carefully to exclude the obstacle.
12. If there is something wrong with units and we can't solve them by ourselves, it's better to inform the after sales service of the factories.

8.Customer visit us
Household Air Source Heatpump with Fan Coil Unit
Household Air Source Heatpump with Fan Coil Unit
9.Air source heat pump delivery or container loading

Household Air Source Heatpump with Fan Coil Unit
10.Installation instruction or installation photo, project photos

Household Air Source Heatpump with Fan Coil Unit

A,Place selection of installation Heat pump
 1). Heat pump should be installed in a large space, and have good air flow condition.
 2). Air inlet and outlet must be a clear road, the distance from barrier to inlet and outlet must be longer than 2m.
 3). Set drain ditch or drain outlet, so that can drain water easily.
 4). The installation base or bracket must be firm, make sure heat pump work balancely.
 5). Make sure heat pump is vertical, can't be slanted.
 6). Don't install heat pump at the place in where there is plenty of pollutional and corrosive gas or sand or fallen leaves.
 7). The installation place can't be near inflammable, flammable thing or fire.
 8). Installation:
---The installation base can be concrete construction, or steel bracket, and must use anti-vibration rubber pad, And the surface should be smooth.
---The design of installation base can be according to heat pump weight.
---The heat pump bottom should be fixed by bolt.
B,Pipe connection
The drain pipe and overflow pipe should be installed near drain ditch or drain outlet, easy to drain, and install drain water valve on drain pipe before magnetic valve there should be service valve on water pipe.
 If use plastic pipe (such as PPR pipe or ABS pipe), users should consider pipe expand and contract problem between heat pump and water tank.
 Water supply valve and cut-off valve maybe need insulation (according to local weather condition),avoid frost crack.
C,Water pipe system installation
Water pipe should be straight, and the arrange should be reasonable, reduce bend as little as possible. Reduce the water pipe resistance.
There can't be leaking at any place of pipe.
After all equipments and pipes installation finished, users should test water pressure, and drive air out, drain dirty out, make sure water cycle system is  clean. After confirm there is not any problem, then insulate all hot water pipes.
D,Power supply wiring
 220V heat pump use single phase power supply, 380V heat pump use three phase power supply, wire line is 3phase 4lines, A B C connects live line, N connects null line, E connect earth. Be sure not to connect N line to live line of power supply.
 1).When repairing, please turn power supply at "off" side.
 2).Power supply connecting process:make sure a equipment power supply is cut off before its installation is finished. Install power supply switch at suitable place, Use rubber hole for wiring line in electric box.
Power supply demand:
220V rated voltage±10%
380V rated voltage±10%
frequency:50Hz rated frequency±2%
 3).if power supply fluctuation is out of demand, please don't start your heat pump.

Household Air Source Heatpump with Fan Coil Unit
Household Air Source Heatpump with Fan Coil Unit



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.